American Dryer Corp ADG-464 manual Possible Solutions

Page 70

2a) Burner fan air pressure switch.

3a) Pilot gas valve.

4a) Ignition transformer.

5a) Motorized gas valves.

6a) MS4 AUX.

7a) MS8.

8a) Flame detector and burner chassis ground.

9a) Burner controller.

b)POSSIBLE SOLUTIONS;

1b) Verify that the burner controller module has power. With control voltage “ON,” verify that the burnt fuse L.E.D. indicator of fuse #6 is not “ON.”

If the L.E.D. is “ON” check the fuse.

If the fuse holder L.E.D. is “OFF” verify that MCR (motor control relay) pin #43 has 110 VAC, and that pin #1 of the burner controller is 110 VAC. The indicator light is on the left side of the burner base is the burner controller’s power indicator.

If burner controller module has power, go to paragraph #9b on page 69.

If burner controller module does not have power check circuit wiring and retest.

2b) Burner Fan Air Pressure Switch

This switch must be open prior to a drying cycle, and close during a drying cycle. This feature is required by the burner controller module. Check the function of this switch by measuring for 110 VAC from TB1-23 and TB1-9 on the main electrical panel.

Refer to AD-464 Main Panel Wiring Diagram.

Press the “green” button on the front panel; control voltage “ON.”

Measure for 110 VAC between TB1-23 and 9; it should not be present.

If a voltage is measured check;

Air switch adjustment.

Switch.

Circuitry (AD-464 Main Wiring Diagram and AD-464 Solenoid Junction Box Wiring Diagram).

66

Image 70
Contents ADG-464 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Returning Warranty Cards Parts Returning Warranty Parts Service PartsTroubleshooting TOC Section Safety Precautions What to do if YOU Smell GASPage SPECIFICATIONS/DIMENSIONS SpecificationsDimensions Installation Procedures Reassembly of DryerPage Page Location Requirements Internal AIR, Electric and Water Connections Page Page Page Page Page Left Drum Motor External Supply Connections Page Page Electrical Requirements Electrical RequirementsElectrical Service Specifications PER Dryer Page Fresh AIR Supply Requirements PRE START-UP Preparation for OperationRoutine Maintenance CleaningMonthly Component System Descriptions Page Page Main AIR Blower and Heat Reclaimer System Page Compressed AIR System Additives or SolventsPage Page GAS Burner and Ignition System Switch #1 Recycling Mode Page Page Page Page Page Page Page Safety Devices Level Fault Service PartsWarranty Returning Warranty CardsReturning Warranty Parts Page Troubleshooting Possible Solutions Power MalfunctionsProbable Causes No Control Power Blue Light Off Machine Main Power Shuts Down Blue Indicator Off 2CRB Sprinkler Circuit Description Page If no, go to on Possible Solutions General Description Unless the Water Valve to the Sprinkler is ClosedIntroduction Burner Controller Input Signal ComponentsBurner Ignition Burner Section Input Circuit Component DescriptionLoad Door Switch DS1B Output Signal Component Description Stop Detector Relay Contact SMD noGAS Fault Message gas system only Heater Fault Message Possible Solutions Page Page AIR Fault Message HI-TEMP Fault Message Possible Solutions Drum Fault Message Page Tumbler Basket Section Electrical Malfunctions Tumbler Basket Section Electrical ComponentsFollowing is for 2-Door Models only Rear Panel Control Problems Probable Causes Possible Solutions Unload 1 Selection Probable Causes PLC OUT PIN 7 = Unload Door Open PLC OUT PIN 10 = Front UPDoor Open Problem Drum Fault Message Malfunction Probable Causes Page Lint Drawer Proximity Switches Front Door SwitchRear Down Switch LS2 Base Section Electrical MalfunctionsTumbler Basket Tilt Problems Level Fault Lint Chamber Pressure Switch PS3Probable Solutions Page Lint Screen Mechanism Problem Screen Fault Lint Chamber Air Pressure Problem AIR Fault Pendant Control Malfunctions Pendant Electrical ComponentsVerify Pendant Electrical Signals Wiring Diagram Temperature Sensing Page Temperature Measurement and Sensing Problems Circuit Wiring to the Analog Input Module MotorsMotor Actuation Problems Probable Causes Motor Protection Device DescriptionsPLC Programmable Logic Controller Error Messages Burner Controller stops heat