Maytag W10240585B-SP, W10240584B, MGDE200XW Installation Instructions, Venting REQUiREMENTS

Page 10

INSTALLATION INSTRUCTIONS

Venting REQUiREMENTS

WARNING

Fire Hazard

Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent.

Failure to follow these instructions can result in death or fire.

WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.

IMPORTANT: Observe all governing codes and ordinances.

Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or flexible metal vent shall be used for exhausting.

■■ Only a 4" (102 mm) heavy metal exhaust vent and clamps may be used.

■■ Do not use plastic or metal foil vent.

Exhaust hoods:

■■ Must be at least 12" (305 mm) from ground or any object that may obstruct exhaust (such as flowers, rocks, bushes, or snow).

B

 

4"

C

A

(102 mm)

 

 

4"

 

2½"

(102 mm)

 

 

(64 mm)

 

 

4"

 

 

(102 mm)

 

 

Recommended styles:

 

Acceptable styles:

A. Louvered hood

 

C. Angled hood

B. Box hood

 

 

Elbows:

■■ 45° elbows provide better airflow than 90° elbows.

GoodBetter

Rigid metal vent:

■■ Recommended for best drying performance and to prevent crushing and kinking.

Flexible metal vent: (Acceptable only if accessible to clean) ■■ Must be fully extended and supported in final dryer location.

■■ Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance.

■■ Do not install in enclosed walls, ceilings, or floors. ■■ The total length should not exceed 7 3/4 ft. (2.4 m).

NOTE: If using an existing vent system, clean lint from entire length of the system and make sure exhaust hood is not plugged with lint. Replace plastic or metal foil vents with rigid metal or flexible metal vents. Review Vent system chart and if necessary, modify existing vent system to achieve best drying performance.

Clamps:

■■ Use clamps to seal all joints.

■■ Exhaust vent must not be connected or secured with screws or other fastening devices that extend into interior of duct and catch lint. Do not use duct tape.

Improper venting can cause moisture and lint to collect indoors, which may result in:

Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.

Housecleaning problems and health problems.

Vent products can be purchased from your dealer. For more information, see “Assistance or Service” section in your Use and Care Guide.

10

Image 10
Contents Table of Contents Dryer Safety Your safety and the safety of others are very importantWhat to do if YOU Smell GAS Tools needed for all installations Installation Requirements Tools and PartsTools needed for gas installations Parts supplied steam modelsYou will need Dryer DimensionsLocation Requirements Front viewCabinet installation dryer only Closet installation dryer onlyBack view Electric Dryer Power HOOKUP- Canada only Electrical RequirementsGAS Type GAS Dryer Power HookupGAS Supply Requirements Natural GasBurner Input Requirements GAS Supply LineGAS Supply Connection Requirements Dryer GAS PipeInstallation Instructions Venting REQUiREMENTSOptional exhaust installations Alternate exhaust installations for close clearanceChoose your exhaust installation type Plan Vent SystemINStall Vent System Install Leveling LegsMake GAS Connection Connect Inlet HoseAttach long hose to dryer fill valve and tighten coupling Attach long hose to Y connector and tighten couplingsTighten couplings Turn on cold water faucetConnect vent Level dryerTroubleshooting Complete InstallationChecklist Door ReversalSécurité de la sécheuse Votre sécurité et celle des autres est très importanteQUE Faire Dans LE CAS D’UNE Odeur DE GAZ Outils nécessaires pour toutes les installations Exigences Dinstallation Outillage ET PiècesOutils nécessaires aux installations au gaz Pièces fournies tous les modèlesIl vous faudra Exigences DemplacementDimensions DE LA Sécheuse Vue de faceVue arrière Installation dans un placard sécheuse seulement Cest à lutilisateur quincombe la responsabilité de Installation sous comptoir personnalisée sécheuse seulementSpécifications Électriques Toutes les sécheusesConservez CES Instructions Raccordement Dune Sécheuse À GAZInstructions DE Liaison À LA Terre Type DE GAZExigences Concernant LE Raccordement AU GAZ Conversion pour lalimentation au propaneCanalisation DE GAZ Caractéristiques Dalimentation DU BrûleurExigences Concernant Instructions Pour LInstallationLévacuation Planification DU Système Dévacuation Installations dévacuation facultativesDispositions spéciales pour les maisons mobiles Tableau des systèmes dévacuation Installation DU Circuit DévacuationInstaller le clapet dévacuation Raccorder le conduit dévacuation au clapetInstallation DES Pieds DE Nivellement Raccordement AU GAZSerrer les raccords Raccordement DU Tuyau Darrivée DeauFixer le tuyau court et le raccord en Y Fixer le long tuyau au raccord en Y et serrer les raccordsRaccorder le conduit dévacuation à la bouche dévacuation 16. Déplacer la sécheuse à son emplacement finalRaccordement DU Conduit Dévacuation Ouvrir le robinet deau froide17. Régler laplomb de la sécheuse Achever Linstallation Liste DE VérificationRéglage DE Laplomb DE LA Sécheuse Serrer et ajuster les pieds de nivellementDépannage Inversion DE LA PorteW10240584B W10240585B-SP