Fisher & Paykel 517735 service manual Phase 1 Pump Connection Fault, Primary Source Pump Action

Page 50

14.(00001110) Phase 1 - Pump Connection Fault

The Display Module has detected that the pump is not on when it should be.

Primary Source - Pump

Action

1.The pump is fitted with a thermal cut out device. Check if this device has been activated. If the device is activated wait until pump cools down before restarting. Check for any pump blockage and check condition of pump (pump seizure).

2.Check for open circuit pump windings. Check the resistance of the pump.

3.Check the pump harness or the connectors for an open circuit.

4.Replace Display Module.

15.(00001111) Phase 1 - Display Module Fault

The Display Module has read an incorrect voltage on the pump circuit.

Primary Source - Display Module

Action - Replace Display Module. NB. If Smartdrive is running at well below it's rated supply voltage and the pump has operated for more than 4 seconds at this voltage this fault will also appear.

17 – 20. (00010xxx) Phase 1 - Display / Motor Controller Out of Sequence 22 - 23. (000101xx) Phase 1 - Display / Motor Controller Out of Sequence

The Display Module and Motor Controller are running out of sequence.

Primary Source

Action

Turn off Smartdrive at the wall and back on again after 5 seconds. Re-start.

If fault persists disable auto restart feature and retest. A new fault code will appear. Carry out action of new fault details.

25.(00011001) Phase 5 IW – LCD Initialisation Error

The intuitive display has detected a problem with the LCD.

