7.10 Turning Alarm Printing On/Off
7.10 Turning Alarm Printing On/Off
When alarms occur, the channel number, level, type of alarm and ON/OFF time can be printed on the right side of the chart. It is selectable to get the ON/OFF time of alarms (ON1), the ON time only (ON2) or to get no printout (OFF). Note that alarms will not be printed when the chart speed exceeds 1800 mm/h (Pen model) or 120 mm/h (Dot- printing model).
The initial value is ‘ON1’, and this setting is common for all channels.
SETTING PROCEDURE:
Enter the SET UP mode by turning ‘ON’ the power while pressing and holding the [CH
UP] (ENT) key until the SET UP display appears.
Use the [ | ] key to select the display [ | ]. Press the [ENT] key. |
Use the [ | ] key to select the display [ | ]. Press the [ENT] key. |
Select ‘ON1’ (ON/OFF time of alarms will be printed), ‘ON2’ (ON time only will be printed) or ‘OFF’ (no alarm will be printed). Press the [ENT] key.
The display [ | ] appears. |
Before leaving the SET UP mode, you have to store your new settings. Use the [ ] key
to select the [ ] display, and press the [ENT] key.
Select [ ] to keep your new settings or [ ] to abort the settings, and press the [ENT] key. After a few seconds, the OPERATION mode will appear.
7. SET UP MODE
7 - 11