American Dryer Corp ADG-464 manual Possible Solutions, Rear Panel Control Problems Probable Causes

Page 80

b)POSSIBLE SOLUTIONS;

1a) If the EMERGENCY STOP (E-Stop) - rear - does not respond:

Verify that ALL other EMERGENCY STOP (E-Stop) buttons are pulled out.

Verify that the rear panel’s disconnect plug is indeed connected. The disconnect plug is to allow the removal of the rear panel for drying servicing.

2b) Defective EMERGENCY STOP (E-Stop) Switch

Shut power off (main breaker) remove the rear panel and check switch using an OHM meter; replace if defective.

Retest

3b) Wiring Back to Main Electrical Enclosure

Shut power to the AD-464 dryer (Main Breaker).

Open “disconnects” on terminal #16 and terminal #17 of TB1; These disconnects are located on the bottom of the main electrical enclosure.

Connect an OHM meter to the output side of terminal #16 and terminal #17 of TB1.

Push in the EMERGENCY STOP (E-Stop) button (opening the switch)

Does the previous test show that there’s a switch closure opening?

If yes, refer to paragraph 3b above.

If no, refer to paragraph 4b below.

4b) Wiring from the EMERGENCY STOP (E-Stop) button to the main electrical enclosure is OK.

Check REAR PANEL CONTROLS WIRING DIAGRAM

Check TUMBLER JUNCTION BOX WIRING DIAGRAM

See paragraph 3a above and retest

3.Rear Panel Control Problems

a)PROBABLE CAUSES;

1a) Rear Panel Disconnect Plug.

2a) Defective Switches.

3a) Wiring back to the main electrical enclosure.

76

Image 80
Contents ADG-464 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Troubleshooting TOC Service PartsReturning Warranty Cards Parts Returning Warranty Parts Section Safety Precautions What to do if YOU Smell GASPage SPECIFICATIONS/DIMENSIONS SpecificationsDimensions Installation Procedures Reassembly of DryerPage Page Location Requirements Internal AIR, Electric and Water Connections Page Page Page Page Page Left Drum Motor External Supply Connections Page Page Electrical Requirements Electrical RequirementsElectrical Service Specifications PER Dryer Page Fresh AIR Supply Requirements PRE START-UP Preparation for OperationRoutine Maintenance CleaningMonthly Component System Descriptions Page Page Main AIR Blower and Heat Reclaimer System Page Compressed AIR System Additives or SolventsPage Page GAS Burner and Ignition System Switch #1 Recycling Mode Page Page Page Page Page Page Page Safety Devices Level Fault Service PartsReturning Warranty Parts Returning Warranty CardsWarranty Page Troubleshooting Probable Causes Power MalfunctionsPossible Solutions No Control Power Blue Light Off Machine Main Power Shuts Down Blue Indicator Off 2CRB Sprinkler Circuit Description Page If no, go to on Possible Solutions General Description Unless the Water Valve to the Sprinkler is ClosedBurner Controller Input Signal Components Burner IgnitionIntroduction Burner Section Input Circuit Component DescriptionLoad Door Switch DS1B Output Signal Component Description Stop Detector Relay Contact SMD noGAS Fault Message gas system only Heater Fault Message Possible Solutions Page Page AIR Fault Message HI-TEMP Fault Message Possible Solutions Drum Fault Message Page Tumbler Basket Section Electrical Malfunctions Tumbler Basket Section Electrical ComponentsFollowing is for 2-Door Models only Rear Panel Control Problems Probable Causes Possible Solutions Unload 1 Selection Probable Causes PLC OUT PIN 7 = Unload Door Open PLC OUT PIN 10 = Front UPDoor Open Problem Drum Fault Message Malfunction Probable Causes Page Front Door Switch Rear Down Switch LS2Lint Drawer Proximity Switches Base Section Electrical MalfunctionsProbable Solutions Lint Chamber Pressure Switch PS3Tumbler Basket Tilt Problems Level Fault Page Lint Screen Mechanism Problem Screen Fault Lint Chamber Air Pressure Problem AIR Fault Pendant Control Malfunctions Pendant Electrical ComponentsVerify Pendant Electrical Signals Wiring Diagram Temperature Sensing Page Temperature Measurement and Sensing Problems Circuit Wiring to the Analog Input Module MotorsMotor Actuation Problems Probable Causes Motor Protection Device DescriptionsPLC Programmable Logic Controller Error Messages Burner Controller stops heat