Fisher & Paykel 517735 Phase 2 to 5 Rotor Position Sensor Fault, Secondary Source Motor

Page 58

53.(00110011) Phase 2 to 5 - Rotor Position Sensor Fault

The Motor Controller has attempted a motor step test and has found that the motor has not stepped to the correct position. It has detected that the motor is connected and that the Motor Controller drive is operational. The Rotor Position Sensor signal sensing system is at fault.

Primary Source - Wiring

Action - Check the Rotor Position Sensor harness for continuity and that the connectors are correctly applied to the Rotor Position Sensor and to the Motor Controller.

Secondary Source - Rotor Position Sensor

Action - Check Rotor Position Sensor with RPS Tester or Replace Rotor Position Sensor.

Tertiary Source - Motor Controller

Action - The Motor Controller motor sensing circuitry may be faulty. Replace Motor Controller.

54.(00110110) Phase 2 to 5 - Motor / Motor Control Step Fail

The Motor Controller has attempted a motor step test and has found that the motor has not stepped to the correct position. The Motor Controller has detected that there is no motor current. This indicates that either the motor is not connected or the Motor Controller motor drive is faulty.

Primary Source - Wiring

Action - Check the continuity of the motor harness and that the connectors are correctly applied to the stator and to the Motor Controller.

Secondary Source - Motor

Action - Check resistance of motor phases. Check the brass bridge terminal on the stator is not open circuit or burnt. Otherwise replace stator.

Tertiary Source - Motor Controller Action - Replace Motor Controller.