Primary Source – IW Display Module

Action - Replace IW Display Module

28 – 30. (000111xx) Phase 1 - Display / Motor Controller out of Sequence

Refer to fault code 17

- 45 -

Image 50
Contents Phase 1 to 5 Smart Drive Electronic Washing MachinePhase 5 IW Phase 3 GWPhase 4 GW Phase 5 IwecoWhat PHASE, Size & Model is Your SMARTDRIVE? MW, GWTable of Contents Recycle Introduction HOW to Service SmartdriveIf Smartdrive has no Power see Section Smartdrive Servicing Quick Reference Guide Specifications ALL Terminals and Internal Parts should be Treated AS LiveRemoving Transit Restraint InstallationInstallation Inlet HosesAccessories and Spare Parts Installation Environment Water Supply TemperaturesSafety Levelling SmartdriveSmartdrive Components Electronics Systems Phase Wiring Diagram Specifications MotorMotor Controller Module Water Level Measurement Pressure SensorDisplay Module Water Valves Installation Rotor Position SensorPump Motor Specifications PumpDiagram showing the Floating Bowl Inner and Outer BowlsDetection Of Inner Bowl Float Off Point Bowl Check Lid Switch and Out of Balance Switch Lid SwitchWater Temperature Sensing Smartdrive Information Favourite cycle GW only All PhasesCustomising Wash Cycles GW only Phase 3 to 5 only Water Saver GW only Phase 3 to 5 only Delay Start GW only Phase 2 to 5 onlyAuto Water Level GW only Phase 3 to 5 only Fabric Softener Dispenser All Phases Amount of Water Used in the Water Saver RinseWash Performance Information All Phases CreasingIf Smartdrive Powers Off mid cycle Smartdrive ProblemsIf Smartdrive Appears To Have No Power Noisy FloodingLeaking Continuous Spinning or Slow Spinning Poor Wash PerformanceEarth Leakage SiphoningRadio Frequency Interference RFI It Appears Smartdrive is doing nothingOption Adjustment Mode Wash Water Temperature All PhasesRinse Options All Phases Method of Setting the Wash TemperatureEnd of Cycle Warning Beeps GW Only All Phases PhaseAuto Water Fill Level Adjustment GW only Phase Out Of Balance Recovery Adjustment GW and MW only PhaseDiagnostic Mode What WAS the Last FAULT?Test LID, OUT of BALANCE, & Size Switches To Test Pump & Water ValvesLOW Water Level LED OFF = Restart OFF RestartRecycle Medium Water Level LED on = RE-CYCLE onPage Size Setting Mode Phase 4 and 5 only Insufficient Cold Water Cold Water LED flashing User WarningsInsufficient Hot Water Hot Water LED flashing No Water Both Hot and Cold Water LEDs flashing Overloaded Product High Water LED flashingRestart and Recycle Wash Progress LEDs flashing Phase 4Phase 1 to Demonstration Mode All LEDs flashing in patterns GWC09 GWM09 GWL09 Fault CodesGWC08 GWM08 GWL08 THC08 THM08 THL08 IWM09 IWL09Phase 1 Communications Fault Smartdrive Phases 1 to 5 Fault DescriptionsPhase 1 to 5 Motor Controller Fault Primary Source Motor ControllerPrimary Source Display Module Action Phase 1 to 5 Display Module FaultPhase 1 to 5 Size Error Primary Source Display ModuleAction Phase Phase 4 toPhase 1 to 5 Thermistor Error Phase 2 toPhase 1 Pump Fault Phase 1 to 5 Pressure Sensor FaultPhase 1 to 5 Flood Protection Error Primary Source Pressure Tube28 30 xx Phase 1 Display / Motor Controller out of Sequence Phase 1 Pump Connection FaultPhase 5 IW LCD Initialisation Error Primary Source Pump ActionPhase 1 MC Reset Error Phase 1 Pump Circuit ErrorPhase 1 Brake Resistor Fault Primary Source Pump System Phase 1 to 5 Water Leak FaultPhase 1 to 5 Pump Block Error Secondary Source Mechanical ActionPrimary Source Mechanical Phase 1 to 5 Tap or Pressure Sensor Tube FaultPhase 1 to 5 Bowl Dis-Engaged Fault Primary Source SudsPhase 1 to 5 OOB Switch Fault Phase 1 to 5 Temperature Sensor FaultPhase 1 Rotor Fault Primary Source Primary Source Mechanical ActionPrimary Source Pump System Action Phase 2 to 5 Water in Bowl During SpinPhase 5 Display Fault Secondary Source Motor ControllerPrimary Source Wiring Phase 2 to 3 Bowl Dis-engaged FaultPhase 2 to 5 Hot and Cold Valve Fault Phase 2 to 5 Cold Valve FaultPhase 5 ECO Recirculation Fault See fault code Phase 2 to 5 Hot Valve FaultPhase 5 ECO Recirculation Fault Secondary Source Diverter ValveSecondary Source Motor Phase 2 to 5 Rotor Position Sensor FaultPhase 2 to 5 Motor / Motor Control Step Fail Phase 4 to 5 Bowl Check Fault Phase 4 to 5 Motor Controller FaultPhase 4 Motor Controller Fault Primary Source- PumpPhase 2 to 3 Display / Motor Controller Comms. Error Phase 5 Machine Setup ErrorPhase 1 to 5 Single Rotor Position Sensor Error Primary Source Wiring ActionPhase 1 to 4 Repetitive Current Trip Phase 1 to 5 Repetitive Rotor Position Sensor ErrorPhase 1 to 4 Single Current Trip Phase 4 Single Current Trip & Rotor Position Sensor ErrorPhase 1 to 5 Motor Stall Phase 1 to 5 Bowl Engaged During Agitate Phase 4 to 5 Brake Function Time-out Fault Phase 5 Topdeck Showing Wiring Connections Mechanical Service SectionComplete Disassembly Phase 2 Topdeck Showing Wiring Connections NB DON’T Remove the Earth Connection from the WrapperPage Page Assembly Guidelines Motor Assembly & Disassembly AssemblyPump Blockage Shaft & Bearing Removal Shaft & Bearing Assembly Page Appendix a Binary Decoding Chart 8 Bits Wash Progress LEDsImportant Note Size SettingFault Finding / Fault Codes Pump Hood Kit Part Number 479188P WM013 Pump Hood KIT January 2000 Phases 2 toWiring Connections WM51 Diagnostic Flow Chart Sept 1992- Phase 1 only Kit Lever Out of Balance & Bracket Phase 2 Part Number WM65 BIB Deflector April 1994- Phase 1 onlyWM70 Premature OUT of Balance February 1995 Phase 2 only WM80 Condensation KIT May 1996 Phase 2 & 3 only WM81 Pump Shield 5KG Smartdrive September 1996 Phases 1 toAppendix C Smarttool Appendix D Tools for Servicing Smartdrive Models Size Width Wash Load Capacity Specifications for IWIW Quick Reference Guide Compact Medium LargeIntroduction to IW Wash 1 Detergent Activating Wash Front loader type washWater Temperature Sensing Option Adjustment Mode for IW PumpOther Options Diagnostic Mode for IW Status DisplayFault Status Size Setting Mode for IW Recycle