Hughes & Kettner DUAL EL84, QUAD EL84 Technical Data, Inputs General electrical data, Outputs

Page 13

Statesman Series

5.

Technical Data

All level indications relate to 0 dBV (1V RMS)

Inputs

General electrical data

 

 

INSTRUMENT input

DUAL EL84

QUAD EL84

Jack: spring jack

 

 

 

 

Input design: balanced

Maximum power consumption:

 

 

Input impedance: 1M ohm

130 watts

 

200 watts

 

Sensitivity: -22 dBV / 1 kHz (with Clean, all controllers in middle position)

 

 

 

 

Maximum input level: 1.3 dBV / 1 kHz

Maximum turn-on power consumption (in-rush current)

 

8A @ 240 volts

12A @ 240 volts

FX Return

8A @ 220-230 volts

12A @ 220-230 volts

Jack: spring jack

16A @ 117-120 volts

19A @ 117-120 volts

Input design: balanced

17A @ 100 volts

20A @ 100 volts

Input impedance: 48k ohm

 

 

 

 

Maximum sensitivity: -10 dBV

Range of supply voltage:

 

 

 

+/- 10 %

 

 

 

Outputs

External fuses (anode voltage):

 

 

 

 

 

FX Send

1 x T 250 mA

1 x T 400 mA

Jack: spring jack

 

 

 

 

Output design: balanced

Internal fuses:

 

 

Output impedance: 2k ohm

16 VAC

1 x T 630 mA

16 VAC

1 x T 630 mA

Output level: -10 dBV / 1 kHz (with Clean, all controllers in middle position)

6.3 VAC

1 x T 4A

6.3 VAC

1 x T 5A

Maximum output level: -3 dBV / 1 kHz

 

 

 

 

 

Mains fuse (5 x 20 mm):

 

 

Speaker connection

Europe: (switchable: 220-230 V / 240 V)

 

Spring jack: 1 x 8-16 ohm, parallel to internal speaker

1 x 250 V / T 500 mA

1 x 250 V / T 800 mA

Speaker

USA / Canada / Asia: (switchable: 100 V / 120 V)

1x 12" Eminence Rockdriver Cream, 60 watts, 8 ohm

1 x 250 V / T 1 A

1 x 250 V / T 1,6A

 

Ambient temperature range in operation:

 

 

0 °C to + 35 °C

0 °C to + 35 °C

 

General mechanical data:

 

 

 

Dimensions: (with corners, handles and feet)

 

 

560 x 470 x 250 mm

620 x 490 x 250 mm

 

Weight:

 

 

 

 

19.5 kg

 

21.9 kg

 

english

13

Image 13
Contents Dual EL84 & Quad EL84 Vor der Inbetriebnahme VorwortInbetriebnahme H a L T Anschlüsse und Bedienelemente Röhren, Wartung & Pflege Standard Setup/VerkabelungWas ist beim Röhrentausch zu beachten? Wann ist ein Röhrentausch sinnvoll?Netzanschluss Der Statesman lässt sich nicht einschalten Vorbereitungen und Reihenfolge, unbedingt beachtenSpannungs-Varianten und Spannungsanpassung Eingänge Allgemeine elektrische Daten Technische DatenDual EL84 Quad EL84 AusgängeBefore the start-up ForewordStart-up N T E N T S Foot Switches Channel Select switchConnections & Operating Elements Front side, from right to leftTubes, Servicing & Maintenance Standard Set Up / CablingThings to Bear in Mind When Replacing Tubes When to Replace TubesAvailable Voltages and How to Adapt Them Possible Error Sources / TroubleshootingStatesman is connected properly, but no sound is audible Inputs General electrical data Technical DataOutputs General mechanical dataPuesta en funcionamiento PrólogoDatos Téchnicos N T E N I D O SParte delantera de derecha a izquierda Conexiones y MandosParte trasera de izquierda a derecha Interruptor Channel SelectVálvulas, Mantenimiento y Cuidado Configuración Estándar/Cableado¿Cuándo deben cambiarse las válvulas? ¿Qué debe tenerse en cuenta al cambiar las válvulas?Conexión de red El Statesman no se enciende ¡Realiza los preparativos en el orden descritoEntradas Datos eléctricos generales Datos TéchnicosSalidas Datos mecánicos generalesMise en route PréfaceFiche technique N T E N UFace avant, de droite à gauche Prises et elements de commandeDos, de gauche à droite Interrupteur Channel SelectMontage et cablage standards Lampes, Maintenance & EntretienQuand faut-il remplacer les lampes ? Raccordement secteur le Statesman ne s’allume pas Préparations et ordre, à respecter impérativementVariantes de tension et adaptation de la tension Dual EL84 Fiche techniquePrima della messa in funzione PremessaMessa in funzione D I C E Regolazione Suono Attachi ed Elementi di ComandoInterruttori a Pedale Speaker EsternoTubi, Manutenzione e Pulizia Set up Standard /CablaggioChe cosa devo badare se voglio ricambiare le valvole? Quando si dovrebbero cambiare le valvole?Allacciamento alla rete lo Statesman non si accende Possibili Fonti di Guasto / Ricerca GuastiTensioni disponibili ed adeguamento alle tensioni Entrate Dati elettrici generali Dati TecniciUscite Dati meccanici generaliUnited states Deutsch English Español Francais Italano Hughes & Kettner Statesman Dual EL84 & Quad EL84 Fax +49 68 51 905 200 hkinternational@hughes-and-kettner.com