If no voltage is measured;

Start a drying cycle, and monitor the voltages on TB1-23 and 9.

If a voltage is present during drying start-up, the switch is functioning.

If a voltage is not present while the dryer is started, check:

Air Switch Adjustment.

Switch.

Circuitry (AD-464 Main Wiring Diagram and AD-464 Solenoid Junction Box Wiring Diagram). 3b) To check the electrical actuating of the pilot gas valve.

Shut the main gas valve to the dryer.

Open the disconnect block on TB1-63, for circuit testing. With control voltage “ON”, apply a 100 VAC line to TB1-63. THE PILOT GAS VALVE SOLENOID SHOULD ACTIVATE.

If the solenoid does not cycle check circuitry; ADG-464 Main Wiring Diagram, and ADG-464 Solenoid Junction Box Wiring Diagram.

Check gas valve solenoid.

Retest.

With the main gas valve OPEN, close disconnect block on TB1-63 and Measure for 110 VAC on TB1-63 and TB1-9 on the Main Electrical Panel during a drying cycle start-up.

If a 110 VAC is present during start-up, burner pilot output circuit is OK.

If a 110 VAC is not present;

Check circuitry; refer to ADG-464 Main Panel Wiring Diagram and ADG-464 Solenoid Junction Box Wiring Diagram).

Refer to Section VI, Part D, Gas Burner and Ignition System on page 37 thru page 45. 4b) To check the electrical actuation of the Ignition Transformer;

Shut the main gas valve to the dryer.

Open the disconnect block on TB1-65, for circuit testing with control voltage “ON”, apply a 110 VAC line to TB1-65 “output” ARCHING SHOULD OCCUR AT THE SPARK IGNITER IN THE BURNER ASSEMBLY.

If there is arcing, close disconnect on TB1-65.

67

Image 71
Contents ADG-464 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Troubleshooting TOC Service PartsReturning Warranty Cards Parts Returning Warranty Parts Section What to do if YOU Smell GAS Safety PrecautionsPage Specifications SPECIFICATIONS/DIMENSIONSDimensions Reassembly of Dryer Installation ProceduresPage Page Location Requirements Internal AIR, Electric and Water Connections Page Page Page Page Page Left Drum Motor External Supply Connections Page Page Electrical Requirements Electrical RequirementsElectrical Service Specifications PER Dryer Page Fresh AIR Supply Requirements Preparation for Operation PRE START-UPCleaning Routine MaintenanceMonthly Component System Descriptions Page Page Main AIR Blower and Heat Reclaimer System Page Additives or Solvents Compressed AIR SystemPage Page GAS Burner and Ignition System Switch #1 Recycling Mode Page Page Page Page Page Page Page Safety Devices Level Fault Parts ServiceReturning Warranty Parts Returning Warranty CardsWarranty Page Troubleshooting Probable Causes Power MalfunctionsPossible Solutions No Control Power Blue Light Off Machine Main Power Shuts Down Blue Indicator Off 2CRB Sprinkler Circuit Description Page If no, go to on Possible Solutions Unless the Water Valve to the Sprinkler is Closed General DescriptionBurner Section Input Circuit Component Description Burner Controller Input Signal ComponentsBurner Ignition IntroductionLoad Door Switch DS1B Stop Detector Relay Contact SMD no Output Signal Component Description GAS Fault Message gas system only Heater Fault Message Possible Solutions Page Page AIR Fault Message HI-TEMP Fault Message Possible Solutions Drum Fault Message Page Tumbler Basket Section Electrical Components Tumbler Basket Section Electrical MalfunctionsFollowing is for 2-Door Models only Rear Panel Control Problems Probable Causes Possible Solutions PLC OUT PIN 7 = Unload Door Open PLC OUT PIN 10 = Front UP Unload 1 Selection Probable CausesDoor Open Problem Drum Fault Message Malfunction Probable Causes Page Base Section Electrical Malfunctions Front Door SwitchRear Down Switch LS2 Lint Drawer Proximity SwitchesProbable Solutions Lint Chamber Pressure Switch PS3Tumbler Basket Tilt Problems Level Fault Page Lint Screen Mechanism Problem Screen Fault Lint Chamber Air Pressure Problem AIR Fault Pendant Electrical Components Pendant Control MalfunctionsVerify Pendant Electrical Signals Wiring Diagram Temperature Sensing Page Temperature Measurement and Sensing Problems Motors Circuit Wiring to the Analog Input ModuleMotor Protection Device Descriptions Motor Actuation Problems Probable CausesBurner Controller stops heat PLC Programmable Logic Controller Error Messages