Siemens FX300 manual Contents

Page 4

CONTENTS

 

 

SITRANS FX300

 

 

 

 

4 Electrical connections

31

4.1

Safety instructions

31

4.2

Connecting the signal converter

32

4.3

Electrical connection of current and pulse output

33

4.3.1 Power supply

34

4.3.2 Totalizer / pulse output

34

4.4

Grounding connections

36

4.5

Protection category

37

5 Start-up

38

5.1

Start

38

5.2

Start-up and control

38

6 Operation

39

6.1

Display and operating elements

39

6.2

Operating principles

40

6.2.1 Functional description of the keys

40

6.2.2 Switch from measuring mode to menu mode

40

6.2.3 Navigation within the menu structure

41

6.2.4 Changing the settings in the menu

41

6.2.5 Changing units

42

6.2.6 Measures in the event of faulty indications

43

6.3

Overview of the most important functions and units

44

6.4

Error messages

46

6.5

Menu structure

47

6.5.1 Overview of firmware versions

47

6.5.2 Entering values in change mode

48

6.5.3 Character selection in change mode

48

6.5.4 Menu item Quick Setup

49

6.5.5 Menu item Tests

50

6.5.6 Menu item Setup (firmware version - basic)

51

6.5.7 Menu item Setup (firmware version - steam)

54

6.5.8 Menu item Setup (firmware version - gas)

58

7 Service

63

7.1

Replacing signal converter / LCD display

63

7.2

Spare parts availability

64

7.3

Availability of services

64

7.4

Returning the device to the manufacturer

64

7.4.1 General information

64

7.4.2 Form (for copying) to accompany a returned device

65

4

www.siemens.com/flow

06/2009 - SFIDK.PS.050.F2.02 A5E02100423

Image 4
Contents Page Imprint Contents Contents Technical data Safety Instructions Intended useDevices are particularly suitable for the measurement Devices are rated for the following flow velocitiesCertifications CE markingCopyright and data protection Safety instructions from the manufacturerDisclaimer Product liability and warranty Information concerning the documentationSafety instructions for the operator Safety warnings are indicated by the following symbolsScope of delivery Instrument versionsDevices come in the following versions Following designs are available as optionsDevices with connection flange Sandwich versionFree air delivery measurement FAD optional Gross heat meter Dual seal Nameplate Storage TransportInstallation Installation condtitionsProhibited installation Measurement of liquidsRecommended installations for measurement of liquids Prohibited installation Measurement of vapours and gasesPreferred mounting position Pipelines with control valvePreferred mounting position Turning the connection housing Allen screws on connection housingTurning the display Turn the display as followsHeat insulation Inlet and outlet runs Minimum inlet runsMinimum outlet runs Flow straightenerInstallation General installation notesInstalling devices in flange design Installing devices in sandwich design Safety instructions Electrical ConnectionsFollowing procedures are to be performed Electrical ConnectionsElectrical connection of current and pulse output Maximum load resistance is calculated as followsPower supply Totalizer / pulse outputElectrical Connections Maximum frequency of the pulse output is fmax = 0.5 HzGrounding connections Protection category Therefore it is essential to observe the following pointsStart START-UPStart-up and control Operation Display and operating elementsSwitch from measuring mode to menu mode OperationOperating principles Functional description of the keysChanging the settings in the menu Navigation within the menu structureChanging units Measures in the event of faulty indications Totalizer / pulse outputMax. pulses per hour ExampleOverview of the most important functions and units Volume Standard volume Mass Liquids, steams, gases Air GasLevel Designation Explanation Volume Standard volume Mass Liquids, steams, gases Gas Temp Absolute Power Energy Density Pressure OverError messages Error message Cause MeasureMenu structure Overview of firmware versionsEntering values in change mode Character selection in change modeMenu item Quick Setup Level Designation Selection / entry Explanation Menu item TestsTest current is maintained until the menu has been exited Menu item Setup firmware version basic Hart SV Operation Menu item Setup firmware version steam Reset heat energy Hart tertiary variable Temp. ↑ Pressure ↑ Density Operation Menu item Setup firmware version gas Hart SV RPM Pressure, temperature and density Operation Replacing signal converter / LCD display Following steps are to be performedService Availability of servicesSpare parts availability Returning the device to the manufacturerForm for copying to accompany a returned device Technical Data Functional principleMeasuring system Technical dataMeasuring accuracy Operating conditions Installation conditionsMaterials Electrical connections Process connectionsApprovals and certifications Flange versions Dimensions and weightsFlange version EN Technical Data Flange version Asme B16.5 NPSSandwich version EN Sandwich version Asme Size Pressure Dimensions inches Weight lbs RatingWith Without Pressure sensor Flow tables Measuring rangesWater AirProduct Nominal sizes Minimum flow rates Maximum flow rates Flow rate limitsFt/s Measuring range saturated steam 1...7 bar Measuring range saturated steam 10.5...20 barKg/h 1092-1Measuring range saturated steam 150...300 psig Measuring range saturated steam 15...100 psigLbs/h Sitrans FX300