American Dryer Corp ADG-464 manual Drum Fault Message Malfunction Probable Causes

Page 84

If yes, wiring is OK:

Check switch placement and door actuation.

If no, check associated:

Switch and wiring

Check wiring back to the tumbler junction box

Check wiring back to the Rear Controls

Check PLC (Programmable Logic Controller) Refer to wiring diagrams:

Tumbler Junction Box Wiring Diagram

Rear Panel Controls Wiring Diagram

Retest; verify that the signal is operational

6.”DRUM FAULT MESSAGE” Malfunction

a)PROBABLE CAUSES;

1a) Stop Motion Detector Module or Sensor.

2a) Wiring back to Main Electrical Enclosure

b)POSSIBLE SOLUTIONS;

Open the Main Electrical Enclosure locate input #0, 10 on the PLC (Programmable Logic Controller). With control voltage “ON” (“GREEN” Push-Button), use the pendant to rotate the tumbler. Notice a L.E.D. (light emitting diode) on as the tumbler (basket) is rotating.

If the L.E.D. is off, refer to paragraph 6 (section a) above.

1b) If the L.E.D. (light emitting diode) is off:

Check Fuse #2; replace if necessary.

Rotate the tumbler using the pendant control, and adjust the stop.

Does the module’s L.E.D. (light emitting diode) respond?

If yes, adjust the “Time Adjust” until the LED is on during rotation 12 to 15 seconds after.

If no, check:

Inductive Proximity Sensor for Damage

80

Image 84
Contents ADG-464 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Service Parts Returning Warranty Cards Parts Returning Warranty PartsTroubleshooting TOC Section Safety Precautions What to do if YOU Smell GASPage SPECIFICATIONS/DIMENSIONS SpecificationsDimensions Installation Procedures Reassembly of DryerPage Page Location Requirements Internal AIR, Electric and Water Connections Page Page Page Page Page Left Drum Motor External Supply Connections Page Page Electrical Requirements Electrical RequirementsElectrical Service Specifications PER Dryer Page Fresh AIR Supply Requirements PRE START-UP Preparation for OperationRoutine Maintenance CleaningMonthly Component System Descriptions Page Page Main AIR Blower and Heat Reclaimer System Page Compressed AIR System Additives or SolventsPage Page GAS Burner and Ignition System Switch #1 Recycling Mode Page Page Page Page Page Page Page Safety Devices Level Fault Service PartsReturning Warranty Cards WarrantyReturning Warranty Parts Page Troubleshooting Power Malfunctions Possible SolutionsProbable Causes No Control Power Blue Light Off Machine Main Power Shuts Down Blue Indicator Off 2CRB Sprinkler Circuit Description Page If no, go to on Possible Solutions General Description Unless the Water Valve to the Sprinkler is ClosedBurner Controller Input Signal Components Burner IgnitionIntroduction Burner Section Input Circuit Component DescriptionLoad Door Switch DS1B Output Signal Component Description Stop Detector Relay Contact SMD noGAS Fault Message gas system only Heater Fault Message Possible Solutions Page Page AIR Fault Message HI-TEMP Fault Message Possible Solutions Drum Fault Message Page Tumbler Basket Section Electrical Malfunctions Tumbler Basket Section Electrical ComponentsFollowing is for 2-Door Models only Rear Panel Control Problems Probable Causes Possible Solutions Unload 1 Selection Probable Causes PLC OUT PIN 7 = Unload Door Open PLC OUT PIN 10 = Front UPDoor Open Problem Drum Fault Message Malfunction Probable Causes Page Front Door Switch Rear Down Switch LS2Lint Drawer Proximity Switches Base Section Electrical MalfunctionsLint Chamber Pressure Switch PS3 Tumbler Basket Tilt Problems Level FaultProbable Solutions Page Lint Screen Mechanism Problem Screen Fault Lint Chamber Air Pressure Problem AIR Fault Pendant Control Malfunctions Pendant Electrical ComponentsVerify Pendant Electrical Signals Wiring Diagram Temperature Sensing Page Temperature Measurement and Sensing Problems Circuit Wiring to the Analog Input Module MotorsMotor Actuation Problems Probable Causes Motor Protection Device DescriptionsPLC Programmable Logic Controller Error Messages Burner Controller stops heat