Fisher & Paykel 517735 service manual Recycle, LOW Water Level LED OFF = Restart OFF

Page 38

8.4RESTART

If a problem occurs in Smartdrive, it will try to correct the problem and retry. Smartdrive will rectify any problems of a temporary nature. If there is a continuous problem Smartdrive will retry several times. This process may take up to 10 minutes depending on the type of problem. If Smartdrive still cannot resolve the problem, the fault code is displayed and Smartdrive will beep continuously. RESTART ON is the default state. This forces Smartdrive to retry when a problem occurs. While servicing Smartdrive turn

RESTART OFF. This will allow any fault in the system to show up immediately.

To enter Diagnostic Mode turn the power on at the power point and off at the console. Press and hold the WASH TEMPERATURE DOWN button then press the POWER button. Smartdrive will give 2 short beeps. Phase 3 Only press ADVANCE button once. From Diagnostic mode use the WATER LEVEL DOWN button to turn the RESTART on or off.

LOW WATER LEVEL LED OFF = RESTART OFF.

LOW WATER LEVEL LED ON = RESTART ON. (Default)

RESTART status can be easily identified when Smartdrive is first turned on -

If none of the 5 leftmost green wash progress LEDs are on, the RESTART is on.

If the 5 leftmost green wash progress LEDs are flashing, the RESTART is off.

NB. RESTART is a service aid only and should be left ON in the customer’s home. To return to normal operation, and to reset the RESTART feature to the default setting, power off Smartdrive.

8.5RECYCLE

After servicing, Smartdrive may require an extended test where Smartdrive can be left to complete a number of wash cycles. By turning on RECYCLE Smartdrive will continuously repeat the selected wash cycle until RECYCLE is turned off.

Enter Diagnostic mode as described above (RESTART). Use the WATER LEVEL UP button to turn RECYCLE on or off.

MEDIUM WATER LEVEL LED ON = RE-CYCLE ON.

MEDIUM WATER LEVEL LED OFF = RE-CYCLE OFF. (Default setting).

RECYCLE status can be easily identified when Smartdrive is first turned on: -

If the 3 rightmost rinse and spin progress LEDs are on, recycle is off.

If the 3 rightmost rinse and spin LED’s flash, recycle is on.

NB. Recycle is designed as a service aid only and should be OFF in the customer’s home. To return to normal operation, and to return recycle to the default setting, power off Smartdrive.

