3-wire connection: Power supply cord
Use where local codes permit connecting
BDE
A
CG F
A.
B.
C.Neutral prong
D.Spade terminals with up turned ends E. ¾" (1.9 cm) UL listed strain relief F. Ring terminals
G.Neutral (white or center wire)
1.Loosen or remove center
2.Connect neutral wire (white or center wire) of power supply cord to the center, silver- colored terminal screw of the terminal block. Tighten screw.
| C |
A |
|
B | D |
| |
| E |
3.Connect the other wires to outer terminal block screws. Tighten screws.
4.Tighten strain relief screws.
5.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold- down screw.
6.You have completed your electrical connection. Now go to “Venting Requirements.”
3-wire connection: Direct wire
Use where local codes permit connecting
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.
Strip 3¹⁄₂" (8.9 cm) of outer covering from end of cable. Strip insulation back 1" (2.5 cm). If using
1" (2.5cm)
3¹⁄₂" (8.9 cm)
When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.
A. External ground conductor screw B. Neutral ground wire
C. Center
E. ³⁄₄" (1.9 cm) UL listed strain relief
1.Loosen or remove center
14