PC Serial Ports

2.For best performance with the PassageWay Service Provider, choose a card that has hardware support for high-speed communications.

The PassageWay Service Provider operates at a data rate of 4800 baud, and it relies on Windows to manage the flow of data through your PC's serial port. Depending upon your configuration, Windows may have problems maintaining high data rates through traditional serial ports. In these situations, a serial port designed for high-speed communications can eliminate such problems while providing a reduced load on the microprocessor (thus increasing the performance of Windows during data transfers relative to standard serial ports). In most cases, the price differential for such a card is quite modest and a worthwhile investment.

Many serial port cards on the market (and most built-in serial ports) use either the 8250 or 16450 Universal Asynchronous Receiver Transmitter (UART) as their key component. Although these UARTs can operate at high speeds, they do not assist the PC's microprocessor in dealing with high-speed data transfer. Under Windows, in particular, data can be lost at high baud rates using these UARTs. If this data loss occurs, the PassageWay Service Provider cannot function properly.

Whenever possible, select a serial port card that uses the 16550 UART. This industry-standard UART is an improved version of the 16450 with hardware support to help offload the microprocessor during high-speed data transfers. Windows 3.1 has built-in support for the 16550, so no special software configuration is required to obtain the benefits of the 16550's enhanced capabilities. In addition, any high-speed peripheral can benefit from the 16550 (for example, a 9.6-Kbps or 14.4-Kbps data and/or fax modem), not only the PassageWay Service Provider.

In general, since there is no way of knowing ahead of time if your particular PC configuration requires an enhanced serial port for the PassageWay Service Provider, Lucent strongly recommends that you purchase a card based on the 16550 UART to insure trouble-free operation with the PassageWay Service Provider.

A-11

Image 94
Contents Getting Started Your Responsibility for Your Systems Security WWW Home Contents Using Partner Extension Programming Index Figures What is the PassageWay Service Provider? IntroductionPartner Extension Programming ConnectAbout This Guide Page User Responsibilities Conventions Used in This GuideGetting Help Installing and Configuring PassageWay Service2 Provider OverviewNew PassageWay Service Provider Users Installing and Configuring the PassageWay Service Provider PassageWay Service Provider Components Components of the PassageWay Adapter PassageWay Service Provider Requirements Page  Partner ACS Before You Begin Installing the PassageWay Adapter Connecting the Line Cord to the PassageWay Adapter Connecting the Modular Phone Cord to the PassageWay Adapter Page Installing the Software Page Page Page Find PassageWay Link Dialog Box Page Sample PassageWay Configurator COM Port Dialog Box Partner System Version Dialog Box Telephone Models Dialog Box Extension Number Dialog Box Sample Phone Line Information Dialog Box Choose Outside Line 10. Sample Feature Buttons Dialog Box Page Page Page Page Removing the PassageWay Service Provider Select UnInstaller for Service ProviderPage Installing and Configuring the PassageWay Service Provider Page Using Partner Extension Programming What is Partner Extension Programming? What is Partner Extension Programming? Page Page Page System Administration Capabilities Helpful Hints Running Partner Extension Programming PassageWay for PartnerPartner Extension Programming Message Box Sample Reading Telephone Status Box Sample Partner Extension Programming File Troubleshooting General Troubleshooting PassageWay for Partner Troubleshooting Problem 6 You cannot make a call with the speakerphone Troubleshooting Troubleshooting Troubleshooting Troubleshooting Problem 18 You receive an error when you shut down Windows Problem 17 The PassageWay Link is not always detectedProblem 19 Your COM serial port is not recognized Troubleshooting Problem 24 a message box appears displaying the message Problem 27 a message box appears displaying the message Problem 25 a message box appears displaying the messageProblem 26 a message box appears displaying the message Problem 28 a message box appears displaying the messageProblem 30 a message box appears displaying the message Problem 31 a message box appears displaying the messageProblem 1 The LED is off PassageWay Adapter LEDTroubleshooting Partner Extension Programming Feature X with feature Y failed… Problem 4 Partner Extension Programming does not run Troubleshooting Connect Problem 1 Connect displays the message This applicationTroubleshooting Failure Code Failure Code -134 or Failure Code -131, -132, -133, orFailure Code -200 and above Troubleshooting Then terminates PC Serial Ports Background IRQ Mechanism Page IRQ Serial Ports Under Windows Workarounds and Solutions to IRQ Conflict Problem Page Page Selecting an Add-On Serial Port Card Page Index IN-2