14.(00001110) Phase 1 - Pump Connection Fault
The Display Module has detected that the pump is not on when it should be.
Primary Source - Pump
Action
1.The pump is fitted with a thermal cut out device. Check if this device has been activated. If the device is activated wait until pump cools down before restarting. Check for any pump blockage and check condition of pump (pump seizure).
2.Check for open circuit pump windings. Check the resistance of the pump.
3.Check the pump harness or the connectors for an open circuit.
4.Replace Display Module.
15.(00001111) Phase 1 - Display Module Fault
The Display Module has read an incorrect voltage on the pump circuit.
Primary Source - Display Module
Action - Replace Display Module. NB. If Smartdrive is running at well below it's rated supply voltage and the pump has operated for more than 4 seconds at this voltage this fault will also appear.
17 – 20. (00010xxx) Phase 1 - Display / Motor Controller Out of Sequence 22 - 23. (000101xx) Phase 1 - Display / Motor Controller Out of Sequence
The Display Module and Motor Controller are running out of sequence.
Primary Source
Action
Turn off Smartdrive at the wall and back on again after 5 seconds.
If fault persists disable auto restart feature and retest. A new fault code will appear. Carry out action of new fault details.
25.(00011001) Phase 5 IW – LCD Initialisation Error
The intuitive display has detected a problem with the LCD.
Primary Source – IW Display Module
Action - Replace IW Display Module
28 – 30. (000111xx) Phase 1 - Display / Motor Controller out of Sequence
Refer to fault code 17