Troubleshooting Procedures
Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.
! CAUTION
All safety information must be followed as provided in the Service Manual.
!WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing.
Codes displayed but not listed here should be ignored.
DIAGNOSTIC CODE CHART
| Service | |
Service Code Description | Code | |
Model ID Unknown, Default model of 31 used | 31 | |
Rotary Switch 3 left of encoder failed at startup | 28 | |
Rotary Switch 2 left of encoder failed at startup | 26 | |
Rotary Switch 1 left of encoder failed at startup | 25 | |
Incorrect rotary switch position seen | 24 | |
Fill time less than 2 seconds | 22 | |
Fill time exceeded 18 minutes | 21 | |
Motor Thermal protector opened | 19 | |
Motor Thermal protector opened more than | 18 | |
5 times during a cycle | ||
| ||
Thermistor Possible Short | 17 | |
Thermistor Possible Open | 16 | |
Thermistor out of range | 15 | |
Power Failure detected | 1 | |
No code | 0 |
Fill | Soak | Wash | Rinse | Spin | Complete | Pause |
MODEL CODE CHART
Model Numbers | Fill Soak | Wash Rinse |
MAV546E |
|
|
MAV5920 AGW (INT) |
|
|
MAV508DE, MAV551E
MAV5758, MAV5858
MAV5920E
NAV8805
Pause
Complete
Spin
©2005 Maytag Services | 16026502 | 13 |