Siemens FX300 manual Operating conditions, Installation conditions, Materials

Page 68

8 TECHNICAL DATA

 

 

SITRANS FX300

 

 

 

 

Operating conditions

Temperature

 

 

 

Product

-40…+240°C / -40…+465°F

 

 

Ambient

Non-Ex: -40…+85°C / -40…+185°F

 

 

 

Ex: -40…+60°C / -40…+140°F

 

 

Storage

-50…+85°C / -58…+185°F

 

 

Pressure

 

 

 

Product

Max. 100 bar / 1450 psi; Information on higher pressures on request.

 

 

Ambient

Atmosphere

 

 

Chemical properties

 

 

 

Density

Taken into consideration when sizing.

 

 

Viscosity

< 10 cP

 

 

Reynold's number

10000...2300000

 

 

Recommended flow velocities

 

 

 

Liquids

0.3…7 m/s / 0.98…23 ft/s (optional up to 10 m/s / 32.8 ft/s taking

 

cavitation into account)

Gases and steams

2.0…80 m/s / 6.6…262.5 ft/s

 

DN15: 3.0…45 m/s / 9.8…148 ft/s; DN25: 2.0…70 m/s / 6.6…230 ft/s

 

For detailed information, see chapter "Flow tables".

 

 

Other conditions

 

 

 

Protection category

IP 66/67

 

 

Installation conditions

Inlet run

20 x DN (without disturbing flow, after pipe narrowing, after a single

 

90° bend)

 

 

 

30 x DN (after a double bend 2x90°)

 

 

 

40 x DN (after a double three-dimensional bend 2x90°)

 

 

 

50 x DN (after control valves)

 

 

 

2 DN before flow straightener; 8 DN after flow straightener

 

(specified values apply only to original 20 DN inlet run)

 

 

Outlet run

5 x DN

 

 

Dimensions and weights

For detailed information refer to chapter "Dimensions and weights".

 

 

Materials

Measuring sensor and process

Standard: 1.4404/316L

connections

 

Option: Hastelloy® C-22 on request

 

Converter housing

Die-cast Aluminium

 

 

Pressure sensor gasket

Standard: FPM

 

 

 

Option: FFKM

 

 

Measuring tube gasket

Standard: 1.4435/316L

 

 

 

Option: Hastelloy® C-276

 

Selection depends on measuring sensor material/medium.

 

 

68

www.siemens.com/flow

06/2009 - SFIDK.PS.050.F2.02 A5E02100423

Image 68
Contents Page Imprint Contents Contents Technical data Safety Instructions Intended useDevices are particularly suitable for the measurement Devices are rated for the following flow velocitiesCertifications CE markingDisclaimer Safety instructions from the manufacturerCopyright and data protection Product liability and warranty Information concerning the documentationSafety instructions for the operator Safety warnings are indicated by the following symbolsScope of delivery Instrument versionsDevices come in the following versions Following designs are available as optionsDevices with connection flange Sandwich versionFree air delivery measurement FAD optional Gross heat meter Dual seal Nameplate Storage TransportInstallation Installation condtitionsProhibited installation Measurement of liquidsRecommended installations for measurement of liquids Prohibited installation Measurement of vapours and gasesPreferred mounting position Pipelines with control valvePreferred mounting position Turning the connection housing Allen screws on connection housingTurning the display Turn the display as followsHeat insulation Inlet and outlet runs Minimum inlet runsMinimum outlet runs Flow straightenerInstallation General installation notesInstalling devices in flange design Installing devices in sandwich design Safety instructions Electrical ConnectionsFollowing procedures are to be performed Electrical ConnectionsElectrical connection of current and pulse output Maximum load resistance is calculated as followsPower supply Totalizer / pulse outputElectrical Connections Maximum frequency of the pulse output is fmax = 0.5 HzGrounding connections Protection category Therefore it is essential to observe the following pointsStart-up and control START-UPStart Operation Display and operating elementsSwitch from measuring mode to menu mode OperationOperating principles Functional description of the keysChanging the settings in the menu Navigation within the menu structureChanging units Measures in the event of faulty indications Totalizer / pulse outputMax. pulses per hour ExampleLevel Designation Explanation Volume Standard volume Mass Liquids, steams, gases Air GasOverview of the most important functions and units Volume Standard volume Mass Liquids, steams, gases Gas Temp Absolute Power Energy Density Pressure OverError messages Error message Cause MeasureMenu structure Overview of firmware versionsEntering values in change mode Character selection in change modeMenu item Quick Setup Test current is maintained until the menu has been exited Menu item TestsLevel Designation Selection / entry Explanation Menu item Setup firmware version basic Hart SV Operation Menu item Setup firmware version steam Reset heat energy Hart tertiary variable Temp. ↑ Pressure ↑ Density Operation Menu item Setup firmware version gas Hart SV RPM Pressure, temperature and density Operation Replacing signal converter / LCD display Following steps are to be performedService Availability of servicesSpare parts availability Returning the device to the manufacturerForm for copying to accompany a returned device Technical Data Functional principleMeasuring accuracy Technical dataMeasuring system Materials Installation conditionsOperating conditions Approvals and certifications Process connectionsElectrical connections Flange version EN Dimensions and weightsFlange versions Technical Data Flange version Asme B16.5 NPSSandwich version EN With Without Pressure sensor Size Pressure Dimensions inches Weight lbs RatingSandwich version Asme Flow tables Measuring rangesWater AirFt/s Flow rate limitsProduct Nominal sizes Minimum flow rates Maximum flow rates Measuring range saturated steam 1...7 bar Measuring range saturated steam 10.5...20 barKg/h 1092-1Lbs/h Measuring range saturated steam 15...100 psigMeasuring range saturated steam 150...300 psig Sitrans FX300