Fisher & Paykel 517735 Phase 2 to 3 Bowl Dis-engaged Fault, Phase 2 to 5 Hot and Cold Valve Fault

Page 56

47.(00101111) Phase 2 to 3 - Bowl Dis-engaged Fault

While carrying out a bowl check, the Motor Controller has found that the bowl is not engaged even though the pressure sensor indicates that the bowl is empty. The Motor Controller continues to check for 2 minutes. During this time the module has not been able to determine a valid bowl status and so displays this fault. This fault differs from fault 40 in that a valid bowl status could not be determined. The first two areas to check are the clutch and the pressure tube. If these two appear correct, then the fault could be with the pressure sensor in the Motor Controller.

Primary Source - Mechanical

Action

1.Check that there are no clothes or other foreign objects preventing the clutch from re- engaging.

2.Next check that the pressure tube has not come off and that it is not kinked.

Secondary Source - Motor Controller.

Action - Replace Motor Controller, if the above checks out without fault.

48.(00110000) Phase 2 to 5 - Hot and Cold Valve Fault

The Motor Controller has measured voltages from the valve diagnostic circuit that indicate both the hot and cold valve are faulty. The most likely cause is that the valve harnesses have not been connected correctly.

Primary Source - Wiring

Action - Check valve harnesses are correctly fastened to valves.

Secondary Source - Water Valves

Action - Check valve coils are not faulty ( open circuit ).

Tertiary Source - Motor Controller

Action - The valve drivers or valve diagnostic circuit may be at fault. If the primary and secondary checks pass inspection then replace the Motor Controller.

49.(00110001) Phase 2 to 5 - Cold Valve Fault

The Motor Controller has measured a voltage from the valve diagnostic circuit that indicates the cold valve is faulty. The most likely cause is that the valve harness has not been connected correctly. See fault 48. for service procedure.

