6 OPERATION

 

 

 

 

 

 

 

 

 

 

 

SITRANS FX300

 

 

 

 

 

 

 

 

 

 

 

 

Level

Designation

Selection / entry

Explanation

 

 

 

 

 

 

 

 

 

3.4.2

Medium

 

 

 

Set process medium

 

 

 

(available if Fluid = Gas /

 

 

 

 

 

 

 

Air ...

 

Air

 

 

 

Wet Gas, see menu item

 

 

 

3.4.1)

 

Ammonia ...

Ammonia ...

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Argon ...

 

Argon

 

 

 

 

 

 

 

 

 

 

 

 

etc.

...^

other gases not listed here

 

 

 

 

 

 

 

 

 

3.4.3

% Gas

 

 

 

Determine composition of gas mixture

 

 

 

(available if Fluid = Gas

 

 

 

 

 

 

 

050.000000

 

Select gas and enter percentage

 

 

 

Mix., see menu item 3.4.1)

 

 

 

Air ......^

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100.00

 

Total percentage

 

 

 

 

 

Total % ^

 

 

 

 

 

 

 

 

 

 

3.4.4

%Rel.Hum .

0000000.00

...

Determine relative humidity

 

 

 

(available if Fluid = Wet

% Rel.Hum

 

 

 

 

Gas, see menu item 3.4.1)

...^

 

 

 

 

 

 

 

 

 

 

 

3.4.6

FAD Unit.

 

 

 

Determine unit for FAD

 

 

 

(available if Meter Type =

 

 

 

 

 

 

 

FAD m3/h

 

Set unit for FAD

 

 

 

FAD meter, see menu

 

 

 

item 5.4.1, service

Unit

...^

 

 

 

 

personnel only)

 

 

 

 

 

 

 

Disp. on /

 

Display measured value /

 

 

 

 

 

 

 

 

 

 

Disp. off ...^

Do not display measured value

 

 

 

 

 

 

 

 

3.4.7

Suct.Temp.

 

 

 

Enter temperature in suction area of compressor

 

 

 

(available if Meter Type =

 

 

 

 

 

 

 

°C

 

 

Select temperature unit

 

 

 

FAD meter, see menu

...^

 

 

 

item 5.4.1, service

Unit

 

 

 

 

 

personnel only)

0000200.00

 

Enter temperature value

 

 

 

 

 

°C ......^

 

 

 

3.4.8

Atm.Press.

 

 

 

Atmospheric pressure

 

 

 

(available if Meter Type =

 

 

 

 

 

 

 

Pa

 

 

Select pressure unit

 

 

 

FAD meter, see menu

...^

 

 

Unit

 

 

 

 

item 5.4.1, service

 

 

 

 

personnel only)

00001.0000

 

Enter pressure value

 

 

 

 

 

Pa ......^

 

 

 

3.4.9

Fil. P. Drop.

 

 

 

Pressure drop via filter at compressor inlet

 

 

 

(available if Meter Type =

 

 

 

 

 

 

 

Pa

 

 

Select pressure unit

 

 

 

FAD meter, see menu

 

 

 

 

Unit ...^

 

 

 

 

 

item 5.4.1, service

 

 

 

 

 

personnel only)

00000.0000

 

Enter pressure value

 

 

 

 

 

Pa ......^

 

 

 

3.4.10

Inlet RH

0000060.00

...

Enter relative humidity in suction area of compressor

 

 

 

(available if Meter Type =

% Rel.Hum

 

 

 

 

FAD meter, see menu

...^

 

 

 

 

 

item 5.4.1, service

 

 

 

 

 

 

 

personnel only)

 

 

 

 

 

 

3.4.11

Actual Rpm

0001500.00

 

Current speed of compressor motor in revolutions per

 

 

 

(available if Meter Type =

RPM ^

 

minute

 

 

FAD meter, see menu

 

 

 

 

 

 

 

item 5.3.1, service

 

 

 

 

 

 

 

personnel only)

 

 

 

 

 

 

3.4.12

Rated Rpm.

