56.(00111000) Phase 4 to 5 - Bowl Check Fault
While carrying out a bowl check Smartdrive has not been able to determine a valid bowl status and so the Display flags this fault. This fault differs from fault 40 in that a valid bowl status could not be determined. The first two areas to check are the clutch and the pressure tube.
Primary Source - Mechanical
Action
1.Check that there are no clothes or other foreign objects preventing the clutch from re- engaging.
2.Check that the pressure tube has not come off and that it is not kinked.
Secondary Source - Motor Controller (Phase 4). Rotor Position Sensor (Phase 5) Action - Replace Motor Controller(Phase 4). Rotor Position Sensor (Phase 5).
57.(00111001) Phase 4 to 5 – Motor Controller Fault
The Display module has requested the Motor Controller to perform an EEPROM write. Prior to writing the Motor Controller has tested the 15 Volt supply and found that it is below a safe level for writing EEPROM and has reported this to the display. This may be due to mains transients at the time of write or due to a faulty Motor Controller.
Primary Source - Motor Controller Action - Replace Motor Controller
58.(00111010) Phase 4 to 5 – Pressure Transducer Fault The Pressure Transducer is outside normal limits.
Primary Source - Motor Controller Action - Replace Motor Controller
59.(00111011) Phase 4 to 5 - Display Module Fault
The Display module checked its physical ID on the display PCB and found it was out of range.
Primary Source - Display module Action - Replace Display module
60.(00111100) Phase 4 to 5 - Motor Controller Fault
On power up the Motor Controller has tested its ROM against a known reference and found differences.
Primary Source - Motor Controller Action - Replace Motor Controller