Weber 89839 manual Check the Flexible Hose to Manifold Connection, Check for GAS Leaks

Page 9

GAS INSTRUCTIONS

9

 

 

CHECK THE FLEXIBLE HOSE TO MANIFOLD CONNECTION

The natural gas hose has been attached during the manuafacturing process. We do recommend that the hose to gas manifold connnection be leak tested, following guidelines in this Owner’s Guide, prior to barbecue operation.

CHECK FOR GAS LEAKS

DANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. Sparks or open flames will result in a fire or explosion which can cause serious bodily injury or death and damage to property.

WARNING: You should check for gas leaks every time you disconnect and reconnect a gas fitting.

Note: All factory-made connections have been thoroughly checked for gas leaks. The burners have been flame-tested. As a safety precaution however, you should recheck all fittings for leaks before using your Weber® gas barbecue. Shipping and handling may loosen or damage a gas fitting.

WARNING: Perform these leak checks even if your barbecue was dealer or store assembled.

You will need: a soap and water solution, and a rag or brush to apply it.

Make sure side burner is off (See LEAK CHECK PREPARATION). Remove valve control knob and screws. Remove porcelain top.

To perform leak checks: Slide back the collar of the quick disconnect (1). Push male fitting of the hose into the quick disconnect, and maintain pressure. Slide the collar closed (2). If it does not engage or lock, repeat procedure. Gas will not flow unless the quick disconnect is properly engaged.

Turn on gas supply.

Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows, there is a leak.

Note: Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks.

WARNING: Do not ignite burners when leak checking.

Check:

1)Side burner hose to side burner valve connection

2)Hose to manifold connection.

3)Side aburner hose to manifold connection

WARNING: If there is a leak at connection (1), (2) or (3) retighten the fitting with a wrench and recheck for leaks with soap and water solution. If a leak persists after retightening the fitting, turn off the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area using the contact information on our web site.

Log onto www.weber.com®.

4)Valves to manifold connection

5)Hose to quick disconnect connection

WARNING: If there is a leak at connections (4) or (5) turn off the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area using the contact information on our web site.

Log onto www.weber.com®.

When leak checks are complete, turn gas supply off at the source and rinse connections with water.

(1)

(3)

(2)

(4)

(5)

*The grill illustrated may have slight differences than the model purchased.

WWW.WEBER.COM®

Image 9
Contents GAS Grill Liquid Propane GAS Units only Wash hands after handling this productWarranty Garantía GARANTIE3 Customer Service Center Roselle Road, Suite Schaumburg, ILPara partes de repuesto llame a Exploded View Diagrama DE Despiece Vision Éclatée Exploded List Lista DEL Diagrama Liste DE LA Vision Éclatée General Instructions GAS Instructions Install GAS SupplyGAS Line Piping Test ConnectionsPortable Installation What is Natural GAS?Type of GAS Leak Check PreparationCheck for GAS Leaks Check the Flexible Hose to Manifold ConnectionOperating Instructions LightingMain Burner Lighting Manual Lighting To ExtinguishLighting the Side Burner Troubleshooting Problem Check CureManually Lighting the Side Burner Side Burner Maintenance Sideburner TroubleshootingAnnual Maintenance MaintenanceMain Burner Cleaning Procedure Weber Spider /INSECT ScreensCrossover Ignition System Operations Replacing Main BurnersBarbacoa DE GAS Peligro Peligros Y AdvertenciasAdvertencias Únicamente Unidades DE GAS Propano LicuadoAlmacenaje Instrucciones GeneralesOperación CocciónInstale EL Suministro DE GAS Instrucciones Sobre EL GASInstalación DE LA Tubería DE GAS Prueba DE LAS Conexiones¿QUÉ ES EL GAS NATURAL? Tipo DE GASInstalación Transportable Preparativos Para LA Búsqueda DE FugasRevise LA Manguera Flexible a LA Conexión DEL Múltiple Compruebe QUE no Haya Fugas DE GAS PeligroComprobación Instrucciones DE Operación EncendidoEncendido DEL Quemador Principal Encendido Manual Peligro Para ApagarCómo Encender EL Quemador Lateral Peligro Resolución DE Problemas Problema Revisar RemedioEncendido Manual DEL Quemador Lateral Peligro Mantenimiento DEL Quemador Lateral Weber Mallas Contra ARAÑAS/INSECTOS MantenimientoMantenimiento Anual Patrón DE LA Llama DEL Quemador PrincipalOperación DEL Sistema DE Encendido Crossover Reemplazo DE LOS Quemadores PrincipalesGrill a GAZ Appareils a GAZ Propane Uniquement Mises EN GardeInstructions Générales Instructions Pour LE GAZ Installation DE L’ALIMENTATION EN GAZContrôle DES Raccords Tuyauterie DE Canalisation DE GAZRetirer LE Panneau DE Commande ET LES Manettes DE Réglage Installation PortativeType DE GAZ QU’EST-CE QUE LE GAZ Naturel ?Vérifiez Detection DES Fuites DE GAZMode D’EMPLOI AllumageAllumage DU Bruleur Principal Allumage Manuel ExtinctionAllumage DU Bruleur Lateral Problème Vérification Solution DépannageAllumage Manuel DU Bruleur Lateral Maintenance DU Bruleur Lateral Probleme Verification SolutionÉcrans PARE-ARAIGNÉES/INSECTES EntretienInspection ET Nettoyage DES Écrans PARE-ARAIGNÉES/ Insectes Flamme DES Brûleurs PrincipauxFonctionnement DU Système D’ALLUMAGE Crossover Remplacement DES Brûleurs PrincipauxPage Page WEBER-STEPHEN Products CO By e-mail / Por correo electrónico / Par e-mail Pour les achats effectués aux États-Unis For purchases made in the U.SFor purchases made in Mexico Para compras hechas en México