3.4.7 Heat insulation

CAUTION!

The area above the converter support must not be heat-insulated.

The heat insulation 3 may only extend to the maximum height 1 shown below up to the connecting screws of the measuring sensor.

Figure 3-7: Heat insulation on connection piece and signal cable

1Max. height of insulation up to intermediate piece between measuring sensor and signal converter

2Max. thickness of the insulation up to the bend of the pressure pipe

3Insulation

CAUTION!

The heat insulation 3 may only extend as far as the bend of the pressure sensing line 2.

06/2009 - SFIDK.PS.050.F2.02 A5E02100423

www.siemens.com/flow

25

Image 25
Contents Page Imprint Contents Contents Technical data Intended use Safety InstructionsDevices are particularly suitable for the measurement Devices are rated for the following flow velocitiesCE marking CertificationsCopyright and data protection Safety instructions from the manufacturerDisclaimer Information concerning the documentation Product liability and warrantySafety warnings are indicated by the following symbols Safety instructions for the operatorInstrument versions Scope of deliveryDevices come in the following versions Following designs are available as optionsSandwich version Devices with connection flangeFree air delivery measurement FAD optional Gross heat meter Dual seal Nameplate Transport StorageInstallation condtitions InstallationMeasurement of liquids Prohibited installationRecommended installations for measurement of liquids Measurement of vapours and gases Prohibited installationPreferred mounting position Pipelines with control valvePreferred mounting position Allen screws on connection housing Turning the connection housingTurn the display as follows Turning the displayHeat insulation Minimum inlet runs Inlet and outlet runsFlow straightener Minimum outlet runsGeneral installation notes InstallationInstalling devices in flange design Installing devices in sandwich design Electrical Connections Safety instructionsElectrical Connections Following procedures are to be performedMaximum load resistance is calculated as follows Electrical connection of current and pulse outputTotalizer / pulse output Power supplyMaximum frequency of the pulse output is fmax = 0.5 Hz Electrical ConnectionsGrounding connections Therefore it is essential to observe the following points Protection categoryStart START-UPStart-up and control Display and operating elements OperationOperation Switch from measuring mode to menu modeOperating principles Functional description of the keysNavigation within the menu structure Changing the settings in the menuChanging units Totalizer / pulse output Measures in the event of faulty indicationsMax. pulses per hour ExampleOverview of the most important functions and units Volume Standard volume Mass Liquids, steams, gases Air GasLevel Designation Explanation Temp Absolute Power Energy Density Pressure Over Volume Standard volume Mass Liquids, steams, gases GasError message Cause Measure Error messagesOverview of firmware versions Menu structureCharacter selection in change mode Entering values in change modeMenu item Quick Setup Level Designation Selection / entry Explanation Menu item TestsTest current is maintained until the menu has been exited Menu item Setup firmware version basic Hart SV Operation Menu item Setup firmware version steam Reset heat energy Hart tertiary variable Temp. ↑ Pressure ↑ Density Operation Menu item Setup firmware version gas Hart SV RPM Pressure, temperature and density Operation Following steps are to be performed Replacing signal converter / LCD displayAvailability of services ServiceSpare parts availability Returning the device to the manufacturerForm for copying to accompany a returned device Functional principle Technical DataMeasuring system Technical dataMeasuring accuracy Operating conditions Installation conditionsMaterials Electrical connections Process connectionsApprovals and certifications Flange versions Dimensions and weightsFlange version EN Technical Data NPS Flange version Asme B16.5Sandwich version EN Sandwich version Asme Size Pressure Dimensions inches Weight lbs RatingWith Without Pressure sensor Measuring ranges Flow tablesWater AirProduct Nominal sizes Minimum flow rates Maximum flow rates Flow rate limitsFt/s Measuring range saturated steam 10.5...20 bar Measuring range saturated steam 1...7 barKg/h 1092-1Measuring range saturated steam 150...300 psig Measuring range saturated steam 15...100 psigLbs/h Sitrans FX300