3.EMERGENCY STOP
If the EMERGENCY STOP
a)PROBABLE CAUSES;
1a) Another EMERGENCY STOP
2a) A Disconnect Plug
3a) Faulty Switch
4a) Wiring Back To TB1
b)POSSIBLE SOLUTIONS;
1b) Verify that ALL other EMERGENCY STOP
2b) Verify that ALL of the Pendant’s disconnect plugs are indeed connected. The disconnect plugs are for removal of the Pendant arm for shipping.
3b With the control voltage off, open pendant assembly and check switch using an OHM meter; replace if defective.
4b) Locate terminal #14 and terminal #15 on TB1 on the bottom of the main electrical enclosure. Open their associated disconnects and place an OHM meter across these terminals. Push the EMERGENCY STOP
•If YES, wiring to TB1 is correct, check wiring on the main electrical panel, then retest.
•If NO, wiring from the pendant to TB1 is incorrect. Check wiring using the appropriated wiring diagrams listed above, and retest.
F.TEMPERATURE SENSING
Introduction
There is one (1) temperature sensing and controlling device in the
90