American Dryer Corp ADG-464 manual No Control Power Blue Light Off

Page 57

If RTD (Resistive Temperature Device) probe is defective, replace the probe.

NOTE: If ALL systems check out fine, call the ADC Service Department at (508) 678-9000.

2.No Control Power (“BLUE” Light Off)

a.PROBABLE CAUSES;

1a) Line voltage from main fused disconnected.

2a) Main disconnect on the ADG-464 is turned off.

3a) OL11 (overload #11) tripped.

4a) Fuse #1 is blown.

b.POSSIBLE SOLUTIONS;

1b) Verify main line voltage to ADG-464

If line voltage is present go to paragraph #2b below.

If line voltage is not present check fused disconnect and retest.

2b) Attempt to turn the ADG-464 main power handle to the “ON” position.

If the switch does not engage, verify that sprinkler power is “ON” (“RED” light on main door).

If “no,” refer to paragraph #1b above.

3)Open main enclosure and verify that OL11 has not tripped.

If yes, check circuit, restart and test.

If no go to section #3 on page 54.

Verify that fuse #1 has not blown, check that the “RED” L.E.D. indicator is off.

If “on” (fuse block L.E.D. “ON”), check circuit, replace fuse and test.

53

Image 57
Contents ADG-464 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Service Parts Returning Warranty Cards Parts Returning Warranty PartsTroubleshooting TOC Section What to do if YOU Smell GAS Safety PrecautionsPage Specifications SPECIFICATIONS/DIMENSIONSDimensions Reassembly of Dryer Installation ProceduresPage Page Location Requirements Internal AIR, Electric and Water Connections Page Page Page Page Page Left Drum Motor External Supply Connections Page Page Electrical Requirements Electrical RequirementsElectrical Service Specifications PER Dryer Page Fresh AIR Supply Requirements Preparation for Operation PRE START-UPCleaning Routine MaintenanceMonthly Component System Descriptions Page Page Main AIR Blower and Heat Reclaimer System Page Additives or Solvents Compressed AIR SystemPage Page GAS Burner and Ignition System Switch #1 Recycling Mode Page Page Page Page Page Page Page Safety Devices Level Fault Parts ServiceReturning Warranty Cards WarrantyReturning Warranty Parts Page Troubleshooting Power Malfunctions Possible SolutionsProbable Causes No Control Power Blue Light Off Machine Main Power Shuts Down Blue Indicator Off 2CRB Sprinkler Circuit Description Page If no, go to on Possible Solutions Unless the Water Valve to the Sprinkler is Closed General DescriptionBurner Ignition Burner Controller Input Signal ComponentsIntroduction Burner Section Input Circuit Component DescriptionLoad Door Switch DS1B Stop Detector Relay Contact SMD no Output Signal Component DescriptionGAS Fault Message gas system only Heater Fault Message Possible Solutions Page Page AIR Fault Message HI-TEMP Fault Message Possible Solutions Drum Fault Message Page Tumbler Basket Section Electrical Components Tumbler Basket Section Electrical MalfunctionsFollowing is for 2-Door Models only Rear Panel Control Problems Probable Causes Possible Solutions PLC OUT PIN 7 = Unload Door Open PLC OUT PIN 10 = Front UP Unload 1 Selection Probable CausesDoor Open Problem Drum Fault Message Malfunction Probable Causes Page Rear Down Switch LS2 Front Door SwitchLint Drawer Proximity Switches Base Section Electrical MalfunctionsLint Chamber Pressure Switch PS3 Tumbler Basket Tilt Problems Level FaultProbable Solutions Page Lint Screen Mechanism Problem Screen Fault Lint Chamber Air Pressure Problem AIR Fault Pendant Electrical Components Pendant Control MalfunctionsVerify Pendant Electrical Signals Wiring Diagram Temperature Sensing Page Temperature Measurement and Sensing Problems Motors Circuit Wiring to the Analog Input ModuleMotor Protection Device Descriptions Motor Actuation Problems Probable CausesBurner Controller stops heat PLC Programmable Logic Controller Error Messages