Fisher & Paykel 517735 Primary Source Mechanical, Phase 1 to 5 Tap or Pressure Sensor Tube Fault

Page 53

The Motor Controller has recorded a water level of empty while it is agitating. The water level must have been greater than empty for Smartdrive the enter the agitate mode initially. The most likely cause of this fault is that the pressure transducer hose has been severed or fallen off during agitate. Alternatively the pressure transducer may be faulty.

Primary Source - Mechanical

Action - Check that the pressure tube is intact and has not been cut.

Secondary Source - Motor Controller. (Display Module Phase 1).

Action - Replace the Motor Controller. (Display Module Phase 1).

39.(00100111) Phase 1 to 5 – Tap or Pressure Sensor Tube Fault

During fill, the Display module has not registered a change in the water level reading for a certain length of time. It has then carried out a bowl check and found that the bowl is floating although the water level reading is below bowl float level . The probable cause of this fault is that the pressure tube has become blocked or kinked or has fallen off completely. Alternatively the pressure transducer may be faulty.

Primary Source - Mechanical

Action - Check that the pressure tube is intact and not blocked with water, dirt or kinked.

Secondary Source - Motor Controller. (Display Module Phase 1). Action - Replace Motor Controller. (Display Module Phase 1).

40.(00101000) Phase 1 to 5 - Bowl Dis-Engaged Fault

While carrying out a bowl check, the Display module has found that the bowl is not engaged even though the pressure sensor indicates that the bowl is empty. The Motor Controller continues to check for 2 minutes after which time the display this fault. If restart is on this fault can take up to 4 hours to diagnose. The first two areas to check are the clutch and the pressure tube. If these two appear correct, then the fault could be in the pressure transducer in the Motor Controller.

Primary Source - Suds

Action - Too many suds, too much detergent has been used. Restart product when suds have disappeared, or select a deep rinse option.

Secondary Source - Mechanical

Action

1.Check that there are no clothes or other foreign objects preventing the clutch from re- engaging.

2.Next check that the pressure tube has not come off and that it is not kinked.

Tertiary Source - Motor Controller. (Display Module Phase 1).

Action - Replace Motor Controller (Display Module Phase 1), if the above check out without fault.

