Optional modules
Priming the dispensing pumps
Use the calibration to get liquid detergent to the pumphead. Once calibration is complete run an empty program to get detergent to the machine before actually washing a load of laundry in the machine.
Dispensing calibration
The dispensing calibration is used to calculate the flow rate of each single dispensing pump.
Direct access to the dispensing calibration when the machine is turned off:
^Press and hold the 2nd control key.
^Turn the machine on at the mains.
Dispensing calibration ~ Main menu
Dispensing pump 1
Dispensing pump 2 | e |
| A |
Selections: Dispensing pump 1 to 13
After selecting a dispensing pump the display shows:
Dispensing calibration ~ Dispensing pump 1
V: 100ml | t: 0s | P: 200.0 ml/min |
0/1 S A
The dispensing amount can be adjusted in 1 ml increments from 0 to 999 ml.
^Press the control key 0/1, the dispensing hose fills. Press the 0/1 button again to stop.
^Hold the hose, of the dispensing pump to be determined, in a measuring cup.
,Avoid skin and eye contact, wear protective clothing.
^Press A to get back to the main menu.
Dispensing calibration | Main menu | |
Dispensing pump 1 |
|
|
Dispensing pump 2 |
| e |
A
^Select the dispensing pump.
Dispensing calibration | Dispensing pump 1 |
| |||
V: 100ml | t: 0s |
|
| no |
|
|
|
|
|
|
|
|
|
| 0/1 | S | A |
^The dispensing can be manually stopped by pressing the 0/1 button or it will stop automatically after 60 seconds.
^Measure the pumped amount in the measuring cup.
Dispensing calibration | Dispensing pump 1 |
| ||
V: 100ml | t: 30s |
| P: 200.0 ml/min | |
|
|
|
|
|
|
| 0/1 | S | A |
^Enter the measured amount in the "V:" field. The flow rate P is calculated by the control.
^Press S "Save" to allocate the measured values to the dispensing pump.
^Reconnect the hose.
Maintenance of the dispensing system
^Rinse the dispensing system with hot water every 2 weeks, or before shutting down the dispenser pumps for any length of time, to prevent the system from clogging.
^Rinse out the suction pipes with water.
^Place the suction pipes in a container with warm water, 104 - 122°F (40 - 50°C).
^Select each pump by using the dispensing calibration.
^Turn on each pump until the dispensing system is rinsed.
^Check the connection points, hoses and washers for leaks.
25