Safety Devices | Location | Function | Computer | Result of | |
Display Message | Tripping | ||||
|
|
| |||
Load Door Switch | Left side of | Insures dryer load | "DOOR OPEN" | Dryer will not | |
Load door | doors are closed | run | |||
|
| ||||
|
|
|
|
| |
Unload Door Switch | Right side of | Insures dryer unload | "DOOR OPEN" | Dryer will not | |
unload door | doors are closed | run | |||
| |||||
|
|
|
|
| |
| Top left side |
|
| Dryer will not | |
Tilting Switches | of base | Insures dryer is level | "LEVEL FAULT" | ||
run | |||||
| module |
|
| ||
|
|
|
| ||
|
|
|
|
| |
| Left side of | Insures tumbler is |
|
| |
Drum Rotation Sensor | tumbler | "DRUM FAULT" | Stops heat only | ||
rotating | |||||
| section |
|
| ||
|
|
|
| ||
|
|
|
|
| |
Lint Chamber Air | Center of | Insures proper air | "AIRFLOW | Stops heat only | |
Pressure Switch | heat console | flow through dryer | FAULT" | ||
| |||||
|
|
|
|
| |
Burner Fan Air Flow | Center of | Insures proper |
|
| |
Switch | combustion air flow | "HEATER FAULT" | Stops heat only | ||
heat console | |||||
(Gas Dryers Only) | into the burner box |
|
| ||
|
|
| |||
|
|
|
|
| |
Hi/Lo Gas Pressure | Lower left of | Insures proper gas | "GAS SUPPLY |
| |
Switch | heat console | supply pressure for | Stops heat only | ||
FAULT" | |||||
(Gas Dryers Only) | section | adequate ignition |
| ||
|
| ||||
|
|
|
|
| |
Heat Reclaimer | Right Side of | Insures that the heat | Input LED #13 of | None | |
reclaimer is either | |||||
Damper Switch | heat console | the PLC is off | |||
opened or closed |
| ||||
|
|
|
| ||
|
|
|
|
| |
Heat Console Door | Inside Heat | Insures that access | "DOOR OPEN" | Dryer will not | |
Access Door Switch | Console | doors are closed | run | ||
| |||||
|
|
|
|
| |
Exhaust Air Temp | Inside Burner | Monitors tumbler | "EXHAUST | Stops heat only | |
Control Sensor | section duct | exhaust air temp | DSFL" | ||
| |||||
|
|
|
|
| |
Exhaust Air Hi Temp | Inside exhaust | Monitors tumbler |
| Stops heat only | |
Control Sensor | duct | exhaust and air temp | FAULT" | ||
| |||||
|
|
|
|
| |
Intake Air Temp | Top right of | Monitors tumbler air |
|
| |
Control Sensor | tumbler | "INTAKE DSFL" | Stops heat only | ||
intake temp | |||||
(optional) | section |
|
| ||
|
|
| |||
|
|
|
|
| |
Intake Air Temp | Top right of | Monitors tumbler air |
| ||
tumbler | Stops heat only | ||||
Control Sensor | intake temp | FAULT" | |||
section |
| ||||
|
|
|
| ||
|
|
|
|
| |
Burner | Top of burner | Monitors air temp | Stops heat only | ||
Sensor | section | above the burner box | FAULT" | ||
| |||||
|
|
|
|
| |
| Top right of |
|
| Opens the | |
Sprinkler Control | Open sprinkler | Orange sprinkler pilot | srpinkler water | ||
tumbler | system water valve on | light comes on. | valve and power | ||
Safety Sensor | |||||
section | Alarm horn sounds | down the whole | |||
| |||||
|
|
|
| dryer | |
|
|
|
|
| |
|
| Disables machine |
|
| |
| Above lint | when drawers are |
| Dryer will not | |
Lint Drawer Switches | drawer | open or if drawers | Lint Drawer | ||
have not been | run | ||||
| handles |
| |||
| cleaned in last five |
|
| ||
|
| loads |
|
| |
|
|
|
|
|
47