Disassembly Procedures
!WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing.
Water Valve Removal
1.Disconnect power supply to unit.
2.Lift Top Cover, see “top Cover Removal” procedure.
3.Remove retaining screw on back panel.
Dispenser Removal
1.Disconnect power supply to unit.
2.Lift Top Cover, see “Top Cover Removal” procedure.
3.Relieve tension on Dispenser retaining tab.
4. Lift Water Valve to align with cutout in back cabinet.
Front Panel Removal
1. Disconnect power supply to unit.
2. Lift Top Cover, see “Top Cover Removal” procedure.
3. Remove two screws, 1 each side on Front Panel top edge.
©2005 Maytag Services | 16026502 | 21 |