| OPERATION 6 |
| SITRANS FX300 |
|
| ||
| 6.5.4 Menu item Quick Setup |
|
|
| |
|
|
|
| ||
|
|
|
|
| |
| Level | Designation | Selection / entry field | Explanation | |
|
|
|
|
| |
| 1.1.1 | Language |
| Select menu language | |
|
| → |
|
|
|
|
| German ↑... | German language | ||
|
|
| |||
|
|
|
|
| |
|
|
| French ↑… | French language | |
|
|
|
|
| |
|
|
| English ↑...^ | English language | |
|
|
|
|
| |
| 1.1.2 | Location | 0000000000 | Enter the name of the location (max. | |
|
| → | Location↑…↑...↑...^ | 10 characters) | |
| 1.1.3 | Maes.Inst |
| Select type of flow measurement | |
|
| → |
|
|
|
|
| Volume ↑… | Volume measurement | ||
|
|
| |||
|
|
|
|
| |
|
|
| Norm. Vol. ↑… 1 | Standard volume flow measurement | |
|
|
|
|
| |
|
|
| Mass ↑...^ | Mass flow measurement | |
|
|
|
|
| |
| 1.1.4 | Max. Flow |
| Set maximum flow rate | |
|
| → |
|
|
|
|
|
|
|
| |
|
| 2 | m3/h | Select unit for volume flow | |
|
|
| Unit ↑...^ | measurement | |
|
|
|
|
|
|
|
|
| 888888888 |
|
|
|
|
| Upp.Limit |
|
|
|
|
|
|
| |
|
|
| 00600.0000 or other value | Enter value for the maximum volume | |
|
|
| m3/h ↑…↑...↑...^ | flow | |
|
|
| Display Unit / | Display flow rate in units / | |
|
|
| Display %Max Flow ↑...^ | in % of maximum flow rate | |
|
|
|
|
| |
|
| 3 | m3/h norm | Select unit for standard volume flow | |
|
|
| Unit ↑...^ | measurement | |
|
|
|
|
| |
|
|
| 00600.0000 or other value | Enter value for the maximum | |
|
|
| m3/h norm ↑…↑...↑...^ | standard volume flow rate | |
|
|
| Display Unit / | Display flow rate in units / | |
|
|
| Display %Max Flow ↑...^ | in % of maximum flow rate | |
|
|
|
|
| |
|
| 4 | kg/h | Select unit for mass flow | |
|
|
| Unit | measurement | |
|
|
|
|
| |
|
|
| 00600.0000 or other value | Enter value for the maximum mass | |
|
|
| kg/h ↑…↑...↑...^ | flow rate | |
|
|
| Display Unit / | Display flow rate in units / | |
|
|
| Display %Max Flow ↑...^ | in % of maximum flow rate | |
|
|
|
|
|
|
| 1.1.5 | Min. Flow | 001111111 |
|
|
|
| → |
|
|
|
|
| 00300.0000 | The minimum flow rate value is | ||
|
|
| |||
|
|
| m3/h ^ | ||
| 1.1.6 | Timeconst. | 00002.0000 | Enter the time constant for the | |
|
| → | s ↑…↑...↑...^ | measured value output in seconds | |
|
|
|
| (0 – 20 s) | |
|
|
|
| 0: disabled | |
|
|
|
|
|
|
1only with gas
2available if Maes.Inst = Volume (see menu item 1.1.3)
3available if Maes.Inst = Norm. Vol. (see menu item 1.1.3)
4available if Maes.Inst = Mass (see menu item 1.1.3)
06/2009 - SFIDK.PS.050.F2.02 A5E02100423 | www.siemens.com/flow | 49 |