- 48 -

Image 53
Contents Smart Drive Electronic Washing Machine Phase 1 to 5Phase 4 GW Phase 3 GWPhase 5 IW Phase 5 IwecoMW, GW What PHASE, Size & Model is Your SMARTDRIVE?Table of Contents Recycle Introduction HOW to Service SmartdriveIf Smartdrive has no Power see Section Smartdrive Servicing Quick Reference Guide ALL Terminals and Internal Parts should be Treated AS Live SpecificationsInstallation InstallationRemoving Transit Restraint Inlet HosesSafety Installation Environment Water Supply TemperaturesAccessories and Spare Parts Levelling SmartdriveSmartdrive Components Electronics Systems Phase Wiring Diagram Motor SpecificationsWater Level Measurement Pressure Sensor Motor Controller ModuleDisplay Module Water Valves Rotor Position Sensor InstallationPump Pump Motor SpecificationsInner and Outer Bowls Diagram showing the Floating BowlDetection Of Inner Bowl Float Off Point Bowl Check Lid Switch Lid Switch and Out of Balance SwitchWater Temperature Sensing Smartdrive Information Favourite cycle GW only All PhasesCustomising Wash Cycles GW only Phase 3 to 5 only Water Saver GW only Phase 3 to 5 only Delay Start GW only Phase 2 to 5 onlyAuto Water Level GW only Phase 3 to 5 only Amount of Water Used in the Water Saver Rinse Fabric Softener Dispenser All PhasesCreasing Wash Performance Information All PhasesIf Smartdrive Powers Off mid cycle Smartdrive ProblemsIf Smartdrive Appears To Have No Power Noisy FloodingLeaking Poor Wash Performance Continuous Spinning or Slow SpinningRadio Frequency Interference RFI SiphoningEarth Leakage It Appears Smartdrive is doing nothingWash Water Temperature All Phases Option Adjustment ModeMethod of Setting the Wash Temperature Rinse Options All PhasesPhase End of Cycle Warning Beeps GW Only All PhasesOut Of Balance Recovery Adjustment GW and MW only Phase Auto Water Fill Level Adjustment GW only PhaseWhat WAS the Last FAULT? Diagnostic ModeTo Test Pump & Water Valves Test LID, OUT of BALANCE, & Size SwitchesRecycle RestartLOW Water Level LED OFF = Restart OFF Medium Water Level LED on = RE-CYCLE onPage Size Setting Mode Phase 4 and 5 only Insufficient Cold Water Cold Water LED flashing User WarningsInsufficient Hot Water Hot Water LED flashing Overloaded Product High Water LED flashing No Water Both Hot and Cold Water LEDs flashingRestart and Recycle Wash Progress LEDs flashing Phase 4Phase 1 to Demonstration Mode All LEDs flashing in patterns GWC08 GWM08 GWL08 THC08 THM08 THL08 Fault CodesGWC09 GWM09 GWL09 IWM09 IWL09Phase 1 to 5 Motor Controller Fault Smartdrive Phases 1 to 5 Fault DescriptionsPhase 1 Communications Fault Primary Source Motor ControllerPhase 1 to 5 Size Error Phase 1 to 5 Display Module FaultPrimary Source Display Module Action Primary Source Display ModulePhase 1 to 5 Thermistor Error Phase 4 toAction Phase Phase 2 toPhase 1 to 5 Flood Protection Error Phase 1 to 5 Pressure Sensor FaultPhase 1 Pump Fault Primary Source Pressure TubePhase 5 IW LCD Initialisation Error Phase 1 Pump Connection Fault28 30 xx Phase 1 Display / Motor Controller out of Sequence Primary Source Pump ActionPhase 1 MC Reset Error Phase 1 Pump Circuit ErrorPhase 1 Brake Resistor Fault Phase 1 to 5 Pump Block Error Phase 1 to 5 Water Leak FaultPrimary Source Pump System Secondary Source Mechanical ActionPhase 1 to 5 Bowl Dis-Engaged Fault Phase 1 to 5 Tap or Pressure Sensor Tube FaultPrimary Source Mechanical Primary Source SudsPhase 1 Rotor Fault Primary Source Phase 1 to 5 Temperature Sensor FaultPhase 1 to 5 OOB Switch Fault Primary Source Mechanical ActionPhase 5 Display Fault Phase 2 to 5 Water in Bowl During SpinPrimary Source Pump System Action Secondary Source Motor ControllerPhase 2 to 5 Hot and Cold Valve Fault Phase 2 to 3 Bowl Dis-engaged FaultPrimary Source Wiring Phase 2 to 5 Cold Valve FaultPhase 5 ECO Recirculation Fault Phase 2 to 5 Hot Valve FaultPhase 5 ECO Recirculation Fault See fault code Secondary Source Diverter ValveSecondary Source Motor Phase 2 to 5 Rotor Position Sensor FaultPhase 2 to 5 Motor / Motor Control Step Fail Phase 4 to 5 Motor Controller Fault Phase 4 to 5 Bowl Check FaultPrimary Source- Pump Phase 4 Motor Controller FaultPhase 5 Machine Setup Error Phase 2 to 3 Display / Motor Controller Comms. ErrorPrimary Source Wiring Action Phase 1 to 5 Single Rotor Position Sensor ErrorPhase 1 to 4 Single Current Trip Phase 1 to 5 Repetitive Rotor Position Sensor ErrorPhase 1 to 4 Repetitive Current Trip Phase 4 Single Current Trip & Rotor Position Sensor ErrorPhase 1 to 5 Motor Stall Phase 1 to 5 Bowl Engaged During Agitate Phase 4 to 5 Brake Function Time-out Fault Phase 5 Topdeck Showing Wiring Connections Mechanical Service SectionComplete Disassembly NB DON’T Remove the Earth Connection from the Wrapper Phase 2 Topdeck Showing Wiring ConnectionsPage Page Assembly Guidelines Assembly Motor Assembly & DisassemblyPump Blockage Shaft & Bearing Removal Shaft & Bearing Assembly Page Wash Progress LEDs Appendix a Binary Decoding Chart 8 BitsImportant Note Size SettingFault Finding / Fault Codes Pump Hood Kit Part Number 479188P WM013 Pump Hood KIT January 2000 Phases 2 toWiring Connections WM51 Diagnostic Flow Chart Sept 1992- Phase 1 only Kit Lever Out of Balance & Bracket Phase 2 Part Number WM65 BIB Deflector April 1994- Phase 1 onlyWM70 Premature OUT of Balance February 1995 Phase 2 only WM81 Pump Shield 5KG Smartdrive September 1996 Phases 1 to WM80 Condensation KIT May 1996 Phase 2 & 3 onlyAppendix C Smarttool Appendix D Tools for Servicing Smartdrive IW Quick Reference Guide Specifications for IWModels Size Width Wash Load Capacity Compact Medium LargeWash 1 Detergent Activating Wash Front loader type wash Introduction to IWWater Temperature Sensing Pump Option Adjustment Mode for IWOther Options Status Display Diagnostic Mode for IWFault Status Recycle Size Setting Mode for IW