0001500.00

 

Rated speed of compressor motor in revolutions per

 

 

 

(available if Meter Type =

RPM ^

 

minute

 

 

FAD meter, see menu

 

 

 

 

 

 

 

item 5.4.1, service

 

 

 

 

 

 

 

personnel only)

 

 

 

 

 

 

3.4.13

Outlet RH

0000100.00

...

Enter relative humidity at measuring device

 

 

 

(available if Meter Type =

% Rel.Hum

(compressor outlet)

 

 

FAD meter, see menu

...^

 

 

 

 

 

item 5.4.1, service

 

 

 

 

 

 

 

personnel only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

www.siemens.com/flow

06/2009 - SFIDK.PS.050.F2.02 A5E02100423

Image 60
Contents Page Imprint Contents Contents Technical data Safety Instructions Intended useDevices are particularly suitable for the measurement Devices are rated for the following flow velocitiesCertifications CE markingSafety instructions from the manufacturer Copyright and data protectionDisclaimer Product liability and warranty Information concerning the documentationSafety instructions for the operator Safety warnings are indicated by the following symbolsScope of delivery Instrument versionsDevices come in the following versions Following designs are available as optionsDevices with connection flange Sandwich versionFree air delivery measurement FAD optional Gross heat meter Dual seal Nameplate Storage TransportInstallation Installation condtitionsProhibited installation Measurement of liquidsRecommended installations for measurement of liquids Prohibited installation Measurement of vapours and gasesPipelines with control valve Preferred mounting positionPreferred mounting position Turning the connection housing Allen screws on connection housingTurning the display Turn the display as followsHeat insulation Inlet and outlet runs Minimum inlet runsMinimum outlet runs Flow straightenerInstallation General installation notesInstalling devices in flange design Installing devices in sandwich design Safety instructions Electrical ConnectionsFollowing procedures are to be performed Electrical ConnectionsElectrical connection of current and pulse output Maximum load resistance is calculated as followsPower supply Totalizer / pulse outputElectrical Connections Maximum frequency of the pulse output is fmax = 0.5 HzGrounding connections Protection category Therefore it is essential to observe the following pointsSTART-UP StartStart-up and control Operation Display and operating elementsSwitch from measuring mode to menu mode OperationOperating principles Functional description of the keysChanging the settings in the menu Navigation within the menu structureChanging units Measures in the event of faulty indications Totalizer / pulse outputMax. pulses per hour ExampleVolume Standard volume Mass Liquids, steams, gases Air Gas Overview of the most important functions and unitsLevel Designation Explanation Volume Standard volume Mass Liquids, steams, gases Gas Temp Absolute Power Energy Density Pressure OverError messages Error message Cause MeasureMenu structure Overview of firmware versionsEntering values in change mode Character selection in change modeMenu item Quick Setup Menu item Tests Level Designation Selection / entry ExplanationTest current is maintained until the menu has been exited Menu item Setup firmware version basic Hart SV Operation Menu item Setup firmware version steam Reset heat energy Hart tertiary variable Temp. ↑ Pressure ↑ Density Operation Menu item Setup firmware version gas Hart SV RPM Pressure, temperature and density Operation Replacing signal converter / LCD display Following steps are to be performedService Availability of servicesSpare parts availability Returning the device to the manufacturerForm for copying to accompany a returned device Technical Data Functional principleTechnical data Measuring systemMeasuring accuracy Installation conditions Operating conditionsMaterials Process connections Electrical connectionsApprovals and certifications Dimensions and weights Flange versionsFlange version EN Technical Data Flange version Asme B16.5 NPSSandwich version EN Size Pressure Dimensions inches Weight lbs Rating Sandwich version AsmeWith Without Pressure sensor Flow tables Measuring rangesWater AirFlow rate limits Product Nominal sizes Minimum flow rates Maximum flow ratesFt/s Measuring range saturated steam 1...7 bar Measuring range saturated steam 10.5...20 barKg/h 1092-1Measuring range saturated steam 15...100 psig Measuring range saturated steam 150...300 psigLbs/h Sitrans FX300