4.Burner Box Manual Reset
These disc temperature switches have a setting of 330º F (165º C). They are located on the right side of each burner box, and they are a manual reset type of switch. These switches ensure that there is proper airflow through the burner box. Upon a low airflow condition, which may be caused by a clogged lint screen, excessively long or blocked exhaust duct, or improper
5.Sail Switches (for Gas Dryers Only)
These sail switches are located in the front and back of the burner boxes. A sail switch consists of a round damper plate on a lever arm which is in contact with an electric switch. When the air blower comes on, it draws air through the gas burners. This creates a negative pressure inside the burner boxes. This negative pressure pulls in the round dampers and activates the sail switches. If there is an improper (low) airflow through the dryer, the sail switch dampers will not pull in, preventing the heat from coming on and the Phase 7 will display either “front sail switch close fault” or “rear sail switch close fault.”
Low airflow through the dryer will be caused by overly long or block exhaust ducting, lack of
58