Fisher & Paykel 517735 service manual Fault Status

Page 91

FAULT STATUS

The Fault Status screen will display the fault code for the current or last fault that has occurred in Smartdrive. It will also display how many cycles ago the fault occurred and at what part of the cycle. The fault code can be checked in Section 11 to identify the repairs that may be necessary.

Fault Status

Fault code: 130

5 cycles ago

at progress SPIN

DRAIN PUMP TEST

When in diagnostic mode, the FABRIC CARE button turns the drain pump on or off. This can be helpful if the bowl is still full of water. The pump is run at 50Hz for this test. When in the 50Hz mode, the pump will not turn on and off every 10 seconds. When running this test the state of the diverter valve should be known. This is the best method for checking the recirculation system. Always check that there is no water pumped to drain when the product is recirculating and vice versa.

WATER VALVE TEST

When in diagnostic mode, pressing the HOW DIRTY down button will turn the Cold Water Valve on. Pressing the HOW DIRTY up button will turn the Hot Water Valve on. The buttons must be held on to keep the valves on.

RESTART

When in diagnostic mode, pressing the OPTION button will bring up the Control Option screen.

Control Options

restart recycle

hot bowl clear

Smartdrive defaults to RESTART ON. This is indicated on the screen by the word RESTART highlighted. To turn RESTART OFF, push the button alongside the word. This will remove the highlight from the word RESTART. When Smartdrive is being serviced it is more convenient to turn RESTART OFF. This will allow any fault in the system to show up immediately.

With RESTART ON:

If a fault occurs in Smartdrive, the diagnostic system will detect it. However, instead of displaying a fault code immediately, Smartdrive will retry several times.

If the fault was only of temporary nature, Smartdrive will finish the cycle.

If there is a continuous fault Smartdrive will retry a number of times. This process could take up to 8 minutes depending on the type of fault. After this, if Smartdrive still cannot restart, the fault code is displayed and will beep continuously.

The status of RESTART is indicated during normal use of Smartdrive as follows: - If none of the 5 green “HOW DIRTY” LED’s are on, RESTART is on.

If the 5 green “HOW DIRTY” LED’s are flashing, RESTART is off.

NB: RESTART is designed as a service aid only and should be left ON in the customer’s home. To return to normal operation, and to reset RESTART to the default setting, switch Smartdrive off at the wall. If this does not reset the state then RESTART and RECYCLE must be reset in EEPROM. To set these states hold down the button adjacent to the LCD for 2 seconds, Smartdrive will beep once.

