8 TECHNICAL DATA

8.3 Dimensions and weights

8.3.1 Flange versions

SITRANS FX300

Option: version with 2 transmitters

a = 133 mm / 5.24"

b = 105 mm / 4.13"

Dimension H x 2

c = 179 mm / 7.05"

Specified weight + 2.80 kg

Flange version EN 1092-1

Size

Pressure

 

Dimensions [mm]

 

 

Weight [kg]

 

rating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DN

PN

d

D

L

 

H

l

With

Without

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pressure sensor

 

 

 

 

 

 

 

 

 

 

15

40

17.3

95

200

 

265

174.3

6.1

5.5

 

 

 

 

 

 

 

 

 

 

15

100

17.3

105

200

 

265

174.3

7.1

6.5

 

 

 

 

 

 

 

 

 

 

25

40

28.5

115

200

 

265

174.3

7.9

7.3

 

 

 

 

 

 

 

 

 

 

25

100

28.5

140

200

 

265

174.3

9.9

9.3

 

 

 

 

 

 

 

 

 

 

40

40

43.1

150

200

 

270

174.5

10.8

10.2

 

 

 

 

 

 

 

 

 

 

40

100

42.5

170

200

 

270

174.5

14.8

14.2

 

 

 

 

 

 

 

 

 

 

50

16

54.5

165

200

 

275

174.5

12.7

12.1

 

 

 

 

 

 

 

 

 

 

50

40

54.5

165

200

 

275

174.5

12.9

12.3

 

 

 

 

 

 

 

 

 

 

50

63

54.5

180

200

 

275

174.5

16.9

16.3

 

 

 

 

 

 

 

 

 

 

50

100

53.9

195

200

 

275

174.5

18.4

17.8

 

 

 

 

 

 

 

 

 

 

80

16

82.5

200

200

 

290

174.25

17.4

16.8

 

 

 

 

 

 

 

 

 

 

80

40

82.5

200

200

 

290

174.25

19.4

18.8

 

 

 

 

 

 

 

 

 

 

80

63

81.7

215

200

 

290

174.25

23.4

22.8

 

 

 

 

 

 

 

 

 

 

80

100

80.9

230

200

 

290

174.25

27.4

26.8

 

 

 

 

 

 

 

 

 

 

100

16

107.1

220

250

 

310

174.5

22

21.4

 

 

 

 

 

 

 

 

 

 

100

40

107.1

235

250

 

310

174.5

25

24.4

 

 

 

 

 

 

 

 

 

 

100

63

106.3

250

250

 

310

174.5

30

29.4

 

 

 

 

 

 

 

 

 

 

70

www.siemens.com/flow

06/2009 - SFIDK.PS.050.F2.02 A5E02100423

Image 70
Contents Page Imprint Contents Contents Technical data Devices are particularly suitable for the measurement Safety InstructionsIntended use Devices are rated for the following flow velocitiesCertifications CE markingCopyright and data protection Safety instructions from the manufacturerDisclaimer Product liability and warranty Information concerning the documentationSafety instructions for the operator Safety warnings are indicated by the following symbolsDevices come in the following versions Scope of deliveryInstrument versions Following designs are available as optionsDevices with connection flange Sandwich versionFree air delivery measurement FAD optional Gross heat meter Dual seal Nameplate Storage TransportInstallation Installation condtitionsProhibited installation Measurement of liquidsRecommended installations for measurement of liquids Prohibited installation Measurement of vapours and gasesPreferred mounting position Pipelines with control valvePreferred mounting position Turning the connection housing Allen screws on connection housingTurning the display Turn the display as followsHeat insulation Inlet and outlet runs Minimum inlet runsMinimum outlet runs Flow straightenerInstallation General installation notesInstalling devices in flange design Installing devices in sandwich design Safety instructions Electrical ConnectionsFollowing procedures are to be performed Electrical ConnectionsElectrical connection of current and pulse output Maximum load resistance is calculated as followsPower supply Totalizer / pulse outputElectrical Connections Maximum frequency of the pulse output is fmax = 0.5 HzGrounding connections Protection category Therefore it is essential to observe the following pointsStart START-UPStart-up and control Operation Display and operating elementsOperating principles Switch from measuring mode to menu modeOperation Functional description of the keysChanging the settings in the menu Navigation within the menu structureChanging units Max. pulses per hour Measures in the event of faulty indicationsTotalizer / pulse output ExampleOverview of the most important functions and units Volume Standard volume Mass Liquids, steams, gases Air GasLevel Designation Explanation Volume Standard volume Mass Liquids, steams, gases Gas Temp Absolute Power Energy Density Pressure OverError messages Error message Cause MeasureMenu structure Overview of firmware versionsEntering values in change mode Character selection in change modeMenu item Quick Setup Level Designation Selection / entry Explanation Menu item TestsTest current is maintained until the menu has been exited Menu item Setup firmware version basic Hart SV Operation Menu item Setup firmware version steam Reset heat energy Hart tertiary variable Temp. ↑ Pressure ↑ Density Operation Menu item Setup firmware version gas Hart SV RPM Pressure, temperature and density Operation Replacing signal converter / LCD display Following steps are to be performedSpare parts availability ServiceAvailability of services Returning the device to the manufacturerForm for copying to accompany a returned device Technical Data Functional principleMeasuring system Technical dataMeasuring accuracy Operating conditions Installation conditionsMaterials Electrical connections Process connectionsApprovals and certifications Flange versions Dimensions and weightsFlange version EN Technical Data Flange version Asme B16.5 NPSSandwich version EN Sandwich version Asme Size Pressure Dimensions inches Weight lbs RatingWith Without Pressure sensor Water Flow tablesMeasuring ranges AirProduct Nominal sizes Minimum flow rates Maximum flow rates Flow rate limitsFt/s Kg/h Measuring range saturated steam 1...7 barMeasuring range saturated steam 10.5...20 bar 1092-1Measuring range saturated steam 150...300 psig Measuring range saturated steam 15...100 psigLbs/h Sitrans FX300