4.Steam Damper Air System Connections

The MLS-410 is manufactured with a pneumatic (piston) damper system which requires an external supply of compressed air. The connection is made at the left hand side on top of the dryer.

a. Air Requirements

Compressed Air Supply

 

Air Pressure

 

 

 

 

Normal

 

80 PSI

5.51 bars

 

 

 

 

Minimum Supply

 

70 PSI

4.82 bars

 

 

 

 

Maximum Supply

 

90 PSI

6.20 bars

 

 

 

 

Shaded areas are stated in metric equivalents

 

 

b.Air Connections

Air connection to system --- 1/8-inch N.P.T.

c.No air regulation is provided with a standard ML-410 dryer. External regulation of 80 PSI (5.512 bars) must be provided. It is suggested that a filter/regulator assembly (with gauge) be added to the compressed air line just before the dryer connection. This is necessary to insure that correct and clean air pressure is achieved. The filter/regulator assembly (with gauge) is provided on dryers with the AUTOMATIC DOOR, TILTING, or SPRINKLER CIRCUIT OPTION.

43

Image 47
Contents QUE Faire SI Vous Sentez UNE Odeur DE GAZ What do YOU do if YOU Smell GASPour Votre Sécurité For Your SafetyFor Your Safety Page Table of Contents Air Blower Drive System Cleaning Adjustments LubricationML-410 Reference Guide Page ML-410 Machine Operational Summary ML-410 Operator CONTROLS/INDICATORSEND of CYCLE/AIR JET JOG Forward/Reverse Push-ButtonsAIR JET ML-410 Machine Operation Troubleshooting InformationEND of CYCLE/HEATER Fault Indicator If this selection does not operate Unload TiltedLoad Tilted ONE or Both Burners do not Ignite DRYImportant Information GAS PressureONE Burner will not Ignite During a Drying Cycle ONE Burner will not Ignite AT the Beginning of a CycleFront Level Switch Rear Level Switch System Ladder DiagramTumbler Temperature and HI-LIMIT Information Optional Sprinkler Control Signals Section What to do if YOU Smell GAS Safety PrecautionsStandards Specifications and Dimensions 410 Tilting Clearance Allow Ances DimensionsML-410 1 Door/2-Way Tilt ML-410 1 Door/2-Way Tilt MLS-410 1 Door/2-Way Tilt ML-410 1 Door/2-Way Tilt With Inlet Air Adapter Reassembly of Dryer Installation ProceduresMLG-410 1 Door/Forward Tilt with Sprinkler Important the Flex Hose Must not be Kinked MLG-410 1 Door/Forward Tilt With Sprinkler MLS-410 2 Door/2-Way Tilt Refer to Tilting Piston Reconnection View on MLS-410 2 Door/2-Way Tilt Fresh AIR Supply Requirements Exhaust Requirements Compressed AIR Supply System Page Electrical Requirements Electrical InformationOptional Automatic Piston Operated Load/Unload Doors Optional Sprinkler ValveMLG-410 Gas MLS-410 Steam Electrical Service SpecificationsMain Grounding GAS Information Type of Gas Technical Gas Data Gas SpecificationsPiping /Connections Page Steam Requirements High Pressure Steam InformationPage Air Connections Air connection to system --- 1/8-inch N.P.T Steam Damper Air System ConnectionsAir Requirements Steam Damper System Operation Water Supply Connection for Optional Sprinkler System Steam Damper Air Piston Flow Control Operation AdjustmentPreoperational Tests Heat Circuit Operational Test a. Gas Models Natural GASBasket Coating Preparation for OPERATION/START-UPShut Down Instructions Parts ServiceReturning Warranty Parts Returning Warranty CardsPage Cleaning Routine MaintenanceMonthly Lubrication AdjustmentsTumbler Basket Drive System Component System DescriptionsAIR Blower Drive System Safety DevicesTumbler Basket Manual Reset Hi-Limit Safety Thermostat Tumbler BasketSail Switches for Gas Dryers Only Steam Damper Actuator System Optional Sprinkler Circuit Components Optional Sprinkler System ComponentsRefer to the Dryer Nameplate for voltage rating information ML-410 Sprinkler Option Temperature Controller Settings ADC 113128 1- 03/13/00-25