6 OPERATION

 

 

 

 

 

 

 

 

 

SITRANS FX300

 

 

 

 

 

 

 

 

 

 

 

 

Level

Designation

Selection / entry

Explanation

 

 

 

 

 

 

 

 

 

(available if Maes.Inst =

kg

 

Select totalizer unit for mass flow measurement

 

 

 

Mass, see menu item

Unit ...^

 

 

 

 

1.1.3)

 

 

 

 

 

 

 

 

0000000000

Enter preset totalizer value

 

 

 

 

 

 

 

 

 

kg ......^

 

 

 

 

 

 

Reset yes /

Reset totalizer /

 

 

 

 

 

Reset no

...^

Do not reset totalizer/

 

 

 

 

 

 

 

 

 

 

Disp. off /

Display totalizer /

 

 

 

 

 

Disp. on

...^

Do not display totalizer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.3

 

 

 

 

HART settings

 

 

 

 

 

 

 

 

3.3.1

Poll. Adr.

000

 

Enter HART polling address for "Multidrop operation"

 

 

 

0 – 15

 

 

 

 

 

 

 

→↑...→↑...^

 

 

 

3.3.2

HART SV

Total Flow ^

HART secondary variable

 

 

 

 

 

 

 

 

 

 

 

 

 

3.3.3

HART TV

Temp. ^

HART tertiary variable

 

 

 

 

 

 

 

 

 

Density ^

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.3.4

HART 4V

Density ^

HART quaternary variable

 

 

 

 

 

 

 

 

 

Temp. ^

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.4

 

 

 

 

Set fluid and medium

 

 

 

 

 

 

 

 

3.4.1

Fluid 1

 

 

Set fluid type

 

 

 

 

 

 

 

 

 

Gas ...

 

Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Liquid. ...

Liquid

 

 

 

 

 

 

 

 

 

 

 

Steam ...^

Steam

 

 

 

 

 

 

 

 

3.4.2

Medium

 

 

Set medium

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(available if Fluid = Gas or

Custom ...

Customer medium

 

 

 

Liquid, see menu item

 

 

 

 

 

 

3.4.1)

 

 

 

 

 

 

 

 

 

 

 

 

(available if Fluid = Steam,

Sat.Steam ...^

Saturated steam

 

 

 

see menu item 3.4.1)

 

 

 

 

 

 

Custom

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 Density check

 

 

 

 

 

 

 

 

 

 

 

 

3.5

 

 

 

 

Set pressure, temperature and density

 

 

 

 

 

 

 

 

3.5.1

T-sensor

 

 

Internal temperature sensor

 

 

 

 

 

 

 

 

 

No ...

 

No temperature sensor available

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes ...^

Temperature sensor available

 

 

 

 

 

 

 

 

3.5.3

Sat.P/T

 

 

Density calculation for saturated steam

 

 

 

 

 

 

 

 

 

Sat. T ^

 

Density calculation for saturated steam with the

 

 

 

(verfügbar wenn FLUID =

 

 

 

 

 

saturated temperature

 

 

 

DAMPF, siehe Menüpunkt

 

 

 

 

3.4.1)

 

 

 

 

 

 

3.5.4

Temp. Opr.

 

 

Operating temperature

 

 

 

 

 

 

 

 

 

°C

 

Set temperature unit

 

 

 

 

 

 

 

 

 

 

Unit ...^

 

 

 

 

 

 

 

 

 

 

 

 

0000000.0

Operating temperature

 

 

 

 

 

°C ^

 

 

 

 

 

 

 

Disp. on /

Display temperature /

 

 

 

 

 

Disp. off

...^

Do not display temperature

 

 

 

 

 

 

 

 

 

52

www.siemens.com/flow

06/2009 - SFIDK.PS.050.F2.02 A5E02100423

Image 52
Contents Page Imprint Contents Contents Technical data Safety Instructions Intended useDevices are particularly suitable for the measurement Devices are rated for the following flow velocitiesCertifications CE markingCopyright and data protection Safety instructions from the manufacturerDisclaimer Product liability and warranty Information concerning the documentationSafety instructions for the operator Safety warnings are indicated by the following symbolsScope of delivery Instrument versionsDevices come in the following versions Following designs are available as optionsDevices with connection flange Sandwich versionFree air delivery measurement FAD optional Gross heat meter Dual seal Nameplate Storage TransportInstallation Installation condtitionsProhibited installation Measurement of liquidsRecommended installations for measurement of liquids Prohibited installation Measurement of vapours and gasesPreferred mounting position Pipelines with control valvePreferred mounting position Turning the connection housing Allen screws on connection housingTurning the display Turn the display as followsHeat insulation Inlet and outlet runs Minimum inlet runsMinimum outlet runs Flow straightenerInstallation General installation notesInstalling devices in flange design Installing devices in sandwich design Safety instructions Electrical ConnectionsFollowing procedures are to be performed Electrical ConnectionsElectrical connection of current and pulse output Maximum load resistance is calculated as followsPower supply Totalizer / pulse outputElectrical Connections Maximum frequency of the pulse output is fmax = 0.5 HzGrounding connections Protection category Therefore it is essential to observe the following pointsStart START-UPStart-up and control Operation Display and operating elementsSwitch from measuring mode to menu mode OperationOperating principles Functional description of the keysChanging the settings in the menu Navigation within the menu structureChanging units Measures in the event of faulty indications Totalizer / pulse outputMax. pulses per hour ExampleOverview of the most important functions and units Volume Standard volume Mass Liquids, steams, gases Air GasLevel Designation Explanation Volume Standard volume Mass Liquids, steams, gases Gas Temp Absolute Power Energy Density Pressure OverError messages Error message Cause MeasureMenu structure Overview of firmware versionsEntering values in change mode Character selection in change modeMenu item Quick Setup Level Designation Selection / entry Explanation Menu item TestsTest current is maintained until the menu has been exited Menu item Setup firmware version basic Hart SV Operation Menu item Setup firmware version steam Reset heat energy Hart tertiary variable Temp. ↑ Pressure ↑ Density Operation Menu item Setup firmware version gas Hart SV RPM Pressure, temperature and density Operation Replacing signal converter / LCD display Following steps are to be performedService Availability of servicesSpare parts availability Returning the device to the manufacturerForm for copying to accompany a returned device Technical Data Functional principleMeasuring system Technical dataMeasuring accuracy Operating conditions Installation conditionsMaterials Electrical connections Process connectionsApprovals and certifications Flange versions Dimensions and weightsFlange version EN Technical Data Flange version Asme B16.5 NPSSandwich version EN Sandwich version Asme Size Pressure Dimensions inches Weight lbs RatingWith Without Pressure sensor Flow tables Measuring rangesWater AirProduct Nominal sizes Minimum flow rates Maximum flow rates Flow rate limitsFt/s Measuring range saturated steam 1...7 bar Measuring range saturated steam 10.5...20 barKg/h 1092-1Measuring range saturated steam 150...300 psig Measuring range saturated steam 15...100 psigLbs/h Sitrans FX300