Whirlpool 8528095 REV A Vent System Length, Maximum Vent Length, 10.2 cm 4 Diameter Exhaust Hoods

Page 6

If using an existing vent system, clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint. Replace any plastic or metal foil vent with rigid metal or flexible metal vent.

Plan installation to use the fewest number of elbows and turns. Avoid making 90º turns.

AB

Vent System Length

Maximum length of vent system depends upon the type of vent used, number of elbows and type of exhaust hood. The maximum length for both rigid and flexible vent is shown in the chart.

Maximum Vent Length

10.2 cm (4") Diameter Exhaust Hoods

Exhaust Air Flow

A.Better

B.Good

Allow as much room as possible when using elbows or making turns. Bend vent gradually to avoid kinking.

The vent can be routed up, down, left, right, behind the dryer or straight out the back of the dryer.

Service check: Back pressure in any exhaust system used must not exceed 15.2 mm (0.6") in water column, measured with an incline manometer at the point that exhaust vent connects to dryer.

The exhaust outlet is located at the center of the rear of the dryer.

The design of the flue system should ensure that any condensate formed when operating the appliance is either retained and subsequently evaporated or discharged. Following these installation instructions should adequately meet this requirement.

Rigid Metal Vent

No. of 90° turns

Box Hood and

Angled Hood Style

 

 

Louvered Style

 

 

0

15.8 m (52 ft.)

13.4 m (44 ft.)

 

1

13.4 m (44 ft.)

11.0 m (36 ft.)

 

2

11.0 m (36 ft.)

8.5 m (28 ft.)

 

3

8.2 m (27 ft.)

6.4 m (21 ft.)

 

4

6.1 m (20 ft.)

4.3 m (14 ft.)

 

Flexible Metal Vent

 

 

 

No. of 90° turns

Box Hood and

Angled Hood Style

 

 

Louvered Style

 

 

0

9.4 m (31 ft.)

7.0 m (23 ft.)

 

1

7.9 m (26 ft.)

5.5 m (18 ft.)

 

2

6.7 m (22 ft.)

4.3 m (14 ft.)

 

3

6.1 m (20 ft.)

3.7 m (12 ft.)

 

4

5.5 m (18 ft.)

3.0 m (10 ft.)

 

For vent systems not covered by the vent specification chart (such as multiple unit hookups, plenums, and power-assist fans), see Whirlpool Service Manual, “Exhausting Whirlpool Dryers,” Part No. LIT603197, available from your Whirlpool parts distributor.

If dryer is installed in a confined area, such as a bedroom, bathroom or closet, provision must be made for enough air for combustion and ventilation. (Check governing codes and ordinances.) See “Recessed Area and Closet Installation Instructions” in the “Location Requirements” section.

A four-inch outlet hood is preferred. However, a 6.4 cm (2¹⁄₂") outlet exhaust hood may be used. A 6.4 cm (2¹⁄₂") outlet creates greater back pressure than other hood types. For permanent installation, a stationary vent system is required.

6

Image 6
Contents Table of Contents Índice Table des matières Rev a 8528095 Rév aTable of Contents Dryer SafetyTools and Parts Installation RequirementsRecessed Area and Closet Installation Instructions Location RequirementsProduct Dimensions Electrical Requirements26 cm 10-1/4 Left or right side exhaust Venting Requirements Recommended Earthing Method10.2 cm 4 Diameter Exhaust Hoods Vent System LengthMaximum Vent Length Rigid Metal VentInstall Ventwork Prepare DryerStand dryer up on cardboard or hardboard Electrical Connection Level and Exhaust the Dryer Technical Specification Check OperationMoving dryer to a new location? Índice Seguridad DE LA SecadoraRequisitos de ubicación Requisitos DE InstalaciónPiezas y herramientas Instrucciones para la instalación empotrada o en clósetRequisitos eléctricos Medidas del productoRequisitos de ventilación Método recomendado de conexión a tierra1Capotas de ventilación de 10,2 cm 4 de diámetro Largo del sistema de ventilaciónLongitud máxima del ducto de escape Ducto de escape de metal rígidoInstalación de la ventilación Preparación de la secadoraPonga la secadora de pie sobre el cartón o madera dura Conexión eléctrica Nivelación y ventilación de la secadora Verifique el funcionamiento Especificaciones técnicas¿Va a mover la secadora a otro lugar? Table DES Matieres Securite DU SECHE-LINGENe pas sécher darticles qui ont été précédemment Dexécuter Outillage et pièces Exigences DinstallationExigences demplacement Outils nécessairesDe branchement Dimensions du produitSpécifications électriques 35.6Exigences concernant l’évacuation Instructions DE Liaison a LA TerreClapets d’évacuation Diamètre de 10,2 cm Longueur du système d’évacuationLongueur maximale du conduit Conduit métallique rigideInstallation du dispositif d’évacuation Préparation du sèche-lingeRaccordement électrique Réglage de l’aplomb et évacuation du sèche-linge Contrôle du fonctionnement Caractéristiques techniquesRev a 8528095 Rév. a