Teledyne AX300-I manual Appendix, Return Authorization for Service, Specifications

Page 41

Portable Oxygen Analyzer

Appendix

 

 

 

a problem with your instrument to Teledyne Customer Service. If an error code is indicated on your analyzer record the number and report it to the Customer Service Department at the address below.

3.10 Return Authorization for Service

For any service beyond sensor and battery replacement, the instrument must be returned to the factory. A return merchandise authorization (RMA) number must be obtained from Teledyne Analytical Instruments prior to returning an instrument for service. You can request a RMA number via email by contacting us at:

tetci_customerservice@teledyne.com You can also contact us at the address below.

Customer Service Department

TELEDYNE Analytical Instruments

16830 Chestnut Street

City of Industry, CA 91749-1580 USA

Phone (626) 934-1500, Fax (626) 961-2538 Or via the web at: www.teledyne-ai.com

Appendix

A.1 Specifications

Range:

0-100% oxygen

Accuracy:

+2% of full scale (at constant temperature

 

and pressure)

Response Time:

90% in less than 8 seconds at 25 °C

Battery Life:

Approximately 2000 hr. continuous use in

 

a non-alarm condition

System Power:

3 AA alkaline batteries.

Sensor Type:

Class R17MED

Teledyne Analytical Instruments

41

Image 41
Contents AX300-I AX300-I About This Manual How To Use This ManualSafety Messages Table of Contents Index Teledyne Analytical Instruments AX300 Front View List of FiguresList of Tables AX300 Front View IntroductionApplicable Standards FeaturesOptions Digit LCD display. For RS-232 reconfiguration, see SectionSensor ApplicationsTheory of Operation Signal Processing Operation SetupInstalling the R17MED Sensor Sensor Installation or ReplacementSensor Cable Connection to Analyzer MountingV-Mount Adapter Installation Battery InstallationInstalling Batteries Calibration S CalibrationOperation AX300-I 0-1 VDC or RS 232 Digital Output Port Output 0-1 VDC or RS232Use ProcedurePortable Oxygen Analyzer Operation Gas Sampling TemperatureHumidity PressureAnesthetic Gases Discrepancy in ReadingsOperation AX300-I Oxygen Reading Error in a Mixture of Anesthetic Gas Do’s and Don’ts CleaningPortable Oxygen Analyzer Operation Blank Battery Maintenance General Service InformationOverall Maintenance Calibration Sensor MaintenanceHumidity Discrepancy in Readings Oxygen Reading Error Troubleshooting Troubleshooting√ Sensor Concentration of O2 is Watchdog Error CodesOther Problems with the Instrument Appendix Return Authorization for ServiceSpecifications Appendix AX300-I Optional Accessories Spare Parts ListInstrument for which the parts are intended Blank Index Index