Teledyne AX300-I manual Options, Digit LCD display. For RS-232 reconfiguration, see Section

Page 11

Portable Oxygen Analyzer

Introduction

 

 

 

Microprocessor controlled

Sensor fail/disconnect alarm indicator (audible and visual)

Alarm silence button

2000 operating hours from 3 AA alkaline batteries

Battery status indicator

Stand for upright tabletop deployment

Hardware for pole clamping and V block support

Rugged high impact ABS construction

Splash resistant case.

Long life (36 months in air) class R17MED sensor

0-1 VDC digital output (optional RS-232)

FDA approved and cleared for CSA/CE marking

1.3Options

The following instrument options are available for the AX 300-I analyzer:

A-Option—3-digit LCD display instead of 3 1/2 digit

B-Option—RS 232 digital output instead of 0-1VDC

Note: Contact the factory for retrofitting an existing instrument for

3 digit LCD display. For RS-232 reconfiguration, see Section 2.1.5.

In addition to the above instrument configuration options, the following optional equipment is available for your instrument:

Universal Pole Mounting Clamp (P/N CP 2343)

V-Mount Pole Clamp (P/N CP 2344)

V-Mount Wall Adapter P/N B 647)

0-1 VDC Interface Cable (P/NB-75554)

RS 232 Interface Cable (P/N B-75555)

Teledyne Analytical Instruments

11

Image 11
Contents AX300-I AX300-I About This Manual How To Use This ManualSafety Messages Table of Contents Index Teledyne Analytical Instruments AX300 Front View List of Figures List of Tables AX300 Front View IntroductionApplicable Standards FeaturesOptions Digit LCD display. For RS-232 reconfiguration, see SectionSensor ApplicationsTheory of Operation Signal Processing Operation SetupInstalling the R17MED Sensor Sensor Installation or ReplacementSensor Cable Connection to Analyzer MountingV-Mount Adapter Installation Battery InstallationInstalling Batteries Calibration S CalibrationOperation AX300-I 0-1 VDC or RS 232 Digital Output Port Output 0-1 VDC or RS232Use ProcedurePortable Oxygen Analyzer Operation Pressure TemperatureGas Sampling HumidityAnesthetic Gases Discrepancy in ReadingsOperation AX300-I Oxygen Reading Error in a Mixture of Anesthetic Gas Do’s and Don’ts CleaningPortable Oxygen Analyzer Operation Blank Battery Maintenance General Service InformationOverall Maintenance Calibration Sensor MaintenanceHumidity Discrepancy in Readings Oxygen Reading Error Troubleshooting Troubleshooting√ Sensor Concentration of O2 is Watchdog Error CodesOther Problems with the Instrument Appendix Return Authorization for ServiceSpecifications Appendix AX300-I Optional Accessories Spare Parts ListInstrument for which the parts are intended Blank Index Index