- 86 -

Image 91
Contents Smart Drive Electronic Washing Machine Phase 1 to 5Phase 5 Iweco Phase 3 GWPhase 4 GW Phase 5 IWMW, GW What PHASE, Size & Model is Your SMARTDRIVE?Table of Contents Recycle If Smartdrive has no Power see Section HOW to Service SmartdriveIntroduction Smartdrive Servicing Quick Reference Guide ALL Terminals and Internal Parts should be Treated AS Live SpecificationsInlet Hoses InstallationInstallation Removing Transit RestraintLevelling Smartdrive Installation Environment Water Supply TemperaturesSafety Accessories and Spare PartsSmartdrive Components Electronics Systems Phase Wiring Diagram Motor SpecificationsWater Level Measurement Pressure Sensor Motor Controller ModuleDisplay Module Water Valves Rotor Position Sensor InstallationPump Pump Motor SpecificationsInner and Outer Bowls Diagram showing the Floating BowlDetection Of Inner Bowl Float Off Point Bowl Check Lid Switch Lid Switch and Out of Balance SwitchWater Temperature Sensing Customising Wash Cycles GW only Phase 3 to 5 only Favourite cycle GW only All PhasesSmartdrive Information Auto Water Level GW only Phase 3 to 5 only Delay Start GW only Phase 2 to 5 onlyWater Saver GW only Phase 3 to 5 only Amount of Water Used in the Water Saver Rinse Fabric Softener Dispenser All PhasesCreasing Wash Performance Information All PhasesIf Smartdrive Appears To Have No Power Smartdrive ProblemsIf Smartdrive Powers Off mid cycle Leaking FloodingNoisy Poor Wash Performance Continuous Spinning or Slow SpinningIt Appears Smartdrive is doing nothing SiphoningRadio Frequency Interference RFI Earth LeakageWash Water Temperature All Phases Option Adjustment ModeMethod of Setting the Wash Temperature Rinse Options All PhasesPhase End of Cycle Warning Beeps GW Only All PhasesOut Of Balance Recovery Adjustment GW and MW only Phase Auto Water Fill Level Adjustment GW only PhaseWhat WAS the Last FAULT? Diagnostic ModeTo Test Pump & Water Valves Test LID, OUT of BALANCE, & Size SwitchesMedium Water Level LED on = RE-CYCLE on RestartRecycle LOW Water Level LED OFF = Restart OFFPage Size Setting Mode Phase 4 and 5 only Insufficient Hot Water Hot Water LED flashing User WarningsInsufficient Cold Water Cold Water LED flashing Overloaded Product High Water LED flashing No Water Both Hot and Cold Water LEDs flashingPhase 1 to Phase 4Restart and Recycle Wash Progress LEDs flashing Demonstration Mode All LEDs flashing in patterns IWM09 IWL09 Fault CodesGWC08 GWM08 GWL08 THC08 THM08 THL08 GWC09 GWM09 GWL09Primary Source Motor Controller Smartdrive Phases 1 to 5 Fault DescriptionsPhase 1 to 5 Motor Controller Fault Phase 1 Communications FaultPrimary Source Display Module Phase 1 to 5 Display Module FaultPhase 1 to 5 Size Error Primary Source Display Module ActionPhase 2 to Phase 4 toPhase 1 to 5 Thermistor Error Action PhasePrimary Source Pressure Tube Phase 1 to 5 Pressure Sensor FaultPhase 1 to 5 Flood Protection Error Phase 1 Pump FaultPrimary Source Pump Action Phase 1 Pump Connection FaultPhase 5 IW LCD Initialisation Error 28 30 xx Phase 1 Display / Motor Controller out of SequencePhase 1 Brake Resistor Fault Phase 1 Pump Circuit ErrorPhase 1 MC Reset Error Secondary Source Mechanical Action Phase 1 to 5 Water Leak FaultPhase 1 to 5 Pump Block Error Primary Source Pump SystemPrimary Source Suds Phase 1 to 5 Tap or Pressure Sensor Tube FaultPhase 1 to 5 Bowl Dis-Engaged Fault Primary Source MechanicalPrimary Source Mechanical Action Phase 1 to 5 Temperature Sensor FaultPhase 1 Rotor Fault Primary Source Phase 1 to 5 OOB Switch FaultSecondary Source Motor Controller Phase 2 to 5 Water in Bowl During SpinPhase 5 Display Fault Primary Source Pump System ActionPhase 2 to 5 Cold Valve Fault Phase 2 to 3 Bowl Dis-engaged FaultPhase 2 to 5 Hot and Cold Valve Fault Primary Source WiringSecondary Source Diverter Valve Phase 2 to 5 Hot Valve FaultPhase 5 ECO Recirculation Fault Phase 5 ECO Recirculation Fault See fault codePhase 2 to 5 Motor / Motor Control Step Fail Phase 2 to 5 Rotor Position Sensor FaultSecondary Source Motor Phase 4 to 5 Motor Controller Fault Phase 4 to 5 Bowl Check FaultPrimary Source- Pump Phase 4 Motor Controller FaultPhase 5 Machine Setup Error Phase 2 to 3 Display / Motor Controller Comms. ErrorPrimary Source Wiring Action Phase 1 to 5 Single Rotor Position Sensor ErrorPhase 4 Single Current Trip & Rotor Position Sensor Error Phase 1 to 5 Repetitive Rotor Position Sensor ErrorPhase 1 to 4 Single Current Trip Phase 1 to 4 Repetitive Current TripPhase 1 to 5 Motor Stall Phase 1 to 5 Bowl Engaged During Agitate Phase 4 to 5 Brake Function Time-out Fault Complete Disassembly Mechanical Service SectionPhase 5 Topdeck Showing Wiring Connections NB DON’T Remove the Earth Connection from the Wrapper Phase 2 Topdeck Showing Wiring ConnectionsPage Page Assembly Guidelines Assembly Motor Assembly & DisassemblyPump Blockage Shaft & Bearing Removal Shaft & Bearing Assembly Page Wash Progress LEDs Appendix a Binary Decoding Chart 8 BitsFault Finding / Fault Codes Size SettingImportant Note Wiring Connections WM013 Pump Hood KIT January 2000 Phases 2 toPump Hood Kit Part Number 479188P WM51 Diagnostic Flow Chart Sept 1992- Phase 1 only WM70 Premature OUT of Balance February 1995 Phase 2 only WM65 BIB Deflector April 1994- Phase 1 onlyKit Lever Out of Balance & Bracket Phase 2 Part Number WM81 Pump Shield 5KG Smartdrive September 1996 Phases 1 to WM80 Condensation KIT May 1996 Phase 2 & 3 onlyAppendix C Smarttool Appendix D Tools for Servicing Smartdrive Compact Medium Large Specifications for IWIW Quick Reference Guide Models Size Width Wash Load CapacityWash 1 Detergent Activating Wash Front loader type wash Introduction to IWWater Temperature Sensing Pump Option Adjustment Mode for IWOther Options Status Display Diagnostic Mode for IWFault Status Recycle Size Setting Mode for IW