Siemens FX300 manual Installation condtitions

Page 18

3 INSTALLATION

 

 

SITRANS FX300

 

 

 

 

3.4 Installation condtitions

INFORMATION!

For accurate volumetric flow measurement the measuring device needs a completely filled pipe and a fully developed flow profile.

Please observe the instructions regarding inlet and outlet pipe runs as well as the installation position.

In the event of vibrations on the piping, select the installation site so that the vibrations are at their lowest in a transverse direction to the flowmeter.

CAUTION!

When installing the device in the piping, the following points must be observed:

Nominal diameter of connection pipe flange = nominal flange diameter of pipe!

Use flanges with smooth holes, e.g. welding neck flanges.

Align carefully the holes of the connecting flange and the flowmeter flange.

Check the compatibility of the gasket material with the process product.

Make sure that the gaskets are arranged concentrically. The flange gaskets must not project into the pipe cross-section.

The flanges have to be concentric.

There must not be any pipe bends, valves, flaps or other internals in the immediate inlet run.

Devices in sandwich version may only be installed using a centering ring.

Never install the device directly behind piston compressors or rotary piston meters.

Do not lay signal cables directly next to cables for the power supply.

18

www.siemens.com/flow

06/2009 - SFIDK.PS.050.F2.02 A5E02100423

Image 18
Contents Page Imprint Contents Contents Technical data Devices are particularly suitable for the measurement Safety InstructionsIntended use Devices are rated for the following flow velocitiesCertifications CE markingSafety instructions from the manufacturer Copyright and data protectionDisclaimer Product liability and warranty Information concerning the documentationSafety instructions for the operator Safety warnings are indicated by the following symbolsDevices come in the following versions Scope of deliveryInstrument versions Following designs are available as optionsDevices with connection flange Sandwich versionFree air delivery measurement FAD optional Gross heat meter Dual seal Nameplate Storage TransportInstallation Installation condtitionsProhibited installation Measurement of liquidsRecommended installations for measurement of liquids Prohibited installation Measurement of vapours and gasesPipelines with control valve Preferred mounting positionPreferred mounting position Turning the connection housing Allen screws on connection housingTurning the display Turn the display as followsHeat insulation Inlet and outlet runs Minimum inlet runsMinimum outlet runs Flow straightenerInstallation General installation notesInstalling devices in flange design Installing devices in sandwich design Safety instructions Electrical ConnectionsFollowing procedures are to be performed Electrical ConnectionsElectrical connection of current and pulse output Maximum load resistance is calculated as followsPower supply Totalizer / pulse outputElectrical Connections Maximum frequency of the pulse output is fmax = 0.5 HzGrounding connections Protection category Therefore it is essential to observe the following pointsSTART-UP StartStart-up and control Operation Display and operating elementsOperating principles Switch from measuring mode to menu modeOperation Functional description of the keysChanging the settings in the menu Navigation within the menu structureChanging units Max. pulses per hour Measures in the event of faulty indicationsTotalizer / pulse output ExampleVolume Standard volume Mass Liquids, steams, gases Air Gas Overview of the most important functions and unitsLevel Designation Explanation Volume Standard volume Mass Liquids, steams, gases Gas Temp Absolute Power Energy Density Pressure OverError messages Error message Cause MeasureMenu structure Overview of firmware versionsEntering values in change mode Character selection in change modeMenu item Quick Setup Menu item Tests Level Designation Selection / entry ExplanationTest current is maintained until the menu has been exited Menu item Setup firmware version basic Hart SV Operation Menu item Setup firmware version steam Reset heat energy Hart tertiary variable Temp. ↑ Pressure ↑ Density Operation Menu item Setup firmware version gas Hart SV RPM Pressure, temperature and density Operation Replacing signal converter / LCD display Following steps are to be performedSpare parts availability ServiceAvailability of services Returning the device to the manufacturerForm for copying to accompany a returned device Technical Data Functional principleTechnical data Measuring systemMeasuring accuracy Installation conditions Operating conditionsMaterials Process connections Electrical connectionsApprovals and certifications Dimensions and weights Flange versionsFlange version EN Technical Data Flange version Asme B16.5 NPSSandwich version EN Size Pressure Dimensions inches Weight lbs Rating Sandwich version AsmeWith Without Pressure sensor Water Flow tablesMeasuring ranges AirFlow rate limits Product Nominal sizes Minimum flow rates Maximum flow ratesFt/s Kg/h Measuring range saturated steam 1...7 barMeasuring range saturated steam 10.5...20 bar 1092-1Measuring range saturated steam 15...100 psig Measuring range saturated steam 150...300 psigLbs/h Sitrans FX300