American Dryer Corp ML-410 manual Important the Flex Hose Must not be Kinked

Page 29

1.Reassembly for the MLG-410 1 Door/Forward Tilt with Sprinkler Gas Model Dryer...

Lift the tumbler (basket) section onto the base...

a.Forward tilting dryers have two (2) tilting pistons located in the rear corners of the dryer base and two

(2) piston posts located in the front corners of the dryer base. On the top of the tilting pistons and tilting posts are clevis block. Use the eight (8) 1/2” x 1-1/4” hex head bolts and lock washers (supplied with the dryer) to secure each clevis block to the bottom of the tumbler (basket) section.

Refer to Tilting Piston Reconnection View on page 26.

Refer to Tilting Post Reconnection View on page 26.

b.The gas line is disconnected at the union when the dryer is shipped in two (2) pieces. This gas line union is located in the right side of the dryer base. Insert the gas line union half way through the hole on the bottom of the tumbler (basket) section. Connect the two (2) union halves and retighten.

IMPORTANT: THE FLEX HOSE MUST NOT BE KINKED.

2.There are two (2) electrical reconnections:

a.A plug and cable is located in the right side of the base. This must be lifted up and reconnected into the mating socket located at the bottom of the right tumbler section.

b.The tumbler section power cable must be lifted up from the base and reconnected into the junction box next to the tumbler drive motor in the left side of the tumbler section.

Make sure both reconnected cables have enough slack in them to allow the dryer to tilt freely in both directions.

IMPORTANT: THE RECONNECTED ELECTRICAL CABLES MUST HAVE ENOUGH SLACK IN THEM TO ALLOW THE DRYER TO TILT FREELY IN BOTH DIRECTIONS.

c.Reattach The Tilt Guard Panel...

1)Use the 1/4-20 x 3/8” hex head bolts and lock washers (supplied with the dryer) to secure the top of the front tilt guard into the bottom of the front of the tumbler (basket) section.

2)Use the 1/4-20 x 3/8” hex head bolts and lock washers (supplied with the dryer) to secure the top of the rear tilt guard to the bottom of the rear of the tumbler (basket) section.

3)Use the 1/4-20 self-tapping screws (supplied with the dryer) to secure the right side tilt guards and left side tilt guards.

4)Reconnect the spring and claw assembly which connects the rear tilt guard to each side tilt guard.

5)Reconnect both chains to the back panel...the spring keeps the rear guard close to the dryers’ back as the dryer is tilted forward or backwards. (Refer to Tilt Guard Reconnection View on page 26.)

25

Image 29
Contents QUE Faire SI Vous Sentez UNE Odeur DE GAZ What do YOU do if YOU Smell GASPour Votre Sécurité For Your SafetyFor Your Safety Page Table of Contents Air Blower Drive System Cleaning Adjustments LubricationML-410 Reference Guide Page ML-410 Machine Operational Summary ML-410 Operator CONTROLS/INDICATORSEND of CYCLE/AIR JET JOG Forward/Reverse Push-ButtonsAIR JET ML-410 Machine Operation Troubleshooting InformationEND of CYCLE/HEATER Fault Indicator If this selection does not operate Unload TiltedLoad Tilted ONE or Both Burners do not Ignite DRYImportant Information GAS PressureONE Burner will not Ignite During a Drying Cycle ONE Burner will not Ignite AT the Beginning of a CycleFront Level Switch Rear Level Switch System Ladder DiagramTumbler Temperature and HI-LIMIT Information Optional Sprinkler Control Signals Section What to do if YOU Smell GAS Safety PrecautionsStandards Specifications and Dimensions 410 Tilting Clearance Allow Ances DimensionsML-410 1 Door/2-Way Tilt ML-410 1 Door/2-Way Tilt MLS-410 1 Door/2-Way Tilt ML-410 1 Door/2-Way Tilt With Inlet Air Adapter Reassembly of Dryer Installation ProceduresMLG-410 1 Door/Forward Tilt with Sprinkler Important the Flex Hose Must not be Kinked MLG-410 1 Door/Forward Tilt With Sprinkler MLS-410 2 Door/2-Way Tilt Refer to Tilting Piston Reconnection View on MLS-410 2 Door/2-Way Tilt Fresh AIR Supply Requirements Exhaust Requirements Compressed AIR Supply System Page Optional Automatic Piston Operated Load/Unload Doors Electrical InformationOptional Sprinkler Valve Electrical RequirementsMLG-410 Gas MLS-410 Steam Electrical Service SpecificationsMain Grounding GAS Information Type of Gas Technical Gas Data Gas SpecificationsPiping /Connections Page Steam Requirements High Pressure Steam InformationPage Air Connections Air connection to system --- 1/8-inch N.P.T Steam Damper Air System ConnectionsAir Requirements Steam Damper System Operation Water Supply Connection for Optional Sprinkler System Steam Damper Air Piston Flow Control Operation AdjustmentPreoperational Tests Heat Circuit Operational Test a. Gas Models Natural GASBasket Coating Preparation for OPERATION/START-UPShut Down Instructions Parts ServiceReturning Warranty Parts Returning Warranty CardsPage Cleaning Routine MaintenanceMonthly Lubrication AdjustmentsTumbler Basket Drive System Component System DescriptionsTumbler Basket Manual Reset Hi-Limit Safety Thermostat Safety DevicesTumbler Basket AIR Blower Drive SystemSail Switches for Gas Dryers Only Steam Damper Actuator System Optional Sprinkler Circuit Components Optional Sprinkler System ComponentsRefer to the Dryer Nameplate for voltage rating information ML-410 Sprinkler Option Temperature Controller Settings ADC 113128 1- 03/13/00-25