GAS PRESSURE

The natural gas pressure supplied to the dryer must be between 6-inches (14.92 mb) and 12-inches of W.C. (water column) - 29.9 mb - pressure. If the supply pressure is above 12-inches water column (29.9 mb) than an external regulator must be installed to reduce the gas supply pressure to between 6-inches (14.92 mb) and 12- inches of water column (29.9 mb).

Once the flame has been established in both burner boxes, the natural gas outlet manifold pressure measured at each gas valve pressure tap must be 3.5-inches W.C. (water column) - 8.7 mb - pressure. Connect a water tube manometer to the 1/8” F.P.T. gas pressure tap on the downstream side of each gas valve. There is a pressure regulator in both gas valves so the manifold pressure can be adjusted to 3.5-inches water column (8.7 mb). Unscrew the slotted regulator cover which is located on the top of each gas valve, and turn the regulator adjustment screw located underneath the cover (clockwise [CW] to increase manifold pressure and counterclockwise [CCW] to decrease manifold pressure).

The L.P. (liquid propane) gas pressure measured at each gas valve pressure tap must be 11-inches water column (27.4 mb) pressure, when the flame is established in both burner boxes. There is no means to adjust this pressure supplied with the dryer so the downstream L.P. pressure regulator must be adjusted to provide the 11-inch water column (27.4 mb) outlet manifold pressure. Connect a water tube manometer to the 1/8” F.P.T. gas pressure tap on the downstream side of each gas valve to measure the manifold pressure.

IMPORTANT INFORMATION

Once the Blower Motor starts, both the FRONTAIRFLOW SWITCH and the REAR AIRFLOW SWITCH must pull in to indicate that there is sufficient airflow through the machine for safe ignition of both the Front Burner and the Rear Burner.

10

Image 14
Contents What do YOU do if YOU Smell GAS QUE Faire SI Vous Sentez UNE Odeur DE GAZFor Your Safety Pour Votre SécuritéFor Your Safety Page Table of Contents Cleaning Adjustments Lubrication Air Blower Drive SystemML-410 Reference Guide Page ML-410 Operator CONTROLS/INDICATORS ML-410 Machine Operational SummaryJOG Forward/Reverse Push-Buttons END of CYCLE/AIR JET AIR JET ML-410 Machine Operation Troubleshooting Information END of CYCLE/HEATER Fault Indicator If this selection does not operate Unload TiltedLoad Tilted DRY ONE or Both Burners do not IgniteGAS Pressure Important InformationONE Burner will not Ignite AT the Beginning of a Cycle ONE Burner will not Ignite During a Drying CycleFront Level Switch Rear Level Switch System Ladder DiagramTumbler Temperature and HI-LIMIT Information Optional Sprinkler Control Signals Section Safety Precautions What to do if YOU Smell GASStandards Specifications and Dimensions Dimensions 410 Tilting Clearance Allow AncesML-410 1 Door/2-Way Tilt ML-410 1 Door/2-Way Tilt MLS-410 1 Door/2-Way Tilt ML-410 1 Door/2-Way Tilt With Inlet Air Adapter Installation Procedures Reassembly of DryerMLG-410 1 Door/Forward Tilt with Sprinkler Important the Flex Hose Must not be Kinked MLG-410 1 Door/Forward Tilt With Sprinkler MLS-410 2 Door/2-Way Tilt Refer to Tilting Piston Reconnection View on MLS-410 2 Door/2-Way Tilt Fresh AIR Supply Requirements Exhaust Requirements Compressed AIR Supply System Page Optional Sprinkler Valve Electrical InformationOptional Automatic Piston Operated Load/Unload Doors Electrical RequirementsElectrical Service Specifications MLG-410 Gas MLS-410 SteamMain Grounding GAS Information Technical Gas Data Gas Specifications Type of GasPiping /Connections Page Steam Information Steam Requirements High PressurePage Air Connections Air connection to system --- 1/8-inch N.P.T Steam Damper Air System ConnectionsAir Requirements Steam Damper System Operation Steam Damper Air Piston Flow Control Operation Adjustment Water Supply Connection for Optional Sprinkler SystemPreoperational Tests Natural GAS Heat Circuit Operational Test a. Gas ModelsPreparation for OPERATION/START-UP Basket CoatingShut Down Instructions Service PartsReturning Warranty Cards Returning Warranty PartsPage Routine Maintenance CleaningMonthly Adjustments LubricationComponent System Descriptions Tumbler Basket Drive SystemTumbler Basket Safety DevicesTumbler Basket Manual Reset Hi-Limit Safety Thermostat AIR Blower Drive SystemSail Switches for Gas Dryers Only Steam Damper Actuator System Optional Sprinkler System Components Optional Sprinkler Circuit ComponentsRefer to the Dryer Nameplate for voltage rating information ML-410 Sprinkler Option Temperature Controller Settings ADC 113128 1- 03/13/00-25