American Dryer Corp ML-410 manual Specifications and Dimensions

Page 21

SECTION II

SPECIFICATIONS and DIMENSIONS

A.SPECIFICATIONS (Gas and Steam Models)

Maximum Capacity (Dry Weight)

 

410 lbs.

 

 

186.4 kg

 

 

 

 

 

 

 

 

 

Minimum Capacity (Dry Weight)

 

250 lbs.

 

113.65 kg

 

 

 

 

 

 

 

 

 

 

Tumbler (Basket) Diameter

 

 

68-3/4"

 

174.6 cm

 

 

 

 

 

 

 

 

 

 

Tumbler (Basket) Depth

 

 

66-3/8"

 

168.6 cm

 

 

 

 

 

 

 

 

 

Tumbler (Basket) Volume

 

143 cu. ft.

 

4.05 cu.m.

 

 

 

 

 

 

 

 

 

 

Drive Motor

 

7-1/2 HP

 

 

5.6 kw

 

 

 

 

 

 

 

 

 

 

 

Blower Motor (Gas/Steam)

 

 

25 HP

 

 

18.7 kw

 

 

 

 

 

 

 

 

 

Door Opening

 

40" Wide x 50" High

 

101.6 cm x 127 cm

 

 

 

 

 

 

 

 

 

 

 

Door Still Height - Level

 

 

39-3/4"

 

 

101 cm

 

 

 

 

 

 

 

 

 

 

Compressed Air

 

 

80 PSI

 

5.51 bars

 

 

 

 

 

 

 

 

 

Compressed Air Connection

3/8" F.P.T.

 

 

----

 

 

 

 

 

 

 

 

 

 

 

Voltage Available

 

 

208-460v

3, 4w 50/60 Hz

Gas*

 

 

 

 

 

 

 

 

Airflow

 

9,200 cfm

 

261 cmm

 

Heat Input

 

1,600,000 btu/hr

 

403,200 kcal/hr

 

Approx. Weight (Uncrated)

7,500 lbs.

 

3,409 kg

 

 

 

 

 

 

 

 

 

 

 

 

Inlet Pipe Size

 

2" F.P.T.

 

 

5.08 cm

 

 

 

 

 

 

 

 

 

 

 

Voltage Available

 

 

208-460v

3, 4w 50/60 Hz

 

 

 

 

 

 

 

 

Steam*

Approx. Weight (Uncrated)

8,000 lbs.

 

3,636 kg

 

 

 

 

 

 

 

 

 

 

Airflow

 

12,000 cfm

 

340 cmm

 

 

 

 

 

 

 

 

 

 

 

 

 

Steam Consumption

Normal Load

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1,815 lbs/hr

 

825 kg/hr

 

55

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating Steam Pressure

Steam Supply

 

Steam Return

 

 

 

 

 

 

 

 

 

 

 

 

125 PSI max

 

8.79 kg/sq cm

2"

 

5.08 cm

 

1-1/4"

 

3.18 cm

 

 

 

 

 

 

 

 

 

 

Shaded areas are stated in metric equivalents

 

 

 

 

 

 

 

*Dryers must be provided with a clean, dry, regulated 80 PSI +/- 10 psi (5.512 bars +/- 0.68 bars) air supply (equivalent volume = 9 cfh [0.26 cmh]).

NOTE: ADC reserves the right to make changes in specifications at any time, without notice or obligation.

17

Image 21
Contents QUE Faire SI Vous Sentez UNE Odeur DE GAZ What do YOU do if YOU Smell GASPour Votre Sécurité For Your SafetyFor Your Safety Page Table of Contents Air Blower Drive System Cleaning Adjustments LubricationML-410 Reference Guide Page ML-410 Machine Operational Summary ML-410 Operator CONTROLS/INDICATORSEND of CYCLE/AIR JET JOG Forward/Reverse Push-ButtonsML-410 Machine Operation Troubleshooting Information END of CYCLE/HEATER Fault IndicatorAIR JET Unload Tilted Load TiltedIf this selection does not operate ONE or Both Burners do not Ignite DRYImportant Information GAS PressureONE Burner will not Ignite During a Drying Cycle ONE Burner will not Ignite AT the Beginning of a CycleSystem Ladder Diagram Tumbler Temperature and HI-LIMIT InformationFront Level Switch Rear Level Switch Optional Sprinkler Control Signals Section What to do if YOU Smell GAS Safety PrecautionsStandards Specifications and Dimensions 410 Tilting Clearance Allow Ances DimensionsML-410 1 Door/2-Way Tilt ML-410 1 Door/2-Way Tilt MLS-410 1 Door/2-Way Tilt ML-410 1 Door/2-Way Tilt With Inlet Air Adapter Reassembly of Dryer Installation ProceduresMLG-410 1 Door/Forward Tilt with Sprinkler Important the Flex Hose Must not be Kinked MLG-410 1 Door/Forward Tilt With Sprinkler MLS-410 2 Door/2-Way Tilt Refer to Tilting Piston Reconnection View on MLS-410 2 Door/2-Way Tilt Fresh AIR Supply Requirements Exhaust Requirements Compressed AIR Supply System Page Optional Automatic Piston Operated Load/Unload Doors Electrical InformationOptional Sprinkler Valve Electrical RequirementsMLG-410 Gas MLS-410 Steam Electrical Service SpecificationsMain Grounding GAS Information Type of Gas Technical Gas Data Gas SpecificationsPiping /Connections Page Steam Requirements High Pressure Steam InformationPage Steam Damper Air System Connections Air RequirementsAir Connections Air connection to system --- 1/8-inch N.P.T Steam Damper System Operation Water Supply Connection for Optional Sprinkler System Steam Damper Air Piston Flow Control Operation AdjustmentPreoperational Tests Heat Circuit Operational Test a. Gas Models Natural GASBasket Coating Preparation for OPERATION/START-UPShut Down Instructions Parts ServiceReturning Warranty Parts Returning Warranty CardsPage Cleaning Routine MaintenanceMonthly Lubrication AdjustmentsTumbler Basket Drive System Component System DescriptionsTumbler Basket Manual Reset Hi-Limit Safety Thermostat Safety DevicesTumbler Basket AIR Blower Drive SystemSail Switches for Gas Dryers Only Steam Damper Actuator System Optional Sprinkler Circuit Components Optional Sprinkler System ComponentsRefer to the Dryer Nameplate for voltage rating information ML-410 Sprinkler Option Temperature Controller Settings ADC 113128 1- 03/13/00-25