American Dryer Corp ADG-464 manual AIR Fault Message

Page 73

Check that “NONE” of the thermal and magnetic overloads have “TRIPPED.”

Check circuitry; ADG-464 Main Panel Wiring Diagram

Retest

7b) To verify burner fan motor contactor (MS8) operation:

Apply a 110 VAC voltage to MS8’s terminals A1 and A2 and verify that the contactor activates.

If MS8 cycles this will indicate that its OK. Verify wiring to the device using the ADG-464 Main Panel Wiring Diagram.

If MS8 “DOES NOT” cycle;

Check device and replace if necessary

Retest

8b) Flame Detector & Burner Chassis Ground

To test the flame detector signal refer to Section VI, Part D, Gas Burner and Ignition Systemon page 37 thru page 45.

If the flame detector test fails:

Verify that the flame detector and burner chassis connections, located on the left side if the burner, are sound and tight.

Check wiring (See AD-464 Main Electrical Panel Wiring Diagram and AD-464 Solenoid Junction Box Wiring Diagram).

Retest

9b) To test the burner controller module itself;

Refer to Section VI, Part D, Gas Burner and Ignition System on page 37 thru page 45 for wiring information, concerning the Burner Controller Module (BCM), refer to the ADG-464 Main Panel Wiring Diagram, the ADG-464 Solenoid Junction Box Wiring Diagram, and the ADG-464 Ladder Diagram.

5.“AIR FAULT” Message

PLC (Programmable Logic Controller) MESSAGE “AIR FAULT”

a)PROBABLE CAUSES;

1a) Incorrect Fan (Blower) Rotation.

2a) Lint Chamber Air Pressure Switch.

69

Image 73
Contents ADG-464 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Returning Warranty Cards Parts Returning Warranty Parts Service PartsTroubleshooting TOC Section What to do if YOU Smell GAS Safety PrecautionsPage Specifications SPECIFICATIONS/DIMENSIONSDimensions Reassembly of Dryer Installation ProceduresPage Page Location Requirements Internal AIR, Electric and Water Connections Page Page Page Page Page Left Drum Motor External Supply Connections Page Page Electrical Requirements Electrical RequirementsElectrical Service Specifications PER Dryer Page Fresh AIR Supply Requirements Preparation for Operation PRE START-UPCleaning Routine MaintenanceMonthly Component System Descriptions Page Page Main AIR Blower and Heat Reclaimer System Page Additives or Solvents Compressed AIR SystemPage Page GAS Burner and Ignition System Switch #1 Recycling Mode Page Page Page Page Page Page Page Safety Devices Level Fault Parts ServiceWarranty Returning Warranty CardsReturning Warranty Parts Page Troubleshooting Possible Solutions Power MalfunctionsProbable Causes No Control Power Blue Light Off Machine Main Power Shuts Down Blue Indicator Off 2CRB Sprinkler Circuit Description Page If no, go to on Possible Solutions Unless the Water Valve to the Sprinkler is Closed General DescriptionBurner Ignition Burner Controller Input Signal ComponentsIntroduction Burner Section Input Circuit Component DescriptionLoad Door Switch DS1B Stop Detector Relay Contact SMD no Output Signal Component DescriptionGAS Fault Message gas system only Heater Fault Message Possible Solutions Page Page AIR Fault Message HI-TEMP Fault Message Possible Solutions Drum Fault Message Page Tumbler Basket Section Electrical Components Tumbler Basket Section Electrical MalfunctionsFollowing is for 2-Door Models only Rear Panel Control Problems Probable Causes Possible Solutions PLC OUT PIN 7 = Unload Door Open PLC OUT PIN 10 = Front UP Unload 1 Selection Probable CausesDoor Open Problem Drum Fault Message Malfunction Probable Causes Page Rear Down Switch LS2 Front Door SwitchLint Drawer Proximity Switches Base Section Electrical MalfunctionsTumbler Basket Tilt Problems Level Fault Lint Chamber Pressure Switch PS3Probable Solutions Page Lint Screen Mechanism Problem Screen Fault Lint Chamber Air Pressure Problem AIR Fault Pendant Electrical Components Pendant Control MalfunctionsVerify Pendant Electrical Signals Wiring Diagram Temperature Sensing Page Temperature Measurement and Sensing Problems Motors Circuit Wiring to the Analog Input ModuleMotor Protection Device Descriptions Motor Actuation Problems Probable CausesBurner Controller stops heat PLC Programmable Logic Controller Error Messages