55.(00110111) Phase 3 to 5 - System Step Fail

Primary Source - Rotor Position Sensor

Action

1.Check Motor & Rotor Position Sensor wiring

2.Check Rotor Position Sensor with RPS tester

- 53 -

Image 58
Contents Phase 1 to 5 Smart Drive Electronic Washing MachinePhase 5 IW Phase 3 GWPhase 4 GW Phase 5 IwecoWhat PHASE, Size & Model is Your SMARTDRIVE? MW, GWTable of Contents Recycle If Smartdrive has no Power see Section HOW to Service SmartdriveIntroduction Smartdrive Servicing Quick Reference Guide Specifications ALL Terminals and Internal Parts should be Treated AS LiveRemoving Transit Restraint InstallationInstallation Inlet HosesAccessories and Spare Parts Installation Environment Water Supply TemperaturesSafety Levelling SmartdriveSmartdrive Components Electronics Systems Phase Wiring Diagram Specifications MotorMotor Controller Module Water Level Measurement Pressure SensorDisplay Module Water Valves Installation Rotor Position SensorPump Motor Specifications PumpDiagram showing the Floating Bowl Inner and Outer BowlsDetection Of Inner Bowl Float Off Point Bowl Check Lid Switch and Out of Balance Switch Lid SwitchWater Temperature Sensing Customising Wash Cycles GW only Phase 3 to 5 only Favourite cycle GW only All PhasesSmartdrive Information Auto Water Level GW only Phase 3 to 5 only Delay Start GW only Phase 2 to 5 onlyWater Saver GW only Phase 3 to 5 only Fabric Softener Dispenser All Phases Amount of Water Used in the Water Saver RinseWash Performance Information All Phases CreasingIf Smartdrive Appears To Have No Power Smartdrive ProblemsIf Smartdrive Powers Off mid cycle Leaking FloodingNoisy Continuous Spinning or Slow Spinning Poor Wash PerformanceEarth Leakage SiphoningRadio Frequency Interference RFI It Appears Smartdrive is doing nothingOption Adjustment Mode Wash Water Temperature All PhasesRinse Options All Phases Method of Setting the Wash TemperatureEnd of Cycle Warning Beeps GW Only All Phases PhaseAuto Water Fill Level Adjustment GW only Phase Out Of Balance Recovery Adjustment GW and MW only PhaseDiagnostic Mode What WAS the Last FAULT?Test LID, OUT of BALANCE, & Size Switches To Test Pump & Water ValvesLOW Water Level LED OFF = Restart OFF RestartRecycle Medium Water Level LED on = RE-CYCLE onPage Size Setting Mode Phase 4 and 5 only Insufficient Hot Water Hot Water LED flashing User WarningsInsufficient Cold Water Cold Water LED flashing No Water Both Hot and Cold Water LEDs flashing Overloaded Product High Water LED flashingPhase 1 to Phase 4Restart and Recycle Wash Progress LEDs flashing Demonstration Mode All LEDs flashing in patterns GWC09 GWM09 GWL09 Fault CodesGWC08 GWM08 GWL08 THC08 THM08 THL08 IWM09 IWL09Phase 1 Communications Fault Smartdrive Phases 1 to 5 Fault DescriptionsPhase 1 to 5 Motor Controller Fault Primary Source Motor ControllerPrimary Source Display Module Action Phase 1 to 5 Display Module FaultPhase 1 to 5 Size Error Primary Source Display ModuleAction Phase Phase 4 toPhase 1 to 5 Thermistor Error Phase 2 toPhase 1 Pump Fault Phase 1 to 5 Pressure Sensor FaultPhase 1 to 5 Flood Protection Error Primary Source Pressure Tube28 30 xx Phase 1 Display / Motor Controller out of Sequence Phase 1 Pump Connection FaultPhase 5 IW LCD Initialisation Error Primary Source Pump ActionPhase 1 Brake Resistor Fault Phase 1 Pump Circuit ErrorPhase 1 MC Reset Error Primary Source Pump System Phase 1 to 5 Water Leak FaultPhase 1 to 5 Pump Block Error Secondary Source Mechanical ActionPrimary Source Mechanical Phase 1 to 5 Tap or Pressure Sensor Tube FaultPhase 1 to 5 Bowl Dis-Engaged Fault Primary Source SudsPhase 1 to 5 OOB Switch Fault Phase 1 to 5 Temperature Sensor FaultPhase 1 Rotor Fault Primary Source Primary Source Mechanical ActionPrimary Source Pump System Action Phase 2 to 5 Water in Bowl During SpinPhase 5 Display Fault Secondary Source Motor ControllerPrimary Source Wiring Phase 2 to 3 Bowl Dis-engaged FaultPhase 2 to 5 Hot and Cold Valve Fault Phase 2 to 5 Cold Valve FaultPhase 5 ECO Recirculation Fault See fault code Phase 2 to 5 Hot Valve FaultPhase 5 ECO Recirculation Fault Secondary Source Diverter ValvePhase 2 to 5 Motor / Motor Control Step Fail Phase 2 to 5 Rotor Position Sensor FaultSecondary Source Motor Phase 4 to 5 Bowl Check Fault Phase 4 to 5 Motor Controller FaultPhase 4 Motor Controller Fault Primary Source- PumpPhase 2 to 3 Display / Motor Controller Comms. Error Phase 5 Machine Setup ErrorPhase 1 to 5 Single Rotor Position Sensor Error Primary Source Wiring ActionPhase 1 to 4 Repetitive Current Trip Phase 1 to 5 Repetitive Rotor Position Sensor ErrorPhase 1 to 4 Single Current Trip Phase 4 Single Current Trip & Rotor Position Sensor ErrorPhase 1 to 5 Motor Stall Phase 1 to 5 Bowl Engaged During Agitate Phase 4 to 5 Brake Function Time-out Fault Complete Disassembly Mechanical Service SectionPhase 5 Topdeck Showing Wiring Connections Phase 2 Topdeck Showing Wiring Connections NB DON’T Remove the Earth Connection from the WrapperPage Page Assembly Guidelines Motor Assembly & Disassembly AssemblyPump Blockage Shaft & Bearing Removal Shaft & Bearing Assembly Page Appendix a Binary Decoding Chart 8 Bits Wash Progress LEDsFault Finding / Fault Codes Size SettingImportant Note Wiring Connections WM013 Pump Hood KIT January 2000 Phases 2 toPump Hood Kit Part Number 479188P WM51 Diagnostic Flow Chart Sept 1992- Phase 1 only WM70 Premature OUT of Balance February 1995 Phase 2 only WM65 BIB Deflector April 1994- Phase 1 onlyKit Lever Out of Balance & Bracket Phase 2 Part Number WM80 Condensation KIT May 1996 Phase 2 & 3 only WM81 Pump Shield 5KG Smartdrive September 1996 Phases 1 toAppendix C Smarttool Appendix D Tools for Servicing Smartdrive Models Size Width Wash Load Capacity Specifications for IWIW Quick Reference Guide Compact Medium LargeIntroduction to IW Wash 1 Detergent Activating Wash Front loader type washWater Temperature Sensing Option Adjustment Mode for IW PumpOther Options Diagnostic Mode for IW Status DisplayFault Status Size Setting Mode for IW Recycle