- 51 -

Image 56
Contents Phase 1 to 5 Smart Drive Electronic Washing MachinePhase 3 GW Phase 4 GWPhase 5 IW Phase 5 IwecoWhat PHASE, Size & Model is Your SMARTDRIVE? MW, GWTable of Contents Recycle Introduction HOW to Service SmartdriveIf Smartdrive has no Power see Section Smartdrive Servicing Quick Reference Guide Specifications ALL Terminals and Internal Parts should be Treated AS LiveInstallation InstallationRemoving Transit Restraint Inlet HosesInstallation Environment Water Supply Temperatures SafetyAccessories and Spare Parts Levelling SmartdriveSmartdrive Components Electronics Systems Phase Wiring Diagram Specifications MotorMotor Controller Module Water Level Measurement Pressure SensorDisplay Module Water Valves Installation Rotor Position SensorPump Motor Specifications PumpDiagram showing the Floating Bowl Inner and Outer BowlsDetection Of Inner Bowl Float Off Point Bowl Check Lid Switch and Out of Balance Switch Lid SwitchWater Temperature Sensing Smartdrive Information Favourite cycle GW only All PhasesCustomising Wash Cycles GW only Phase 3 to 5 only Water Saver GW only Phase 3 to 5 only Delay Start GW only Phase 2 to 5 onlyAuto Water Level GW only Phase 3 to 5 only Fabric Softener Dispenser All Phases Amount of Water Used in the Water Saver RinseWash Performance Information All Phases CreasingIf Smartdrive Powers Off mid cycle Smartdrive ProblemsIf Smartdrive Appears To Have No Power Noisy FloodingLeaking Continuous Spinning or Slow Spinning Poor Wash PerformanceSiphoning Radio Frequency Interference RFIEarth Leakage It Appears Smartdrive is doing nothingOption Adjustment Mode Wash Water Temperature All PhasesRinse Options All Phases Method of Setting the Wash TemperatureEnd of Cycle Warning Beeps GW Only All Phases PhaseAuto Water Fill Level Adjustment GW only Phase Out Of Balance Recovery Adjustment GW and MW only PhaseDiagnostic Mode What WAS the Last FAULT?Test LID, OUT of BALANCE, & Size Switches To Test Pump & Water ValvesRestart RecycleLOW Water Level LED OFF = Restart OFF Medium Water Level LED on = RE-CYCLE onPage Size Setting Mode Phase 4 and 5 only Insufficient Cold Water Cold Water LED flashing User WarningsInsufficient Hot Water Hot Water LED flashing No Water Both Hot and Cold Water LEDs flashing Overloaded Product High Water LED flashingRestart and Recycle Wash Progress LEDs flashing Phase 4Phase 1 to Demonstration Mode All LEDs flashing in patterns Fault Codes GWC08 GWM08 GWL08 THC08 THM08 THL08GWC09 GWM09 GWL09 IWM09 IWL09Smartdrive Phases 1 to 5 Fault Descriptions Phase 1 to 5 Motor Controller FaultPhase 1 Communications Fault Primary Source Motor ControllerPhase 1 to 5 Display Module Fault Phase 1 to 5 Size ErrorPrimary Source Display Module Action Primary Source Display ModulePhase 4 to Phase 1 to 5 Thermistor ErrorAction Phase Phase 2 toPhase 1 to 5 Pressure Sensor Fault Phase 1 to 5 Flood Protection ErrorPhase 1 Pump Fault Primary Source Pressure TubePhase 1 Pump Connection Fault Phase 5 IW LCD Initialisation Error28 30 xx Phase 1 Display / Motor Controller out of Sequence Primary Source Pump ActionPhase 1 MC Reset Error Phase 1 Pump Circuit ErrorPhase 1 Brake Resistor Fault Phase 1 to 5 Water Leak Fault Phase 1 to 5 Pump Block ErrorPrimary Source Pump System Secondary Source Mechanical ActionPhase 1 to 5 Tap or Pressure Sensor Tube Fault Phase 1 to 5 Bowl Dis-Engaged FaultPrimary Source Mechanical Primary Source SudsPhase 1 to 5 Temperature Sensor Fault Phase 1 Rotor Fault Primary SourcePhase 1 to 5 OOB Switch Fault Primary Source Mechanical ActionPhase 2 to 5 Water in Bowl During Spin Phase 5 Display FaultPrimary Source Pump System Action Secondary Source Motor ControllerPhase 2 to 3 Bowl Dis-engaged Fault Phase 2 to 5 Hot and Cold Valve FaultPrimary Source Wiring Phase 2 to 5 Cold Valve FaultPhase 2 to 5 Hot Valve Fault Phase 5 ECO Recirculation FaultPhase 5 ECO Recirculation Fault See fault code Secondary Source Diverter ValveSecondary Source Motor Phase 2 to 5 Rotor Position Sensor FaultPhase 2 to 5 Motor / Motor Control Step Fail Phase 4 to 5 Bowl Check Fault Phase 4 to 5 Motor Controller FaultPhase 4 Motor Controller Fault Primary Source- PumpPhase 2 to 3 Display / Motor Controller Comms. Error Phase 5 Machine Setup ErrorPhase 1 to 5 Single Rotor Position Sensor Error Primary Source Wiring ActionPhase 1 to 5 Repetitive Rotor Position Sensor Error Phase 1 to 4 Single Current TripPhase 1 to 4 Repetitive Current Trip Phase 4 Single Current Trip & Rotor Position Sensor ErrorPhase 1 to 5 Motor Stall Phase 1 to 5 Bowl Engaged During Agitate Phase 4 to 5 Brake Function Time-out Fault Phase 5 Topdeck Showing Wiring Connections Mechanical Service SectionComplete Disassembly Phase 2 Topdeck Showing Wiring Connections NB DON’T Remove the Earth Connection from the WrapperPage Page Assembly Guidelines Motor Assembly & Disassembly AssemblyPump Blockage Shaft & Bearing Removal Shaft & Bearing Assembly Page Appendix a Binary Decoding Chart 8 Bits Wash Progress LEDsImportant Note Size SettingFault Finding / Fault Codes Pump Hood Kit Part Number 479188P WM013 Pump Hood KIT January 2000 Phases 2 toWiring Connections WM51 Diagnostic Flow Chart Sept 1992- Phase 1 only Kit Lever Out of Balance & Bracket Phase 2 Part Number WM65 BIB Deflector April 1994- Phase 1 onlyWM70 Premature OUT of Balance February 1995 Phase 2 only WM80 Condensation KIT May 1996 Phase 2 & 3 only WM81 Pump Shield 5KG Smartdrive September 1996 Phases 1 toAppendix C Smarttool Appendix D Tools for Servicing Smartdrive Specifications for IW IW Quick Reference GuideModels Size Width Wash Load Capacity Compact Medium LargeIntroduction to IW Wash 1 Detergent Activating Wash Front loader type washWater Temperature Sensing Option Adjustment Mode for IW PumpOther Options Diagnostic Mode for IW Status DisplayFault Status Size Setting Mode for IW Recycle