Omega RD260A instruction manual SET UP Mode

Page 72

Chapter 7 SET UP MODE

This chapter describes the Set Up Mode.

7.1Setting the Output Relay to Energize/De-energize Upon Alarm (option)

7.2Setting Alarm Hysteresis On/Off

7.3Setting the A/D Integration Time (Pen model)

7.4Setting Upscale/Downscale TC Burnout

7.5Configuring the Input Filter (Pen Model)

7.6Setting for Moving Average Calculations (Dot-printing model)

7.7Turning Offset Settings Protection On/Off

7.8Assigning Different Colors to Channels (Dot-printing model)

7.9Setting Pen Offset Compensation On/Off (Pen model, /D1 option)

7.10Turning Alarm Printing On/Off

7.11Setting Periodic Printout On/Off

7.12Turning Printing of Changes in Chart Speed On/Off

7.13Turning Printing of Channel Numbers On/Off (Dot-printing model)

7.14Selecting channel Number or Tag

7.15Changing the Temperature Unit (/D2 option)

7.16Changing Default Settings for REMOTE Operation (option)

7.17Turning the Setting Protection Function On/Off

7.18Initializing Settings

7. SET UP MODE

7 - 1

Image 72
Contents User’s Guide Servicing North America Introduction Power Supply Alternative currentProtective Grounding Necessity of Protective GroundingDefects of Protective Grounding and Fuse FuseInstallation ChaptersContents Setting A/D Integration Time Pen model Before Installation Handling PrecautionsChecking Accessories and Appearance Accessories No. Name Qty RemarksChecking and Unpacking Spare Parts NameRemoving Packings Removing Lock Screw and Packings for TransitChecking Model Codes Checking Model CodesInstallation Site and Mounting Methods Installation SiteMounting Methods MountingExternal Dimensions Panel cutoutWiring Rear Panel Terminal ArrangementPen model Dot-printing modelPower Supply Wiring Power Supply WiringInput Signal Wiring Crimp-On LugsWiring for Input Terminals TC inputRTD input Terminal BoardAlarm Output Wiring option Contact characteristicsOutput type Output capacityRemote Control Wiring option Input characteristicsComponent Names and Functions Power switch push-button type Front PanelKey panel push-key type Chart cassette Status DisplayData Display Characters on the Display Maintenance Switching Power On/OffInstalling or Replacing Chart Paper Prepare a new chart Installing or Replacing Pens Pen model Simple replacementReplacement under pen-replacement mode Felt-tip penPlotter pen Installing or Replacing Ribbon Cassette Dot-printing model Feeding the Chart Getting the RecordingStarting/Stoping the Recording Printing SamplesGetting a Digital Printout Getting a List PrintoutGetting a SET UP List Printout Dot-printing model Printing SampleSelectting the Display Display MAN except for the 1-pen modelSelecting a screen Maintenance Periodic MaintenanceIndication of Remaining Chart Length Battery Replacement Fuse ReplacementCleaning the Carriage Shafts Fuse ReplacementCalibration Pen modelDot-printing model Calibration procedure DC Voltage Signal for Pen model same as Dot-printing modelRequired instruments for calibration Recommended instrumentsTemperature Compensation for Thermocouple Signal Reference Junction Compensation for Thermocouple InputPen-Position Adjustment Pen model Adjusting procedureDaily OPERATION/MAINTENANCE Dot-Position Adjustment Dot-printing model Figure aDaily OPERATION/MAINTENANCE Data Setting Guides Operation mode SET modeSET UP mode Turning the function offOperation Mode Disp keySET Mode SET UP Mode Password Procedures to Enter Setting Data SET Mode Setting Input Range and Recording Span Range Skip Setting Key operationIndication Description Voltage Measurement Setting Volt Setting Volt Input Ranges DisplayKey operation Indication Description TC Type Description and RTD Type DescriptionDigital Input Setting DI Setting Difference Computation Setting Delt Setting Scale Setting SCL Setting Indication DiscriptionSetting to Obtain Square Root Sqrt Setting Key operation Indication DiscriptionENT key Explanation of Square Root Setting Offsets Offst Setting Alarms Alarm Is displayed and the setting is completed. Press Assigning Units Unit Setting Chart Speed Chart Chart Speed unit mm/hSetting Date/Time Clock FIX Auto Assigning Tags TAG Setting Messages MSG Means ‘SPACE’Setting Key-lock KEY SET UP Mode Setting Procedure Setting Alarm Hysteresis On/Off Setting A/D Integration Time Pen model Setting Upscale/Downscale TC Burnout Select Using the key. Press the ENT key Display AppearsConfiguring the Input Filter Pen Model Filter works as followsSetting for Moving Average Calculations Dot-printing model Buffer data forNth sample +1th sample Turning Offset Settings Protection On/Off Assigning Different Colors to Channels Dot-printing model To select Display, and press the ENT key SelectSetting Pen Offset Compensation On/Off Pen model, /D1 option Recorder as Viewed from the SideTurning Alarm Printing On/Off Use Key to select the display Press the ENT keySetting Periodic Printout On/Off Pen Model Chart SpeedDot-printing Model Chart Speed Turning Printing of Changes in Chart Speed On/Off Setting ProcedureSetting Procedure Selecting channel Number or Tag Changing the Temperature Unit /D2 option Select Using the key Press the ENT key. The display AppearsChanging Default Settings for Remote Operation option Turning the Settings Protection Function On/Off Initializing Settings Error Code List Error CodesRecovery Self-diagnostic Message Printout Meanings Store SET UP Settings AgaiinTroubleshooting Recorder is completely inoperativeIs the input free of noise? Glitch is found other than the previously mentioned ploblems Warrant Y/ Disclaimer OMEGA…Of Course