Disassembly Procedures
!WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing.
Motor Removal
1.Disconnect power supply to unit.
2.Lift Top Cover, see “Top Cover Removal” procedure.
3.Remove Front Panel, see “Front Panel Removal” procedure.
4.Remove Motor ground wire.
Flume/Thermistor Removal
1.Disconnect power supply to unit.
2.Remove Console, see “Console Disassembly” procedure.
3.Remove Flume screw from top of Top Cover.
4. Lift Top Cover, see “Top Cover Removal” procedure.
5. Remove Motor Shield.5. Remove two Flume retaining screws from bottom of Top Cover.
6. Remove Motor wire harness connector.
6. Remove hose clamp and Flume/Diverter Hose.
7. Remove three screws retaining Motor to Base.
22 | 16026502 | ©2005 Maytag Services |