Siemens FX300 manual Grounding connections

Page 36

4 ELECTRICAL CONNECTIONS

 

 

SITRANS FX300

 

 

 

 

4.4 Grounding connections

The grounding can be done either by connecting the PE terminal in the housing or the PE terminal on the connection piece between measuring sensor and signal converter. Both of these electrical connections are equally effective from a technical point of view.

Figure 4-5: Grounding connection

1Electrical grounding connection on connection piece between measuring sensor and signal converter.

2Electrical grounding connection on housing

DANGER!

The measuring device has to be grounded properly to achieve accurate measurement. The grounding wire may not transfer any interference voltage.

Do not use this grounding wire to ground any other items of electrical equipment.

36

www.siemens.com/flow

06/2009 - SFIDK.PS.050.F2.02 A5E02100423

Image 36
Contents Page Imprint Contents Contents Technical data Safety Instructions Intended useDevices are particularly suitable for the measurement Devices are rated for the following flow velocitiesCertifications CE markingSafety instructions from the manufacturer Copyright and data protectionDisclaimer Product liability and warranty Information concerning the documentationSafety instructions for the operator Safety warnings are indicated by the following symbolsScope of delivery Instrument versionsDevices come in the following versions Following designs are available as optionsDevices with connection flange Sandwich versionFree air delivery measurement FAD optional Gross heat meter Dual seal Nameplate Storage TransportInstallation Installation condtitionsProhibited installation Measurement of liquidsRecommended installations for measurement of liquids Prohibited installation Measurement of vapours and gasesPipelines with control valve Preferred mounting positionPreferred mounting position Turning the connection housing Allen screws on connection housingTurning the display Turn the display as followsHeat insulation Inlet and outlet runs Minimum inlet runsMinimum outlet runs Flow straightenerInstallation General installation notesInstalling devices in flange design Installing devices in sandwich design Safety instructions Electrical ConnectionsFollowing procedures are to be performed Electrical Connections Electrical connection of current and pulse output Maximum load resistance is calculated as followsPower supply Totalizer / pulse outputElectrical Connections Maximum frequency of the pulse output is fmax = 0.5 HzGrounding connections Protection category Therefore it is essential to observe the following pointsSTART-UP StartStart-up and control Operation Display and operating elementsSwitch from measuring mode to menu mode OperationOperating principles Functional description of the keysChanging the settings in the menu Navigation within the menu structureChanging units Measures in the event of faulty indications Totalizer / pulse outputMax. pulses per hour ExampleVolume Standard volume Mass Liquids, steams, gases Air Gas Overview of the most important functions and unitsLevel Designation Explanation Volume Standard volume Mass Liquids, steams, gases Gas Temp Absolute Power Energy Density Pressure OverError messages Error message Cause MeasureMenu structure Overview of firmware versionsEntering values in change mode Character selection in change modeMenu item Quick Setup Menu item Tests Level Designation Selection / entry ExplanationTest current is maintained until the menu has been exited Menu item Setup firmware version basic Hart SV Operation Menu item Setup firmware version steam Reset heat energy Hart tertiary variable Temp. ↑ Pressure ↑ Density Operation Menu item Setup firmware version gas Hart SV RPM Pressure, temperature and density Operation Replacing signal converter / LCD display Following steps are to be performedService Availability of servicesSpare parts availability Returning the device to the manufacturerForm for copying to accompany a returned device Technical Data Functional principleTechnical data Measuring systemMeasuring accuracy Installation conditions Operating conditionsMaterials Process connections Electrical connectionsApprovals and certifications Dimensions and weights Flange versionsFlange version EN Technical Data Flange version Asme B16.5 NPSSandwich version EN Size Pressure Dimensions inches Weight lbs Rating Sandwich version AsmeWith Without Pressure sensor Flow tables Measuring rangesWater AirFlow rate limits Product Nominal sizes Minimum flow rates Maximum flow ratesFt/s Measuring range saturated steam 1...7 bar Measuring range saturated steam 10.5...20 barKg/h 1092-1Measuring range saturated steam 15...100 psig Measuring range saturated steam 150...300 psigLbs/h Sitrans FX300