American Dryer Corp ADG-464 manual Possible Solutions

Page 81

b)POSSIBLE SOLUTIONS;

1b) If either the Drum forward or reverse functions (rear) don’t respond:

Verify that the rear panel controls disconnect plug is indeed connected. This disconnect plug allows for the removal of the rear control panel for dryer servicing.

2b) Defective Forward and Reverse Switch

Shut power off at the main breaker and remove the rear panel and check switches using an OHM meter; replace if defective.

Retest

3b) Wiring Back to Main Electrical Enclosure

With the control voltage “ON” front panel “GREEN” button

Select “1” on the “O UNLOAD 1” switch located on the rear controls panel.

Have someone PRESS either the forward or reverse buttons while you watch the input L.E.D.s (light emitting diode) of the programmable controller. Do the associated L.E.D.s light?

PLC PIN 20 = DRUM FWD., REAR PANEL PLC PIN 21 = DRUM REV., REAR PANEL

If yes, refer to paragraph 2 (section a) on page 75.

If no, refer to paragraph 2 (section b) on page 76.

4b) The L.E.D.s (light emitting diodes) illuminating on the PLC (Programmable Logic Controller) indicate that the wiring to the PLC is correct.

Check FUSE #2 on the Main Electrical Panel

Check wiring back to the Tumbler Junction Box

Check wiring back to the rear controls Refer to wiring diagrams:

Main Electrical Panel Diagram

Tumbler Junction Box Wiring Diagram

Rear Panel Controls Wiring Diagram

Retest

77

Image 81
Contents ADG-464 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Service Parts Returning Warranty Cards Parts Returning Warranty PartsTroubleshooting TOC Section What to do if YOU Smell GAS Safety PrecautionsPage Specifications SPECIFICATIONS/DIMENSIONSDimensions Reassembly of Dryer Installation ProceduresPage Page Location Requirements Internal AIR, Electric and Water Connections Page Page Page Page Page Left Drum Motor External Supply Connections Page Page Electrical Requirements Electrical RequirementsElectrical Service Specifications PER Dryer Page Fresh AIR Supply Requirements Preparation for Operation PRE START-UPCleaning Routine MaintenanceMonthly Component System Descriptions Page Page Main AIR Blower and Heat Reclaimer System Page Additives or Solvents Compressed AIR SystemPage Page GAS Burner and Ignition System Switch #1 Recycling Mode Page Page Page Page Page Page Page Safety Devices Level Fault Parts ServiceReturning Warranty Cards WarrantyReturning Warranty Parts Page Troubleshooting Power Malfunctions Possible SolutionsProbable Causes No Control Power Blue Light Off Machine Main Power Shuts Down Blue Indicator Off 2CRB Sprinkler Circuit Description Page If no, go to on Possible Solutions Unless the Water Valve to the Sprinkler is Closed General DescriptionBurner Ignition Burner Controller Input Signal ComponentsIntroduction Burner Section Input Circuit Component DescriptionLoad Door Switch DS1B Stop Detector Relay Contact SMD no Output Signal Component DescriptionGAS Fault Message gas system only Heater Fault Message Possible Solutions Page Page AIR Fault Message HI-TEMP Fault Message Possible Solutions Drum Fault Message Page Tumbler Basket Section Electrical Components Tumbler Basket Section Electrical MalfunctionsFollowing is for 2-Door Models only Rear Panel Control Problems Probable Causes Possible Solutions PLC OUT PIN 7 = Unload Door Open PLC OUT PIN 10 = Front UP Unload 1 Selection Probable CausesDoor Open Problem Drum Fault Message Malfunction Probable Causes Page Rear Down Switch LS2 Front Door SwitchLint Drawer Proximity Switches Base Section Electrical MalfunctionsLint Chamber Pressure Switch PS3 Tumbler Basket Tilt Problems Level FaultProbable Solutions Page Lint Screen Mechanism Problem Screen Fault Lint Chamber Air Pressure Problem AIR Fault Pendant Electrical Components Pendant Control MalfunctionsVerify Pendant Electrical Signals Wiring Diagram Temperature Sensing Page Temperature Measurement and Sensing Problems Motors Circuit Wiring to the Analog Input ModuleMotor Protection Device Descriptions Motor Actuation Problems Probable CausesBurner Controller stops heat PLC Programmable Logic Controller Error Messages