Electrical connection

Electrical connection U.K.

All electrical work should be carried out by a suitably qualified and competent person, in strict accordance with current national and local safety regulations (BS 7671 in the UK).

Ensure power is not supplied to the appliance until after installation work has been carried out.

The appliance is supplied with a mains cable with moulded plug ready for connection to a 230-240V mains supply. Please ensure the connection data quoted on the data plate match the household mains supply.

Connection should be made via a suitable switched socket which is easily accessible after installation.

For extra safety it is advisable to install a residual current device (RCD), with a trip current of 30 mA (in accordance with DIN VDE 0664, VDE 0100 Section 739).

Do not connect via an extension lead. Extension leads do not guarantee the required safety of the appliance (e.g. danger of overheating).

Non-rewireable plugs BS 1363

The fuse cover must be refitted when changing the fuse, and if the fuse cover is lost, the plug must not be used until a suitable replacement is obtained. The colour of the correct replacement cover is that of the coloured insert in the base of the plug, or the colour that is embossed in words on the base of the plug (as applicable to the design of plug fitted).

Replacement fuses should be ASTA approved to BS 1362 and have the correct rating. Replacement fuses and fuse covers may be purchased from your local electrical supplier.

WARNING: THIS APPLIANCE MUST BE EARTHED

41

Image 41
Contents Operating instructions For condenser tumble dryer T 7744 C Disposal of the packing material Caring for the environmentDisposal of your old appliance Energy saving tipsContents Contents Correct application Safety with childrenTechnical safety Correct use Page Accessories Control panel Operating the tumble dryerDisplay Check lightsProgrammable functions Delay startProgramme duration / Estimated time remaining Tips on drying Care symbolsBrief instructions How to dry correctlySort the laundry Turn on the tumble dryerSelect any additional options Select a programmeBefore the end of a programme Remove the laundry when the programme has finishedStart the programme Low temperature Extra options / Delay startDelay start BuzzerProgramme chart Smoothing Woollens handcareAutomatic ShirtsWarm air Cool airChanging the programme sequence Cancelling a programmeChanging a programme while it is running Interrupting a programmeTo deactivate the lock Electronic system lockTo activate the lock Emptying the condensed water container Cleaning and carePull out the container Empty the containerCleaning them whilst dry Cleaning the fluff filtersCleaning them with water Cleaning the tumble dryer Removing the condenser unit Cleaning the condenser unitChecking the condenser unit Replacing the condenser unit Check and fault messages Problem solving guideAirways indicator Problem Possible cause RemedyTo switch off the indicator Buzzer sounds To switch off the indicator LightOther problems Been cleaned Problem Possible cause Remedy Water leaks fromDryer after Condenser unit hasStart when switched on Problem Possible cause Remedy Tumble dryer fails toInterior drum Lighting does not comeChanging the lamp Future updates PC After sales serviceGuarantee Optional accessoriesFront view Installation and connectionWasher-dryer stack Rear view Installation siteTransporting the machine to its installation site Room ventilation Before moving the machine again e.g. when moving houseLevelling the machine Arranging the drain hose External condensed water outletGeneral notes External drainage via a sink or gully Installation conditions requiring a non-return valveInstallation and connection Electrical connection U.K Non-rewireable plugs BSElectrical connection Smoothing Consumption dataTechnical data Programmable functions For changing default settings Extending the range of the drying levels Programmable functionsFollow steps a to F to programme and store in memory Altering the volume of the buzzerNormal buzzer Default setting Loud buzzer Memory function Memory deactivated Default setting Memory activatedCooling down time will be ten minutes longer Extending the cooling down timeDefault setting Clean out airways indicatorKeypad tone Adjusting the dryers electronics for very soft water Alteration rights reserved/1807 Nr 737 070