Vector VEC051D owner manual Introduction, Controls and Functions, Maxx SST Features

Page 4

90548013 VEC051D INVERTER.qxp 3/6/09 10:31 AM Page 3

THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS FOR THE MAXX SSTTM COMPACT POWER INVERTER MODEL VEC051D.

WARNING: TO REDUCE THE RISK OF INJURY:

Follow these instructions and those published by battery manufacturer and the manufacturer of any equipment you intend to use with this unit. Review cautionary markings on these products and on engine.

INTRODUCTION

Thank you for purchasing the VEC051D MAXX SSTTM Compact Power Inverter. Please read this Instruction Manual carefully before use to ensure optimum performance and to avoid damage to this product.

This Power Inverter is configured with the latest Soft Start Technology (SST) and supplies continuous power and peak watts in the form of 120 volt AC outlets to run most household or electronic appliances. Before introduction of SST, high start-up currents from large inductive loads could shut down an inverter. SST improves inverter operation by:

Gradual voltage ramp-up during inverter start-up, eliminating failed cold starts under load.

Output that momentarily dips in voltage and quickly recovers to allow large motorized loads to start, eliminating most shutdowns from momentary overloads.

Soft Start Technology, dramatically increases reliability and life of the product.

Added features include automatic shutdown and a low battery alarm to prevent damage to your battery.

FEATURES

On the front panel are two LED indicators. The green LED indicates power and proper operation of the inverter; the red LED indicates inverter shutdown from over-load or over-temperature condition, or abnormal input voltages. The ON/OFF Switch turns the inverter ON and OFF. The switch can also be used to force reset of inverter circuits by switching it OFF, then back ON again. All models also feature a port to attach a remote control (sold separately).

120 volt AC power is supplied through four North American three-prong type outlets. The outlets can accommodate either two- or three-pin AC plugs.

Controls and Functions

Front View Diagram

 

 

Back View Diagram

 

GREEN POWER LED

RED FAULT

ON/OFF

 

 

 

INDICATOR

LED INDICATOR

 

 

POWER

 

 

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GROUNDING

HIGH-SPEED

POSITIVE (+)

 

 

 

 

TERMINAL

COOLING FANS

TERMINALS

 

 

 

 

NEGATIVE (–)

 

WATTAGE

(4) 120 VOLT

PORT FOR

 

TERMINALS

 

POWER METER

REMOTE CONTROL

 

AC OUTLETS

 

 

 

 

(SOLD SEPARATELY)

 

 

 

 

 

 

 

 

Maxx SST™ Features

Built-in Automatic Features include:

Overload and over-temperature shutdown activated if AC output exceeds rated watts

AC short-circuit shutdown

Low voltage audible alarm (sounds at 10.5 volts input)

Low-voltage shutdown (activates at 10.0 volts DC)

High-input voltage shutdown (activates at above 15.5 volts DC)

MAXX SST™ uses a 12 volt DC power source like those found in motor vehicles, or it can be operated using multiple battery configurations with commercial battery chargers or solar battery chargers. For most heavy-duty applications, a multiple battery configuration and the use of deep-cycle batteries is required.

When using multiple batteries, inverters can be operated from one of the vehicle 12 volt batteries, so there’s always one battery with adequate charge to start an engine.

MAXX SST™ includes a high-surge capability. This is required to start heavy loads, such as motors and other inductive devices.

3

Image 4 Contents
Maxx Ssttm VEC051DSafety Guidelines / Definitions Volts Minimum Gage for Cord SetsImportant Safety Instructions Important Cable InformationFeatures Maxx SST FeaturesFront View Diagram Back View Diagram IntroductionAppliance Power Consumption Power Inverter Output WaveformPrinciple of Operation Appliance Consumption in Amps and Watts Chart Appliance AMPS@ WATTS@120VAC 880Power Source Requirements Determining Battery SizeOperating Instructions RuntimeInstallation Protective FeaturesBattery Operating Times Temporary Installation Installation ProceduresOperating Environment Permanent Installation #2AWG power source cables must not exceed 6 feet in lengthConnection To Load Operating TipsCommon Audio/Visual Problems TroubleshootingProblem Solution Fault Protection and Troubleshooting Guide Resetting the UnitCare and Maintenance Fuse Replacement Preventive MaintenanceAccessories SpecificationsYear Limited Warranty Program Compact DE 3000 W Lignes Directrices EN Matière DE SÉCURITÉ/DÉFINITIONS Directives DE Sécurité Importantes Avertissement Pour Réduire LE Risque D’INCENDIEConserver CES Directives CaractéristiquesRenseignements Importants SUR LE Câble Avertissement Pour Réduire LE Risque DE BlessuresCommandes et fonctions Caractéristiques du Maxx SSTPrincipe DE Fonctionnement Forme d’onde de sortie du convertisseur continu-alternatifConsommation Énergétique DES Appareils Électriques Produits incompatiblesPuissance À Appareil120 V C.A Fonctionnement Exigences relatives à la source d’alimentationDétermination de la taille de la batterie Durée de fonctionnementCaractéristiques de sécurité Durées de fonctionnement des batteriesInstallation temporaire Mode d’installationEnvironnement d’exploitation Installation permanente Connexion à la charge Conseils d’utilisationProblème Solution DépannageProblèmes audiovisuels communs Guide de protection contre les défaillances et de dépannageRemplacement de fusible AccessoiresRéenclenchement des circuits de l’appareil RangementLa liberté de la Puissance Programme DE Garantie Restreinte DE Deux ANSCordless,MAXXRechargeableSST Normas DE SEGURIDAD/DEFINICIONES Instrucciones Importantes Sobre Seguridad Advertencia Para Reducir EL Riesgo DE Descarga EléctricaAdvertencia Para Reducir EL Riesgo DE Incendio Información Importante Sobre LOS CablesConserve Estas Instrucciones IntroducciónCaracterísticas Controles y funcionesCaracterísticas de Maxx SST Principio DE OperaciónLa forma de onda de salida del conversor eléctrico Comparación de onda senoidal modificada y onda senoidalConsumo DE Energía DE LOS Artefactos ATENCIÓN. Para Reducir EL Riesgo DE Daños a LA PropiedadCuadro DEL Consumo EN Amperios Y Vatios DE Artefactos Instrucciones DE OperaciónRequisitos de la fuente de energía ArtefactoCómo determinar el tamaño de la batería Tiempo de funcionamientoInstalación Características de protecciónTiempos de funcionamiento de la batería Procedimientos de instalación Entorno de operaciónInstalación temporaria Diagrama de configuración de baterías permanentes Instalación permanenteSugerencias de operación Conexión a la cargaNota sobre el uso del control remoto se vende por separado Detección DE Problemas Problemas visuales/de audio frecuentesGuía de protección de fallas y detección de problemas Problema SoluciónReinicio de la unidad AlmacenamientoReemplazo de fusibles Mantenimiento preventivoLa libertad de la Energía Cat No. VEC051D Form No March
Related manuals
Manual 2 pages 33.99 Kb Manual 44 pages 30.16 Kb