F. STEAM DAMPER ACTUATOR SYSTEM
The system consists of a hinged damper plate, two (2) pneumatic pistons (each with its’ own airflow needle valve) to control the speed of both pistons actuation, and a 24 volt solenoid valve.
On a call for heat, a 24 volt signal is applied to the
When the temperature set point has been reached, the 24 volt signal is removed from the solenoid valve, so that the solenoid valve blocks the air supply to the pistons, and the air in the pistons is bled to atmosphere. The springs in the pistons now retract the piston rods, closing the steam damper. The steam damper plate now covers the steam coil and allows room air to bypass the coil before entering the tumbler (basket) for a rapid cool down.
The steam damper plate should open and close slowly and smoothly. The speed can be modulated by adjusting both needle valve knobs. Turning the knob clockwise (CW) restricts the compressed airflow and slows down the steam damper movement. Counterclockwise (CCW) adjustment speeds up the steam damper motion. Upon completion of adjustment, tighten the needle valve’s locking nut.
NOTE: Turning the knob on the FLOW CONTROL VALVE clockwise (CW) will restrict airflow. Turning the knob on the FLOW CONTROL VALVE counterclockwise (CCW) will allow higher airflow.
59