Recommended Earthing Method

It is your responsibility to contact a qualified electrical installer to ensure that the electrical installation is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70, latest edition, and all local codes and ordinances.

EARTHING INSTRUCTIONS

For an earthed, cord-connected dryer:

This dryer must be earthed. In the event of a malfunction or breakdown, earthing will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer uses a cord having an equipment-earthing conductor and an earthing plug. The plug must be plugged into an appropriate outlet that is properly installed and earthed in accordance with all local codes and ordinances.

For a permanently connected dryer:

This dryer must be connected to a earthed metal, permanent wiring system, or an equipment-earthing conductor must be run with the circuit conductors and connected to the equipment-earthing terminal or lead on the dryer.

WARNING: Improper connection of the equipment- earthing conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly earthed. Do not modify the plug on the power supply cord: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

SAVE THESE INSTRUCTIONS

Venting Requirements

WARNING

Fire Hazard￿

Use a heavy metal vent.￿

Do not use a plastic vent.￿

Do not use a metal foil vent.￿

Failure to follow these instructions can result in death or fire.￿

WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.

The dryer vent must not be connected into any gas vent, chimney, wall, ceiling, or a concealed space of a building, or any other vent used for venting.

Do not use an exhaust hood with a magnetic latch.

Do not install flexible metal vent in enclosed walls, ceilings or floors.

10 cm (4") heavy metal vent and clamps must be used.

Use clamps to seal all joints. Vent must not be connected or secured with screws or other fastening devices which extend into the interior of the vent. Do not use duct tape.

IMPORTANT: Observe all governing codes and ordinances.

Use a heavy metal vent. Do not use plastic or metal foil vent.

Rigid metal vent is recommended to prevent crushing and kinking.

Flexible metal vent must be fully extended and supported when the dryer is in its final position. Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance.

An exhaust hood should cap the vent to prevent rodents and insects from entering the home or business.

Exhaust hood must be at least 30.5 cm (12") from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes).

5

Image 5
Contents Rev a 8528095 Rév a Table of Contents Índice Table des matièresDryer Safety Table of ContentsRecessed Area and Closet Installation Instructions Installation RequirementsTools and Parts Location Requirements26 cm 10-1/4 Left or right side exhaust Product DimensionsElectrical Requirements Recommended Earthing Method Venting RequirementsMaximum Vent Length Vent System Length10.2 cm 4 Diameter Exhaust Hoods Rigid Metal VentStand dryer up on cardboard or hardboard Install VentworkPrepare Dryer Electrical Connection Level and Exhaust the Dryer Moving dryer to a new location? Technical SpecificationCheck Operation Seguridad DE LA Secadora ÍndicePiezas y herramientas Requisitos DE InstalaciónRequisitos de ubicación Instrucciones para la instalación empotrada o en clósetMedidas del producto Requisitos eléctricosMétodo recomendado de conexión a tierra Requisitos de ventilaciónLongitud máxima del ducto de escape Largo del sistema de ventilación1Capotas de ventilación de 10,2 cm 4 de diámetro Ducto de escape de metal rígidoPonga la secadora de pie sobre el cartón o madera dura Instalación de la ventilaciónPreparación de la secadora Conexión eléctrica Nivelación y ventilación de la secadora ¿Va a mover la secadora a otro lugar? Verifique el funcionamientoEspecificaciones técnicas Ne pas sécher darticles qui ont été précédemment Dexécuter Table DES MatieresSecurite DU SECHE-LINGE Exigences demplacement Exigences DinstallationOutillage et pièces Outils nécessairesSpécifications électriques Dimensions du produitDe branchement 35.6Instructions DE Liaison a LA Terre Exigences concernant l’évacuationLongueur maximale du conduit Longueur du système d’évacuationClapets d’évacuation Diamètre de 10,2 cm Conduit métallique rigidePréparation du sèche-linge Installation du dispositif d’évacuationRaccordement électrique Réglage de l’aplomb et évacuation du sèche-linge Rev a 8528095 Rév. a Contrôle du fonctionnementCaractéristiques techniques