Frigidaire 137101400 installation instructions Maximum Length

Page 4

- Risk of Fire - A clothes dryer must be ex- hausted outdoors. Do not exhaust dryer into a chimney, a wall, a ceiling, an attic, a crawl space or any concealed space of a building. A clothes dryer produces combustible lint. If the dryer is not exhausted outdoors, some fine lint will be expelled into the laundry area. An accumulation of lint in any area of the home can create a health and fire hazard. The dryer must be connected to an exhaust outdoors. Regularly inspect the outdoor exhaust opening and remove any accumulation of lint around the outdoor exhaust opening and in the surrounding area.

Do not allow combustible materials (for ex- ample: clothing, draperies/curtains, paper) to come in con- tact with exhaust system. The dryer MUST NOT be exhausted into a chimney, a wall, a ceiling, or any concealed space of a building which can accumulate lint, resulting in a fire hazard.

Exceeding the length of duct pipe or num- ber of elbows allowed in the "MAXIMUM LENGTH" charts can cause an accumulation of lint in the exhaust system. Plug- ging the system could create a fire hazard, as well as increase drying times.

Do not screen the exhaust ends of the vent system, nor use any screws, rivets or other fastening means that extend into the duct and catch lint to assemble the exhaust system. Lint can become caught in the screen, on the screws or rivets, clogging the duct work and creating a fire haz- ard as well as increasing drying times. Use an approved vent hood to terminate the duct outdoors, and seal all joints with duct tape. All male duct pipe fittings MUST be installed downstream with the flow of air.

Explosion hazard. Do not install the dryer where gasoline or other flammables are kept or stored. If the dryer is installed in a garage, it must be a minimum of 18 inches (45.7 cm) above the floor. Failure to do so can result in death, explosion, fire or burns.

 

 

MAXIMUM LENGTH

 

 

of 4” (10.2 cm) Dia. Rigid Metal Duct

 

 

 

 

 

 

 

 

 

VENT HOOD TYPE

 

Number

 

(Preferred)

 

 

 

of

 

 

 

Louvered

 

 

90°

 

 

 

 

 

 

Turns

 

 

 

 

 

 

 

 

4”

 

 

2½"

 

(10.2 cm)

 

 

(6.35 cm)

0

60

ft.(18.28 m)

 

48 ft.(14.63 m)

1

52

ft.(15.84 m)

 

40 ft.(12.19 m)

2

44

ft.(13.41 m)

 

32 ft.

(9.75 m)

3

32

ft.(9.75 m)

 

24 ft.

(7.31 m)

4

28

ft.(8.53 m)

 

16 ft.

(4.87 m)

 

 

 

 

 

 

 

 

 

MAXIMUM LENGTH

 

Number

of 4” (10.2 cm) Dia. Flexible Metal Duct

 

VENT HOOD TYPE

 

of

 

 

 

(Preferred)

 

 

 

90°

 

 

 

 

 

 

 

Louvered

 

Turns

 

 

 

 

 

 

 

 

 

 

 

4”

 

2½"

 

(10.2 cm)

 

(6.35 cm)

0

30 ft.

(9.14 m)

18 ft. (5.49 m)

1

22 ft.

(6.71

m)

14 ft. (4.27 m)

2

14 ft.

(4.27

m)

10 ft. (3.05 m)

3

 

 

NOT RECOMMENDED

CORRECT INCORRECT

INSTALL MALE FITTINGS IN CORRECT DIRECTION

In installations where the exhaust system is not described in the charts, the following method must be used to determine if the exhaust system is acceptable:

1.Connect an inclined or digital manometer between the dryer and the point the exhaust connects to the dryer.

2.Set the dryer timer and temperature to air fluff (cool down) and start the dryer.

3.Read the measurement on the manometer.

4.The system back pressure MUST NOT be higher than 0.75 inches of water column. If the system back pressure is less than 0.75 inches of water column, the system is acceptable. If the manometer reading is higher than 0.75 inches of water column, the system is too restrictive and the installation is unacceptable.

Although vertical orientation of the exhaust system is acceptable, certain extenuating circumstances could affect the performance of the dryer:

Only the rigid metal duct work should be used.

4

Image 4
Contents Installation Instructions Safety Instructions PRE-INSTALLATION RequirementsElectrical Requirements GAS Supply RequirementsExhaust System Requirements Electric DryerMaximum Length Location of Your Dryer Dryer Installation Dimensions General Installation Replacement PartsUnpacking Reversing Door Swing Mobile Home InstallationSolid Door Reversing Instructions Window Door Reversal Instructions Page GAS Connection Electrical InstallationGrounding Requirements Electrical Connections For 3-WIRE System Electrical Connections for 4-WIRE SystemAvant L’INSTALLATION Outils et matériel requis pour l’installation14-16 19-21Installation Électrique Alimentation EN GAZÉvacuation DE L’AIR Alimentation ÉlectriqueLongueur Maximum Poser LES Raccords Mâles Dans LA Bonne DirectionEmplacement DE LA Sécheuse Emplacement DES Bouches D’ÉVACUATIONNE PAS Installer LA Sécheuse Installation Dans UNE Alcôve OU UN PlacardDimensions D’Installation De Secheuse Installation DéballagePièces DE Rechange Emballage Morceau DE MousseInstallation Dans UNE Maison Mobile Porte RéversibleInstructions pour inverser la porte Page Branchement DU GAZ Sécheuses Électriques non-CanadiennesNe modifiez pas la prise équipée d’appareil Sécheuses Électriques CanadiennesBranchement Électrique D’UNE Installation À 3 Fils Branchement Électrique D’UNE Installation À 4 FilsRequerimientos DE Instalación Preliminares InstruccionesQUE Debe Hacer SI Percibe Olor a GAS Herramientas y materiales necesarios para la instalaciónRequerimientos Eléctricos Requerimientos DEL Suministro DE GASSecadoras Eléctricas Nema 10-30R Nema 14-30RDe 4 10,2 cm de Diámetro PreferidoDel Conducto Metálico Flexible De 4 10,2 cm de Diámetro Tipo DE Caperuza DE SalidaUbicación DE SU Secadora Ubicación DEL EscapeNo Instale SU Secadora Instalación Dentro DE UN Nicho O ArmarioDimensiones de la Instalación Modelos Autónomos CON Consola DesembalajeGeneral Instalación Piezas DE RecambioInstalación EN Casas Móviles Puerta ReversiblePage Page Conexión DEL GAS Instalación EléctricaPara Detectar SI HAY Fugas DE GAS Conexiónes Eléctricas Para UN Sistema Trifilar Secadoras Eléctricas No Canadienses