- 33 -

Image 38
Contents Phase 1 to 5 Smart Drive Electronic Washing MachinePhase 5 IW Phase 3 GWPhase 4 GW Phase 5 IwecoWhat PHASE, Size & Model is Your SMARTDRIVE? MW, GWTable of Contents Recycle Introduction HOW to Service SmartdriveIf Smartdrive has no Power see Section Smartdrive Servicing Quick Reference Guide Specifications ALL Terminals and Internal Parts should be Treated AS LiveRemoving Transit Restraint InstallationInstallation Inlet HosesAccessories and Spare Parts Installation Environment Water Supply TemperaturesSafety Levelling SmartdriveSmartdrive Components Electronics Systems Phase Wiring Diagram Specifications MotorMotor Controller Module Water Level Measurement Pressure SensorDisplay Module Water Valves Installation Rotor Position SensorPump Motor Specifications PumpDiagram showing the Floating Bowl Inner and Outer BowlsDetection Of Inner Bowl Float Off Point Bowl Check Lid Switch and Out of Balance Switch Lid SwitchWater Temperature Sensing Smartdrive Information Favourite cycle GW only All PhasesCustomising Wash Cycles GW only Phase 3 to 5 only Water Saver GW only Phase 3 to 5 only Delay Start GW only Phase 2 to 5 onlyAuto Water Level GW only Phase 3 to 5 only Fabric Softener Dispenser All Phases Amount of Water Used in the Water Saver RinseWash Performance Information All Phases CreasingIf Smartdrive Powers Off mid cycle Smartdrive ProblemsIf Smartdrive Appears To Have No Power Noisy FloodingLeaking Continuous Spinning or Slow Spinning Poor Wash PerformanceEarth Leakage SiphoningRadio Frequency Interference RFI It Appears Smartdrive is doing nothingOption Adjustment Mode Wash Water Temperature All PhasesRinse Options All Phases Method of Setting the Wash TemperatureEnd of Cycle Warning Beeps GW Only All Phases PhaseAuto Water Fill Level Adjustment GW only Phase Out Of Balance Recovery Adjustment GW and MW only PhaseDiagnostic Mode What WAS the Last FAULT?Test LID, OUT of BALANCE, & Size Switches To Test Pump & Water ValvesLOW Water Level LED OFF = Restart OFF RestartRecycle Medium Water Level LED on = RE-CYCLE onPage Size Setting Mode Phase 4 and 5 only Insufficient Cold Water Cold Water LED flashing User WarningsInsufficient Hot Water Hot Water LED flashing No Water Both Hot and Cold Water LEDs flashing Overloaded Product High Water LED flashingRestart and Recycle Wash Progress LEDs flashing Phase 4Phase 1 to Demonstration Mode All LEDs flashing in patterns GWC09 GWM09 GWL09 Fault CodesGWC08 GWM08 GWL08 THC08 THM08 THL08 IWM09 IWL09Phase 1 Communications Fault Smartdrive Phases 1 to 5 Fault DescriptionsPhase 1 to 5 Motor Controller Fault Primary Source Motor ControllerPrimary Source Display Module Action Phase 1 to 5 Display Module FaultPhase 1 to 5 Size Error Primary Source Display ModuleAction Phase Phase 4 toPhase 1 to 5 Thermistor Error Phase 2 toPhase 1 Pump Fault Phase 1 to 5 Pressure Sensor FaultPhase 1 to 5 Flood Protection Error Primary Source Pressure Tube28 30 xx Phase 1 Display / Motor Controller out of Sequence Phase 1 Pump Connection FaultPhase 5 IW LCD Initialisation Error Primary Source Pump ActionPhase 1 MC Reset Error Phase 1 Pump Circuit ErrorPhase 1 Brake Resistor Fault Primary Source Pump System Phase 1 to 5 Water Leak FaultPhase 1 to 5 Pump Block Error Secondary Source Mechanical ActionPrimary Source Mechanical Phase 1 to 5 Tap or Pressure Sensor Tube FaultPhase 1 to 5 Bowl Dis-Engaged Fault Primary Source SudsPhase 1 to 5 OOB Switch Fault Phase 1 to 5 Temperature Sensor FaultPhase 1 Rotor Fault Primary Source Primary Source Mechanical ActionPrimary Source Pump System Action Phase 2 to 5 Water in Bowl During SpinPhase 5 Display Fault Secondary Source Motor ControllerPrimary Source Wiring Phase 2 to 3 Bowl Dis-engaged FaultPhase 2 to 5 Hot and Cold Valve Fault Phase 2 to 5 Cold Valve FaultPhase 5 ECO Recirculation Fault See fault code Phase 2 to 5 Hot Valve FaultPhase 5 ECO Recirculation Fault Secondary Source Diverter ValveSecondary Source Motor Phase 2 to 5 Rotor Position Sensor FaultPhase 2 to 5 Motor / Motor Control Step Fail Phase 4 to 5 Bowl Check Fault Phase 4 to 5 Motor Controller FaultPhase 4 Motor Controller Fault Primary Source- PumpPhase 2 to 3 Display / Motor Controller Comms. Error Phase 5 Machine Setup ErrorPhase 1 to 5 Single Rotor Position Sensor Error Primary Source Wiring ActionPhase 1 to 4 Repetitive Current Trip Phase 1 to 5 Repetitive Rotor Position Sensor ErrorPhase 1 to 4 Single Current Trip Phase 4 Single Current Trip & Rotor Position Sensor ErrorPhase 1 to 5 Motor Stall Phase 1 to 5 Bowl Engaged During Agitate Phase 4 to 5 Brake Function Time-out Fault Phase 5 Topdeck Showing Wiring Connections Mechanical Service SectionComplete Disassembly Phase 2 Topdeck Showing Wiring Connections NB DON’T Remove the Earth Connection from the WrapperPage Page Assembly Guidelines Motor Assembly & Disassembly AssemblyPump Blockage Shaft & Bearing Removal Shaft & Bearing Assembly Page Appendix a Binary Decoding Chart 8 Bits Wash Progress LEDsImportant Note Size SettingFault Finding / Fault Codes Pump Hood Kit Part Number 479188P WM013 Pump Hood KIT January 2000 Phases 2 toWiring Connections WM51 Diagnostic Flow Chart Sept 1992- Phase 1 only Kit Lever Out of Balance & Bracket Phase 2 Part Number WM65 BIB Deflector April 1994- Phase 1 onlyWM70 Premature OUT of Balance February 1995 Phase 2 only WM80 Condensation KIT May 1996 Phase 2 & 3 only WM81 Pump Shield 5KG Smartdrive September 1996 Phases 1 toAppendix C Smarttool Appendix D Tools for Servicing Smartdrive Models Size Width Wash Load Capacity Specifications for IWIW Quick Reference Guide Compact Medium LargeIntroduction to IW Wash 1 Detergent Activating Wash Front loader type washWater Temperature Sensing Option Adjustment Mode for IW PumpOther Options Diagnostic Mode for IW Status DisplayFault Status Size Setting Mode for IW Recycle