SECTION II
SPECIFICATIONS and DIMENSIONS
A.SPECIFICATIONS (Gas and Steam Models)
Maximum Capacity (Dry Weight) |
| 410 lbs. |
|
| 186.4 kg | |||||
|
|
|
|
|
|
|
|
| ||
Minimum Capacity (Dry Weight) |
| 250 lbs. |
| 113.65 kg | ||||||
|
|
|
|
|
|
|
|
|
| |
Tumbler (Basket) Diameter |
|
|
| 174.6 cm | ||||||
|
|
|
|
|
|
|
|
|
| |
Tumbler (Basket) Depth |
|
|
| 168.6 cm | ||||||
|
|
|
|
|
|
|
|
| ||
Tumbler (Basket) Volume |
| 143 cu. ft. |
| 4.05 cu.m. | ||||||
|
|
|
|
|
|
|
|
|
| |
Drive Motor |
|
|
| 5.6 kw | ||||||
|
|
|
|
|
|
|
|
|
|
|
Blower Motor (Gas/Steam) |
|
| 25 HP |
|
| 18.7 kw | ||||
|
|
|
|
|
|
|
|
| ||
Door Opening |
| 40" Wide x 50" High |
| 101.6 cm x 127 cm | ||||||
|
|
|
|
|
|
|
|
|
|
|
Door Still Height - Level |
|
|
|
| 101 cm | |||||
|
|
|
|
|
|
|
|
|
| |
Compressed Air |
|
| 80 PSI |
| 5.51 bars | |||||
|
|
|
|
|
|
|
|
| ||
Compressed Air Connection | 3/8" F.P.T. |
|
| |||||||
|
|
|
|
|
|
|
|
|
| |
| Voltage Available |
|
| 3ø | 3, 4w 50/60 Hz | |||||
Gas* |
|
|
|
|
|
|
|
| ||
Airflow |
| 9,200 cfm |
| 261 cmm | ||||||
| Heat Input |
| 1,600,000 btu/hr |
| 403,200 kcal/hr | |||||
| Approx. Weight (Uncrated) | 7,500 lbs. |
| 3,409 kg | ||||||
|
|
|
|
|
|
|
|
|
|
|
| Inlet Pipe Size |
| 2" F.P.T. |
|
| 5.08 cm | ||||
|
|
|
|
|
|
|
|
|
| |
| Voltage Available |
|
| 3ø | 3, 4w 50/60 Hz | |||||
|
|
|
|
|
|
|
| |||
Steam* | Approx. Weight (Uncrated) | 8,000 lbs. |
| 3,636 kg | ||||||
|
|
|
|
|
|
|
|
|
| |
Airflow |
| 12,000 cfm |
| 340 cmm | ||||||
|
|
| ||||||||
|
|
|
|
|
|
|
|
| ||
| Steam Consumption | Normal Load |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| 1,815 lbs/hr |
| 825 kg/hr |
| 55 |
|
|
|
| |
|
|
|
|
|
|
|
| |||
| Operating Steam Pressure | Steam Supply |
| Steam Return | ||||||
|
|
|
|
|
|
|
|
|
|
|
| 125 PSI max |
| 8.79 kg/sq cm | 2" |
| 5.08 cm |
|
| 3.18 cm | |
|
|
|
|
|
|
|
|
|
| |
Shaded areas are stated in metric equivalents |
|
|
|
|
|
|
|
*Dryers must be provided with a clean, dry, regulated 80 PSI +/- 10 psi (5.512 bars +/- 0.68 bars) air supply (equivalent volume = 9 cfh [0.26 cmh]).
NOTE: ADC reserves the right to make changes in specifications at any time, without notice or obligation.