Disassembly Procedures
!WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing.
Console Disassembly
1.Disconnect power supply to unit.
2.Remove Cycle Selector Knob and Switch Knobs.
5.Disconnect all wiring harness connectors from the Circuit Board.
NOTE: Wear an Anti Static Wrist Strap and ground yourself before working with Electronic Control Boards. Always handle boards by the edge and don’t touch discreet components.
3.Remove three screws along the top of the Console and roll the Console forward.
6. Depress the PCB locking tab and remove Circuit Board.
4.Disconnect and remove Rocker Switches from Console.
7. Remove Switches by lifting locking tab and rotating Switch to align with hole molded in Console.
18 | 16026502 | ©2005 Maytag Services |